Notifier FCPS-24E

Remote charger power supply (220/240 VAC)

  • Material Obsolete
Brand: Notifier FireAlarm.com Part #: 52516 Category: Manufacturer Part #: FCPS-24E

Description

The NOTIFIER FCPS-24 (120 VAC model) and FCPS-24E (220/240 VAC model) are compact, cost-effective, 6-amp remote power supplies with built-in battery charger. The FCPS-24(E) may be connected to any 12- or 24-volt Fire Alarm Control Panel (FACP) or may stand alone. Primary applications include Notification Appliance (bell) Circuit (NAC) expansion (to support ADA requirements) or auxiliary power to support 24-volt system accessories. The FCPS provides regulated and filtered 24 VDC power to four Notification Appliance Circuits (two Class A [Style Z] and two Class B [Style Y] or four Class B only). Alternately, the four outputs may be configured as any combination of resettable/non-resettable power outputs (optimal for powering four-wire smoke detectors). The FCPS-24(E) also contains a battery charger capable of charging up to 7.0 Amp Hour batteries.

Information

Weight 12.00 lbs
Dimensions 2.75 × 14.50 × 15.00 in
Color

Production Status

Brand

Product Notes

Replacement: HPF-PS6E

Features

  • Requires input trigger voltage of 9.0 – 32 VDC.
  • Contains two, fully-isolated input/control circuits (triggered from FACP Notification Appliance Circuit [NAC expander mode] or jumpered permanently on [stand-alone mode]).
  • Two Class A (Style Z) or Class B (Style Y) Notification Appliance Circuits (circuits 1 & 3).
  • Two additional NACs that may be individually configured for Class B (Style Y) operation only (circuits 2 & 4).
  • 6 Amp full load output (3 amps max./ckt.) in NAC expander mode (UL 864).
  • 4 Amp continuous output in stand-alone mode (UL1481).
  • In stand-alone mode, output power circuits may be configured as resettable (reset line from FACP required) or non-resettable.
  • Fully regulated and filtered power output (optimal for powering four-wire smoke detectors, annunciators and other system peripherals requiring regulated/filtered power).
  • Fuseless, power-limited technology meets new UL power-limiting requirements, effective May 1, 1995.
  • Normally closed trouble contact.
  • Fully supervised power supply, battery and Notification Appliance Circuits.
  • Selectable earth fault detection.
  • AC trouble reports electable for immediate, 8- or 16-hour delay.
  • Optional ammeter/voltmeter.
  • Works with virtually any UL 864 fire alarm control which utilizes an industry-standard reverse-polarity notification circuit.
  • Self-contained in compact, lockable cabinet (15″ [381 mm] high x 14.5″ [368 mm] wide x 2.75″ [70 mm] deep).
  • Includes integral battery charger capable of charging up to 7.0 AH batteries.
  • Fixed, clamp-type terminal blocks accommodate up to 12 AWG (3.25 mm2) wire.

FCPS-24(E); 24 Volt, 6 Amp Remote Power Supply

Download

Notifier - Data Sheet

FCPS-24/FCPS-24E; Field Charger/Power Supply

Download

Notifier - Installation Manual