Potter PAD100-PHD

Photoelectric Smoke & Heat Sensor

Condition: New
Brand: Potter
Status: Obsolete
SKU: 41529
Manufacturer Part #: PAD100-PHD
Secondary Part #: 3992734
Replacement: PAD200-PHD

Description

The PAD100-PHD is a listed Analog Addressable smoke sensor and a rate of rise and/or fixed temperature heat sensor compatible with fire alarm control panels that utilize the Potter Addressable Device (PAD) protocol. The PAD100-PHD is a low profile smoke/heat sensor with a wide sensitivity range. The heat sensing portion utilizes a proven thermistor for accurate and reliable heat detection. The sensor and base (not included) are made of a durable plastic in an off-white color to blend in with the ceiling. The PAD100-PHD is UL listed and has a sensitivity range of 1.0 to 3.5% per foot with a fix temperature alarm threshold of 135°F and can be used for rate of rise applications. See detector spacing limitations below. The PAD100-PHD features drift compensation and has built in dirty detector warning. The PAD100-PHD and the control panel communicate over a proven and robust digital communication path and the system analyzes the information at the particular device. The total polling speed is less than five (5) seconds, well under the UL requirements. The sensor is compatible with any of the PAD series sensor bases and simply twists on. The PAD100-PHD is addressed using DIP switches in the rear of the sensor and can be easily programmed in the field without special tools.

Additional information

Weight 0.2 lbs
Dimensions 3.93 × 3.93 × 1.94 in
Manufacturer

Potter Electric Signal Company, LLC

Brand

Condition

New

Unit of Measurement

EA (Each)

Programming

DIP Switch

Detection Method

Fixed Temperature, Photoelectric, Programmable, Rate-of-Rise

Thermal Rating

135°F

Production Status

Obsolete

Series

Features

  • Selectable Rate of Rise and/or Fixed Heat Detector
  • Reliable detection technology
  • Wide selectable smoke sensitivity range of 1.0 to 3.5%/foot
  • Sensor communicates sensitivity to control panel
  • UL listed smoke calibration and sensitivity
  • Ambient temperature listing of 32 ° F to 150 ° F
  • Optional locking tab to prevent unwanted removal
  • Simple DIP switch address setting, no programming tool required
  • LED alarm indicator
  • UUKL Listed for Smoke Control

PAD100-PHD; Photoelectric Smoke/Heat Detector Combination

Download

Potter - Data Sheet

Installation Manual Detector Bases; PAD100-6DB & PAD100-4DB

Download

Potter - Installation Manual