Fireye BP230UV-S1

$706.76

BurnerPRO Single Burner Control, 230VAC 50/60Hz, Series 1 timings, with UV non-self check amplifier, IP40

Availability: Please Call for Availability
Condition: New
Brand: Fireye
Status: Active
SKU: 179807
Manufacturer Part #: BP230UV-S1
Compatible with 60-2981-1 and Siemens LFL wiring base

Description

The Fireye BurnerPRO is a compact, microprocessor-based, primary flame safeguard control system designed to provide the proper burner sequencing, ignition, and continuous flame monitoring for on-off, multi-stage, or modulating burners used in commercial heating and process equipment firing oil and gas fuels. The system is designed for use in non-permanent operations that require burner recycle at least once every 24 hours. Flame monitoring for the UV version is accomplished by the built-in amplifier and compatible UV scanner. Control functions and timings are factory-set via unique microcontroller firmware. Through seven SMART LEDs, the control provides current operating status and lockout information in the event of a safety shutdown. Refer to the BurnerPRO ordering information section later in this document for the various combinations of control functions and timings. A complete BurnerPRO system includes the BP110/230, flame scanner, and wiring base. The BurnerPRO performs a safety self-test on every start. If a flame is detected prior to a start or during the purge cycle, the fuel valves are not energized and the control locks out. The LEDs and alarm terminal are used to annunciate the presence of a lockout condition.

Documents

Description

The Fireye BurnerPRO is a compact, microprocessor-based, primary flame safeguard control system designed to provide the proper burner sequencing, ignition, and continuous flame monitoring for on-off, multi-stage, or modulating burners used in commercial heating and process equipment firing oil and gas fuels. The system is designed for use in non-permanent operations that require burner recycle at least once every 24 hours.

Flame monitoring for the UV version is accomplished by the built-in amplifier and compatible UV scanner. Control functions and timings are factory-set via unique microcontroller firmware. Through seven SMART LEDs, the control provides current operating status and lockout information in the event of a safety shutdown. Refer to the BurnerPRO ordering information section later in this document for the various combinations of control functions and timings.

A complete BurnerPRO system includes the BP110/230, flame scanner, and wiring base. The BurnerPRO performs a safety self-test on every start. If a flame is detected prior to a start or during the purge cycle, the fuel valves are not energized and the control locks out. The LEDs and alarm terminal are used to annunciate the presence of a lockout condition.

Additional information

Weight 2.5 lbs
Dimensions 4.15 × 4.15 × 5.00 in
Manufacturer

Fireye

Brand

Condition

New

Unit of Measurement

EA (Each)

Production Status

Active

Reviews

There are no reviews yet.

Be the first to review “Fireye BP230UV-S1”

FIREYE BurnerPRO

Download

Fireye - Manual

Attributes

Weight 2.5 lbs
Dimensions 4.15 × 4.15 × 5.00 in
Manufacturer

Fireye

Brand

Condition

New

Unit of Measurement

EA (Each)

Production Status

Active

Product Features

  • Non-volatile lockout capability
  • Proof of fuel valve closure
  • Air-flow proving
  • A run/check feature allows the operator to stop the program sequence in different positions (Purge, Ignition, PTFI and MTFI)
  • Remote and local Reset
  • One second flame failure response time
  • Smart LEDs provide on board diagnostic lockout information
  • Real-time internal diagnostics for added safety integrity
  • Extended temperature operation (-40°C to 60°C) with an over-temp inhibit feature
  • High capacity relay contacts

What's Included

Shipping Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1 – 5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock. PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client.

Return Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee. New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made. See our complete return policy for more information at: https://firealarm.com/faq/

Testimonials

Rick A.
Dallas, TXI
Read More
"Great service. I received help with exactly what I needed and I received it all in a timely manner."
Charles O.
New Brunswick, NJ
Read More
"I had a big engineering/logistics issue that William over at FireAlarm.com helped me with. I don’t know what I would’ve done without their help!"
Jason G.
Los Angeles, CA
Read More
"The fastest delivery I’ve seen. Needed overnight emergency parts and I got just that."
Julia S.
Tampa, FL
Read More
"Needed last-minute maintenance done on my building’s system, and FireAlarm.com exceeded my expectations with how quickly it was done."

Leave a review

Reviews

There are no reviews yet.

Be the first to review “Fireye BP230UV-S1”

Pricing & Availability Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1 – 5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock. PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client.

Payment Details

You may remit payment via a US-Based Credit Card (CC Authorization Form), Wire Transfer (w/ $30 or $50 fee added to invoice), via PayPal (Or PayPal Pay Later), via Apple or Google Pay, or by mailing us a check. You can also call in with your credit card information at any time: 888-497-0290.

Return & Cancellation Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee. New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made. See our complete return policy for more information at: https://firealarm.com/faq/