Fireye VFS-2000-K15

$8,552.70

Fireye Turbine Sensor KIT, Fiber optic length 15ft or 4.6 meter

Availability: Please Call for Availability
Condition: New
Brand: Fireye
Status: Active
SKU: 180491
Manufacturer Part #: VFS-2000-K15
Note: Cable to be ordered separately

Description

The Fireye VFS-2000 Turbine Sensor is designed to sense flame in extreme high-pressure and hot environments, such as those found on turbine generators in power generation facilities. Similar challenging environments can be found near steam boilers, waste incinerators, down-fired reformer furnaces, ground flares, rotary kiln systems, ovens, and dryers in power generation facilities, oil refineries, petrochemical, ammonia plants, paper and pulp industries. The VFS-2000 Turbine Flame Sensor responds to ultraviolet optical energy from the flame (200-400 nanometers) and has a loop-powered 4-20mA output representing flame brightness from a very low level. It is not sensitive to visible and IR emissions from hot walls. The Fireye design basis is a total separation of the optical sensing device from the turbine without the need for expensive water or pressurized air cooling systems.

Documents

Description

The Fireye VFS-2000 Turbine Sensor is designed to sense flame in extreme high-pressure and hot environments, such as those found on turbine generators in power generation facilities. Similar challenging environments can be found near steam boilers, waste incinerators, down-fired reformer furnaces, ground flares, rotary kiln systems, ovens, and dryers in power generation facilities, oil refineries, petrochemical, ammonia plants, paper and pulp industries.

The VFS-2000 Turbine Flame Sensor responds to ultraviolet optical energy from the flame (200-400 nanometers) and has a loop-powered 4-20mA output representing flame brightness from a very low level. It is not sensitive to visible and IR emissions from hot walls. The Fireye design basis is a total separation of the optical sensing device from the turbine without the need for expensive water or pressurized air cooling systems.

Additional information

Weight 6 lbs
Manufacturer

Fireye

Brand

Condition

New

Unit of Measurement

EA (Each)

Production Status

Active

Reviews

There are no reviews yet.

Be the first to review “Fireye VFS-2000-K15”

Turbine Sensor VFS-2000

Download

Fireye - Data Sheet

VFS-2000 Turbine Flame Sensor

Download

Fireye - Manual

Attributes

Weight 6 lbs
Manufacturer

Fireye

Brand

Condition

New

Unit of Measurement

EA (Each)

Production Status

Active

Product Features

  • Solid state design, no tubes or shutters.
  • Detects hydrogen, natural gas or fuel oil turbine
  • Silicon carbide UV spectrum sensor, fast response time
  • Installs with ¾ inch NPT standard gas turbine pipe
  • Compact design, removable without turbine interruptions

What's Included

Shipping Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1 – 5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock. PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client.

Return Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee. New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made. See our complete return policy for more information at: https://firealarm.com/faq/

Testimonials

Rick A.
Dallas, TXI
Read More
"Great service. I received help with exactly what I needed and I received it all in a timely manner."
Charles O.
New Brunswick, NJ
Read More
"I had a big engineering/logistics issue that William over at FireAlarm.com helped me with. I don’t know what I would’ve done without their help!"
Jason G.
Los Angeles, CA
Read More
"The fastest delivery I’ve seen. Needed overnight emergency parts and I got just that."
Julia S.
Tampa, FL
Read More
"Needed last-minute maintenance done on my building’s system, and FireAlarm.com exceeded my expectations with how quickly it was done."

Leave a review

Reviews

There are no reviews yet.

Be the first to review “Fireye VFS-2000-K15”

Pricing & Availability Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1 – 5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock. PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client.

Payment Details

You may remit payment via a US-Based Credit Card (CC Authorization Form), Wire Transfer (w/ $30 or $50 fee added to invoice), via PayPal (Or PayPal Pay Later), via Apple or Google Pay, or by mailing us a check. You can also call in with your credit card information at any time: 888-497-0290.

Return & Cancellation Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee. New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made. See our complete return policy for more information at: https://firealarm.com/faq/