Description

The Fireray® 2000 EExd system is ideally suited to protect large areas with potentially explosive atmospheres, protection against smoking fires can be provided by this beam. Fireray® 2000 EExd includes an infrared transmitter and a receiver, both of which are ATEX-certified for use in Group 2 hazardous areas. There is a separate, safe area, wall-mounted remote low level control unit to allow adjustment and testing from a convenient non-hazardous location.

The product is designed for large enclosures with oil rigs, refineries, ordnance stores, waste water treatment plants, and similar premises. It provides an early warning of smoldering smoke generated fires, some of which may not be picked up by flame detectors installed in many hazardous areas. For installations complying with UL268/NFPA72, the maximum distance of Detector and Reflector from the ceiling must be 10% of the distance between floor and ceiling.

Documents

Description

The Fireray® 2000 EExd system is ideally suited to protect large areas with potentially explosive atmospheres, protection against smoking fires can be provided by this beam. Fireray® 2000 EExd includes an infrared transmitter and a receiver, both of which are ATEX-certified for use in Group 2 hazardous areas. There is a separate, safe area, wall-mounted remote low level control unit to allow adjustment and testing from a convenient non-hazardous location.

The product is designed for large enclosures with oil rigs, refineries, ordnance stores, waste water treatment plants, and similar premises. It provides an early warning of smoldering smoke generated fires, some of which may not be picked up by flame detectors installed in many hazardous areas. For installations complying with UL268/NFPA72, the maximum distance of Detector and Reflector from the ceiling must be 10% of the distance between floor and ceiling.

Additional information

Weight 10.2 lbs
Dimensions 3.50 × 8.50 × 10.30 in
Manufacturer

Halma

Brand

Condition

New

Unit of Measurement

EA (Each)

Production Status

Active

Reviews

There are no reviews yet.

Be the first to review “Fireray 2000 EExd”

Fireray 2000 EExd; Explosion Proof Optical Beam Smoke Detector

Download

Fireray - Data Sheet

Fireray 2000 EExd; Hazardous Area Smoke Detector

Download

Fireray - Installation Guide

Attributes

Weight 10.2 lbs
Dimensions 3.50 × 8.50 × 10.30 in
Manufacturer

Halma

Brand

Condition

New

Unit of Measurement

EA (Each)

Production Status

Active

Product Features

  • Separate explosion-proof Transmitter and Receiver units
  • Signal Strength indicating LED’s
  • Range 33ft. to 330ft. (10m to 100m)
  • Easy set up and alignment
  • Internal test switch
  • Complies with ATEX and EN54:12
  • 3 selectable fire alarm thresholds: 25%, 35% or 50%
  • Alarm latching or auto reset
  • Automatic Gain Control (AGC)
  • 12 VDC or 24 VDC operation
  • Separate alarm and trouble relay contacts
  • Ground Level Control unit
  • Adjustment using wall bracket
  • Built-in 1/2”/M-20 conduit knock-outs on controller.
    • M-10 threaded on TX/RX.

What's Included

Shipping Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1 – 5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock. PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client.

Return Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee. New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made. See our complete return policy for more information at: https://firealarm.com/faq/

Testimonials

Rick A.
Dallas, TXI
Read More
"Great service. I received help with exactly what I needed and I received it all in a timely manner."
Charles O.
New Brunswick, NJ
Read More
"I had a big engineering/logistics issue that William over at FireAlarm.com helped me with. I don’t know what I would’ve done without their help!"
Jason G.
Los Angeles, CA
Read More
"The fastest delivery I’ve seen. Needed overnight emergency parts and I got just that."
Julia S.
Tampa, FL
Read More
"Needed last-minute maintenance done on my building’s system, and FireAlarm.com exceeded my expectations with how quickly it was done."

Leave a review

Reviews

There are no reviews yet.

Be the first to review “Fireray 2000 EExd”

Pricing & Availability Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1 – 5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock. PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client.

Payment Details

You may remit payment via a US-Based Credit Card (CC Authorization Form), Wire Transfer (w/ $30 or $50 fee added to invoice), via PayPal (Or PayPal Pay Later), via Apple or Google Pay, or by mailing us a check. You can also call in with your credit card information at any time: 888-497-0290.

Return & Cancellation Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee. New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made. See our complete return policy for more information at: https://firealarm.com/faq/