Edwards EST FSP1004R

$582.77

Conventional Fire Alarm Control Panel – 10 Class B IDCs and 4 Class B NACs, 120 Vac

Availability: In Stock
Condition: New
Brand: Edwards, EST
Status: Active
SKU: 43568
Manufacturer Part #: FSP1004R

Description

The FireShield Plus fire alarm family consists of 3, 5 and 10 zone conventional fire alarm control panels, an integrated DACT/Dialer, serial annunciator modules, and serial remote relay modules. All of these components are microprocessor-controlled. The FireShield Plus family is ideal for both new and retrofit installations alike.

FireShield Plus incorporates features designed to simplify installation, operation and maintenance. These include front panel programming, one person walk testing, and selectable IDC and NAC types. In addition, when used with Edwards CleanMe® -compatible smoke detectors, FireShield Plus provides analog type features such as remote maintenance alert and automatic drift compensation that reduce false alarms and simplify maintenance calls.

FSP502 and FSP1004 panels support Class A operation by combining pairs of on-board initiating circuits (IDCs) or notification circuits (NACs) to provide the necessary Class A circuits. For example, the FSP1004 comes factory set to support 10 Class B IDCs and four NACs. But it can be field-configured to provide five Class A IDCs, no Class B IDCs, and two Class A NACs – or any other combination of circuits that fall within the circuit-pairing parameters.

Documents

Description

The FireShield Plus fire alarm family consists of 3, 5 and 10 zone conventional fire alarm control panels, an integrated DACT/Dialer, serial annunciator modules, and serial remote relay modules. All of these components are microprocessor-controlled. The FireShield Plus family is ideal for both new and retrofit installations alike.

FireShield Plus incorporates features designed to simplify installation, operation and maintenance. These include front panel programming, one person walk testing, and selectable IDC and NAC types. In addition, when used with Edwards CleanMe® -compatible smoke detectors, FireShield Plus provides analog type features such as remote maintenance alert and automatic drift compensation that reduce false alarms and simplify maintenance calls.

FSP502 and FSP1004 panels support Class A operation by combining pairs of on-board initiating circuits (IDCs) or notification circuits (NACs) to provide the necessary Class A circuits. For example, the FSP1004 comes factory set to support 10 Class B IDCs and four NACs. But it can be field-configured to provide five Class A IDCs, no Class B IDCs, and two Class A NACs – or any other combination of circuits that fall within the circuit-pairing parameters.

Additional information

Weight 16 lbs
Dimensions 3.75 × 15.00 × 30.00 in
Condition

New

Color

Red

Series

Brand

,

Production Status

Active

Reviews

There are no reviews yet.

Be the first to review “Edwards EST FSP1004R”

EST FireShield Plus Data Sheet

Download

Edwards - Data Sheet

FireShield Plus Fire Alarm Control Panel Operating Instructions

Download

Edwards - Installation Instructions

Attributes

Weight 16 lbs
Dimensions 3.75 × 15.00 × 30.00 in
Condition

New

Color

Red

Series

Brand

,

Production Status

Active

Product Features

  • Available in 3, 5, and 10 IDC models
  • IDC or NAC pairs convertible to single Class A circuits (10 and 5 IDC panels only)
  • CleanMe® provides remote annunciation if a detector drifts out of UL/ULC limits reducing the chance of a false alarm
  • Combination Waterflow and Supervisory IDCs reduces wire and zone counts
  • NACs programmable by zone and individually selectable for Genesis, continuous, temporal outputs, or coded
  • Front panel programmable simplifies installation and servicing
  • Optional fully integrated DACT/Dialer for PC programming
  • Genesis option allows precision synchronization and audible silence over two wires without additional modules
  • On-board relays for Alarm, Supervisory and Trouble
  • Optional serial bus relay modules are programmable for common or zone activation
  • Optional serial bus remote annunciator family
  • One person walk-test (audible or silent)
  • Expandable power supply on 10 IDC panel reduces booster power costs
  • Trim ring available for semi-flush mounting
  • Supports 2M, “EC”, 6200, 400, 500 and 700 series detectors

What's Included

Shipping Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1 – 5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock. PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client.

Return Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee. New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made. See our complete return policy for more information at: https://firealarm.com/faq/

Testimonials

Rick A.
Dallas, TXI
Read More
"Great service. I received help with exactly what I needed and I received it all in a timely manner."
Charles O.
New Brunswick, NJ
Read More
"I had a big engineering/logistics issue that William over at FireAlarm.com helped me with. I don’t know what I would’ve done without their help!"
Jason G.
Los Angeles, CA
Read More
"The fastest delivery I’ve seen. Needed overnight emergency parts and I got just that."
Julia S.
Tampa, FL
Read More
"Needed last-minute maintenance done on my building’s system, and FireAlarm.com exceeded my expectations with how quickly it was done."

Leave a review

Reviews

There are no reviews yet.

Be the first to review “Edwards EST FSP1004R”

Pricing & Availability Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1 – 5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock. PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client.

Payment Details

You may remit payment via a US-Based Credit Card (CC Authorization Form), Wire Transfer (w/ $30 or $50 fee added to invoice), via PayPal (Or PayPal Pay Later), via Apple or Google Pay, or by mailing us a check. You can also call in with your credit card information at any time: 888-497-0290.

Return & Cancellation Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee. New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made. See our complete return policy for more information at: https://firealarm.com/faq/