Honeywell IFP-300

$1,646.60

Intelligent Fire Alarm Control Panel, Red Cabinet

Availability: Please Call for Availability
Condition: New
Brand: Farenhyt, Silent Knight
Status: Active
SKU: 47206
Manufacturer Part #: IFP-300

Description

The IFP-300 (red) and IFP-300B (black) are intelligent analog/addressable Fire Alarm Control Panels (FACP). The basic IFP-300 panel contains one built in signaling line circuit (SLC), which can support 159 IDP/SK sensors and 159 IDP/SK modules or 127 SD devices per loop. Additional SLC loops can be added using the model 6815 SLC expander for System Sensor devices to increase the overall point capacity to a maximum of 300 points per panel, or model 5815XL for Hochiki devices to increase the overall point capacity to a maximum of 254 points per panel.

IFP-300 has the interconnection capability for up to 32 panels. The system has two modes of operation, multiple panels covering one larger building, or multiple independent buildings. To network panels together use the SK-NIC network interface card. Copper wire or fiber optic cable panel connectivity can be used within the same networked system.

IFP-300 has a built-in dual phone line, digital alarm communicator/ transmitter (DACT), IP or optional cellular technologies, Form C trouble relay, and two programmable Form C relays. IFP-300 has powerful features such as detector sensitivity, day/night thresholds, drift compensation, pre-trouble maintenance alert, and calibration trouble alert.

The IFP-300 supports a variety of devices, including RA-2000, RA-1000 or RA-100 remote annunciator, 5824 serial/ parallel printer interface module (for printing system reports).

Documents

Description

The IFP-300 (red) and IFP-300B (black) are intelligent analog/addressable Fire Alarm Control Panels (FACP). The basic IFP-300 panel contains one built in signaling line circuit (SLC), which can support 159 IDP/SK sensors and 159 IDP/SK modules or 127 SD devices per loop. Additional SLC loops can be added using the model 6815 SLC expander for System Sensor devices to increase the overall point capacity to a maximum of 300 points per panel, or model 5815XL for Hochiki devices to increase the overall point capacity to a maximum of 254 points per panel.

IFP-300 has the interconnection capability for up to 32 panels. The system has two modes of operation, multiple panels covering one larger building, or multiple independent buildings. To network panels together use the SK-NIC network interface card. Copper wire or fiber optic cable panel connectivity can be used within the same networked system.

IFP-300 has a built-in dual phone line, digital alarm communicator/ transmitter (DACT), IP or optional cellular technologies, Form C trouble relay, and two programmable Form C relays. IFP-300 has powerful features such as detector sensitivity, day/night thresholds, drift compensation, pre-trouble maintenance alert, and calibration trouble alert.

The IFP-300 supports a variety of devices, including RA-2000, RA-1000 or RA-100 remote annunciator, 5824 serial/ parallel printer interface module (for printing system reports).

Additional information

Weight 16 lbs
Dimensions 26.40 × 16.40 × 4.10 in
Manufacturer

Honeywell

Brand

,

Condition

New

Type

Control Panel

Style

Addressable

Color

Red

Series

Production Status

Active

Compatibility

IFP-300

Reviews

There are no reviews yet.

Be the first to review “Honeywell IFP-300”

IFP-300 SERIES Intelligent Fire Alarm Control Panel with Communicator

Download

Honeywell - Data Sheet

Device Compatibility Document

Download

Honeywell - Technical Document

IFP-300 / IFP-300ECS Addressable Fire Alarm Control Panel Emergency Communication System

Download

Honeywell - Installation and Operation Guide

Attributes

Weight 16 lbs
Dimensions 26.40 × 16.40 × 4.10 in
Manufacturer

Honeywell

Brand

,

Condition

New

Type

Control Panel

Style

Addressable

Color

Red

Series

Production Status

Active

Compatibility

IFP-300

Product Features

  • Network support for up to 32 Sites
  • Built-in support for up to 159 IDP/SK detectors and 159 IDP/SK modules or 127 SD SLC devices
  • Four line LCD display with 40 characters per line
  • Available in a red or black cabinet
  • IFP-300 can be surface or flush mounted
  • Built-in USB interface for programming
  • Firmware can be upgraded in the field
  • Renewable license on downloading software helps inhibit unauthorized programming
  • Network card allows copper network connection with a multi-mode or single-mode fiber connection option
  • Built-in dual phone line, digital alarm communicator/ transmitter (DACT), IP or optional cellular technologies
  • JumpStart AutoProgramming® feature for easy programming
  • Supports up to four SWIFT wireless gateways. Each gateway can have up to 49 wireless devices
  • Supports Class B (Style 4) and Class A (Style 6 or Style 7 configuration for SLC, and SBUS.
  • Built in synchronization for appliances from AMSECO, Gentex®, System Sensor®, and Wheelock

What's Included

Shipping Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1 – 5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock. PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client.

Return Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee. New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made. See our complete return policy for more information at: https://firealarm.com/faq/

Testimonials

Rick A.
Dallas, TXI
Read More
"Great service. I received help with exactly what I needed and I received it all in a timely manner."
Charles O.
New Brunswick, NJ
Read More
"I had a big engineering/logistics issue that William over at FireAlarm.com helped me with. I don’t know what I would’ve done without their help!"
Jason G.
Los Angeles, CA
Read More
"The fastest delivery I’ve seen. Needed overnight emergency parts and I got just that."
Julia S.
Tampa, FL
Read More
"Needed last-minute maintenance done on my building’s system, and FireAlarm.com exceeded my expectations with how quickly it was done."

Leave a review

Reviews

There are no reviews yet.

Be the first to review “Honeywell IFP-300”

Pricing & Availability Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1 – 5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock. PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client.

Payment Details

You may remit payment via a US-Based Credit Card (CC Authorization Form), Wire Transfer (w/ $30 or $50 fee added to invoice), via PayPal (Or PayPal Pay Later), via Apple or Google Pay, or by mailing us a check. You can also call in with your credit card information at any time: 888-497-0290.

Return & Cancellation Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee. New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made. See our complete return policy for more information at: https://firealarm.com/faq/