Hochiki FNLCDNUS00R024

$1,852.93

Annunciator Network And Backbox (Red)

Availability: Please Call for Availability
Condition: New
Brand: Hochiki
Status: Active
SKU: 71607
Manufacturer Part #: FNLCDNUS00R024

Description

The FN-LCD-N type LCD network annunciator is designed to be used with the FireNET® analog addressable system. It allows for remote access, monitoring, and control of the FireNET® system throughout the building. The FN-LCD-N is a true network annunciator that can access, monitor, and control any or all FireNET® panels in the network. Each FN-LCD-N is completely independent. The highly intuitive user interface and 320-character LCD display of the FN-LCD-N is exactly the same as the FireNET® panel. In addition to routing any panel in the network to the FN-LCD-N, every event category within each panel can also be individually routed, as well as routing of all remote control functions (reset, alarm silence, re-sound alarm) from individual panels. The FN-LCD-N supports the same RS485 expansion port as the FireNET® panel, allowing for FireNET® expansion boards and accessories to be connected to the network annunciator. The FN-LCD-N also has (4) output relays for fire, supervisory, trouble & auxiliary. The relays are programmable (except supervisory). Security is established by the use of a password or firefighters enable key. Designed to be aesthetically pleasing, the FN-LCD-N is available in red or gray and can be surface or flush mounted using a standard trim ring kit.

Documents

Description

The FN-LCD-N type LCD network annunciator is designed to be used with the FireNET® analog addressable system. It allows for remote access, monitoring, and control of the FireNET® system throughout the building. The FN-LCD-N is a true network annunciator that can access, monitor, and control any or all FireNET® panels in the network. Each FN-LCD-N is completely independent. The highly intuitive user interface and 320-character LCD display of the FN-LCD-N is exactly the same as the FireNET® panel. In addition to routing any panel in the network to the FN-LCD-N, every event category within each panel can also be individually routed, as well as routing of all remote control functions (reset, alarm silence, re-sound alarm) from individual panels. The FN-LCD-N supports the same RS485 expansion port as the FireNET® panel, allowing for FireNET® expansion boards and accessories to be connected to the network annunciator. The FN-LCD-N also has (4) output relays for fire, supervisory, trouble & auxiliary. The relays are programmable (except supervisory). Security is established by the use of a password or firefighters enable key. Designed to be aesthetically pleasing, the FN-LCD-N is available in red or gray and can be surface or flush mounted using a standard trim ring kit.

Additional information

Weight 2 lbs
Brand

Condition

New

Production Status

Active

Reviews

There are no reviews yet.

Be the first to review “Hochiki FNLCDNUS00R024”

Attributes

Weight 2 lbs
Brand

Condition

New

Production Status

Active

Product Features

  • UL 864 9th Edition Listed
  • 320 character liquid crystal display (8 line x 40 character)
  • LED indicators for Fire, Supervisory Alarm, Pre-Alarm, Fire Output Active, Power On, On Test, Panel Sounder Silenced, Delay Active, More Events, Point Bypassed, General Trouble, Power Trouble, System Trouble & NAC Trouble
  • Dual RS485 ports for primary fire network
  • RS485 slave bus for expansion – up to 32 FN-4127-IO boards or up to 15 FN-LCD-S serial annunciators and up to 17 FN-4127-IO boards
  • 2 built-in RS-232 interfaces for programming via a PC and serial printer interface
  • 4 on board programmable Form C relays rated at 1 Amp at 30VDC (Fire, Supervisory, Trouble & Auxiliary)
  • Same controls as the FireNET® fire panel (Reset, Panel Sounder Silence, Lamp Test, Alarm Silence, Re-sound Alarm, Fire Drill, Programmable Function, More Events, More Fire Events, Enter & Exit)
  • Local piezo sounder for event notification
  • Supports user codes & firefighter key to enable access & controls
  • Powered by FireNET® Aux 24VDC or UL fire listed Aux. 24VDC supply
  • Available in red or gray, and can be surface or flush mounted (using trim ring)
  • True network annunciator, any or all panels can be routed to the FN-LCD-N. In addition, each event category can be individually routed to the FN-LCD-N
  • Up to (64) FireNET® panels & FN-LCD-N’s can be networked together in any combination
  • 500mA of auxiliary power available rated at 24VDC
  • Auto-learn feature
  • Built-in help & alarm information screens
  • Fire drill function
  • Each FN-LCD-N is completely independent
  • The FN-LCD-N can be configured to remote reset, silence, resound, any or all panels on the network in any combination

What's Included

Shipping Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1 – 5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock. PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client.

Return Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee. New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made. See our complete return policy for more information at: https://firealarm.com/faq/

Testimonials

Rick A.
Dallas, TXI
Read More
"Great service. I received help with exactly what I needed and I received it all in a timely manner."
Charles O.
New Brunswick, NJ
Read More
"I had a big engineering/logistics issue that William over at FireAlarm.com helped me with. I don’t know what I would’ve done without their help!"
Jason G.
Los Angeles, CA
Read More
"The fastest delivery I’ve seen. Needed overnight emergency parts and I got just that."
Julia S.
Tampa, FL
Read More
"Needed last-minute maintenance done on my building’s system, and FireAlarm.com exceeded my expectations with how quickly it was done."

Leave a review

Reviews

There are no reviews yet.

Be the first to review “Hochiki FNLCDNUS00R024”

Pricing & Availability Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1 – 5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock. PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client.

Payment Details

You may remit payment via a US-Based Credit Card (CC Authorization Form), Wire Transfer (w/ $30 or $50 fee added to invoice), via PayPal (Or PayPal Pay Later), via Apple or Google Pay, or by mailing us a check. You can also call in with your credit card information at any time: 888-497-0290.

Return & Cancellation Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee. New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made. See our complete return policy for more information at: https://firealarm.com/faq/