Siemens FC922-UF

Control Panel FA 252-Pt System w/300W PS And Ope

Manufacturer Part #: FC922-UF

Siemens FC922-UF

$1,943.86

Control Panel FA 252-Pt System w/300W PS And Ope

Availability: Please Call for Availability
Condition: New
Brand: Siemens
Status: Active
SKU: 72195
Manufacturer Part #: FC922-UF
Secondary Part #: S54400-C22-A1

Description

The Cerberus PRO 252-point (Model FC922) / 504-point (Model FC924) addressable FACP is designed to meet the fire-protection needs of mid-size buildings. This advanced FACP offers features typically required in mid-size buildings in a package that is easy to install and competitively priced. Additionally, Models FC922 and FC924 are networkable, allowing the systems to fulfill the growing fire-protection needs of the building. The programming software for the 252/ 504-point fire systems is held in flash electrically erasable programmable read-only memory (EEPROM).

Documents

Description

The Cerberus PRO 252-point (Model FC922) / 504-point (Model FC924) addressable FACP is designed to meet the fire-protection needs of mid-size buildings. This advanced FACP offers features typically required in mid-size buildings in a package that is easy to install and competitively priced. Additionally, Models FC922 and FC924 are networkable, allowing the systems to fulfill the growing fire-protection needs of the building. The programming software for the 252/ 504-point fire systems is held in flash electrically erasable programmable read-only memory (EEPROM).

Additional information

Weight 16 lbs
Manufacturer

Siemens Industry, Inc.

Brand

Condition

New

Unit of Measurement

EA (Each)

Type

Control Panel

Style

Addressable

Color

N/A

Series

Production Status

Active

Compatibility

Reviews

There are no reviews yet.

Be the first to review “Siemens FC922-UF”

252-Point and 504-Point Addressable Fire Alarm Control Panel

Download

Siemens – Data Sheet

Attributes

Weight 16 lbs
Manufacturer

Siemens Industry, Inc.

Brand

Condition

New

Unit of Measurement

EA (Each)

Type

Control Panel

Style

Addressable

Color

N/A

Series

Production Status

Active

Compatibility

Product Features

  • Addressable fire alarm control panel (FACP) intended for mid-size building applications
  • Comprised of the following system components:
    • Operating units
    • Periphery boards
    • Power supplies
    • System enclosures ‘Walk Test’
  • System features: Supports 252-to-504 addressable devices:
    • One (1) to four (4) ‘Class B’; one (1) to two (2) ‘Class A’ for Model FC922
    • One (1) to eight (8) ‘Class B’; one (1) to four (4) ‘Class A’ for Model FC924
  • 10,000-event history-logging capability
  • Includes one (1) ‘Class A’ or two (2) ‘Class B’ notification appliance circuits (NACs)
  • Resettable and non-resettable 24VDC, [nominal] auxiliary power
  • Connectivity to a leased-line / city-tie module
  • Releasing module supports activation of releasing valves in pre-action / deluge systems / agent release
  • Off-normal warning message prior to reset
  • Fast and easy set-up with auto-configuration feature
  • Networkable up to 32 panels using CV Web or up to 16 panels using SafeDLink
  • Cerberus® DMS Danger Management Station can monitor and control up to 32 Models FC922 and FC924 FACPs
  • Supports multiple global displays
  • Digital alarm communication transmitter (DACT)
  • UL 864 10th Edition Listed, ULC-S527 Listed
  • FM, CSFM & NYC Fire Department Approved

What's Included

Shipping Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1 – 5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock. PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client.

Return Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee. New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made. See our complete return policy for more information at: https://firealarm.com/faq/

Testimonials

Rick A.
Dallas, TXI
Read More
"Great service. I received help with exactly what I needed and I received it all in a timely manner."
Charles O.
New Brunswick, NJ
Read More
"I had a big engineering/logistics issue that William over at FireAlarm.com helped me with. I don’t know what I would’ve done without their help!"
Jason G.
Los Angeles, CA
Read More
"The fastest delivery I’ve seen. Needed overnight emergency parts and I got just that."
Julia S.
Tampa, FL
Read More
"Needed last-minute maintenance done on my building’s system, and FireAlarm.com exceeded my expectations with how quickly it was done."

Leave a review

Reviews

There are no reviews yet.

Be the first to review “Siemens FC922-UF”

You may also like...

Pricing & Availability Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1 – 5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock. PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client.

Payment Details

You may remit payment via a US-Based Credit Card (CC Authorization Form), Wire Transfer (w/ $30 or $50 fee added to invoice), via PayPal (Or PayPal Pay Later), via Apple or Google Pay, or by mailing us a check. You can also call in with your credit card information at any time: 888-497-0290.

Return & Cancellation Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee. New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made. See our complete return policy for more information at: https://firealarm.com/faq/