Simplex 49VOC-CWS

$7.21

Visual Only, Ceiling Mount. White Logo Only

Availability: In Stock
Condition: New
Brand: Simplex
Status: Active
SKU: 72611
Manufacturer Part #: 49VOC-CWS

Description

Ceiling mount addressable visible (V/O) notification appliances are individually powered, addressed, and controlled from a Simplex fire alarm control unit (FACU) IDNAC Signaling Line Circuit (SLC). V/O notification appliances use a multi-candela strobe with synchronized 1 Hz flash rate and selectable candela rating. Xenon tube strobes devices are interoperable on the same IDNAC channel. Separate appliance and cover selection greatly simplifies the ordering and installation process.

Documents

Description

Ceiling mount addressable visible (V/O) notification appliances are individually powered, addressed, and controlled from a Simplex fire alarm control unit (FACU) IDNAC Signaling Line Circuit (SLC). V/O notification appliances use a multi-candela strobe with synchronized 1 Hz flash rate and selectable candela rating. Xenon tube strobes devices are interoperable on the same IDNAC channel. Separate appliance and cover selection greatly simplifies the ordering and installation process.

Additional information

Weight 0.4 lbs
Brand

Condition

New

Production Status

Active

Reviews

There are no reviews yet.

Be the first to review “Simplex 49VOC-CWS”

Attributes

Weight 0.4 lbs
Brand

Condition

New

Production Status

Active

Product Features

  • Multi-candela Xenon strobe available in low: 15 cd, 30 cd, 75 cd, and 110 cd; and high: 110 cd, 135 cd, and 185 cd range candela models
  • Small compact design and low current draw due to energy efficient Xenon tube strobes, with LED indicators
  • Advanced addressable notification controlled by IDNAC SLCs.
  • IDNAC SLCs provide regulated 29 VDC allowing horns to operate with lower current
  • Electrical test point access by removing the cover
  • Strobe intensity can be programmed from the FACU or the device
  • Wiring supervision to each appliance allows T-tapped connections for Class B circuits to simplify wiring. Class A circuits require in/out wiring
  • Self-Test Mode allows on-board sensors to detect the strobe output and then report their status to the FACU
  • TrueAlert Device Reports at the FACU detail appliance point ID, custom label, type, and candela setting
  • Magnet test diagnostics assist checkout and testing of appliances and wiring
  • Compatibility with ADA requirements
  • Strobe operation is listed to UL Standard 1971 and ULC Standard S526
  • Synchronized strobe operation on its IDNAC channel

What's Included

Shipping Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1 – 5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock. PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client.

Return Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee. New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made. See our complete return policy for more information at: https://firealarm.com/faq/

Testimonials

Rick A.
Dallas, TXI
Read More
"Great service. I received help with exactly what I needed and I received it all in a timely manner."
Charles O.
New Brunswick, NJ
Read More
"I had a big engineering/logistics issue that William over at FireAlarm.com helped me with. I don’t know what I would’ve done without their help!"
Jason G.
Los Angeles, CA
Read More
"The fastest delivery I’ve seen. Needed overnight emergency parts and I got just that."
Julia S.
Tampa, FL
Read More
"Needed last-minute maintenance done on my building’s system, and FireAlarm.com exceeded my expectations with how quickly it was done."

Leave a review

Reviews

There are no reviews yet.

Be the first to review “Simplex 49VOC-CWS”

Pricing & Availability Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1 – 5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock. PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client.

Payment Details

You may remit payment via a US-Based Credit Card (CC Authorization Form), Wire Transfer (w/ $30 or $50 fee added to invoice), via PayPal (Or PayPal Pay Later), via Apple or Google Pay, or by mailing us a check. You can also call in with your credit card information at any time: 888-497-0290.

Return & Cancellation Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee. New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made. See our complete return policy for more information at: https://firealarm.com/faq/