Altronix AL400ACMCB220

$343.81

Access Power Controller w/ Power Supply/Charger, 8 PTC Class 2 Relay Outputs, 12/24VDC @ 4A, FAI, 220VAC, BC400 Enclosure

Availability: Estimated 1 - 3 Weeks

  • Factory New
Brand: Altronix FireAlarm.com Part #: 155039 Category: Manufacturer Part #: AL400ACMCB220 Tags: ,

Description

AL400ACMCB220 converts a nominal 220VAC 50/60Hz input into eight (8) independently controlled 12VDC or 24VDC Fail-Safe and/or Fail-Secure outputs with a total of 4A @ 12VDC or 3A @ 24VDC continuous supply current. Outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc. This unit will route power to a variety of access control hardware devices including Mag Locks, Electric Strikes, Magnetic Door Holders, etc. The outputs will operate in both Fail-Safe and/or Fail-Secure modes. This unit is designed to be powered by one common power source (factory installed) which will provide power for both the board operation and locking devices, or two (2) totally independent power sources, one (1) providing power for board operation and the other for lock / accessory power. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the eight (8) outputs.

Information

Weight 12.00 lbs
Dimensions 4.5 × 12.00 × 15.50 in
Manufacturer

Altronix Corp.

Brand

Altronix

Condition

New

Unit of Measurement

EA (Each)

Production Status

Active

Features

  • Eight (8) independently controlled Fail-Safe and/or Fail-Secure power outputs
  • Eight (8) auxiliary power outputs (unswitched)
  • Output PTCs are rated @ 2.5A
  • Filtered and electronically regulated outputs
  • Supervision: AC Fail, Battery Fail and Battery Presence
  • Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the eight (8) outputs
  • Alarm output relay indicates that FACP input is triggered
  • Fire Alarm disconnect input options: a) Normally open (NO) or normally closed (NC) dry contact input, b) Polarity reversal input from FACP signaling circuit
  • Built-in charger for sealed lead acid or gel type batteries
  • Instantaneous transfer to stand-by batteries
  • CE European Conformity
  • Lifetime Warranty

Power Supply/Chargers with Multi-Output Access Power Controllers; ACMCB220 Series

Altronix - Data Sheet

Access Power Controllers with Power Supplies; ACMCB220 Series

Altronix - Installation Manual