Apollo SA4705-600APO Soteria UL Mini Monitor Module

SKU: 70294
Manufacturer Part #: SA4705-600APO
Condition: New
Brand: Apollo
Status: Active
Note: This is a direct replacement for the 55000-831, 55000-830.

Loop Powered Mini Monitor, IDC Input

$90.99

Estimated 10 business days
On Backorder
Join FireAlarm Plus to reduce your cost per unit and gain faster access to inventory on this purchase.

Description

The Apollo SA4705-600APO Soteria UL Mini Switch Monitor Module is a loop-powered intelligent monitor module designed to interface with normally-open dry contact devices. It incorporates a supervised initiating device circuit (IDC) and communicates using XP95 and Discovery digital communication protocols.

The module is supplied as a compact PCB assembly enclosed in a two-part UL94 V-0 polycarbonate housing with seven 150 mm flying leads for connection. A built-in isolator enhances loop integrity, while selectable wiring (Class A or Class B) and priority settings allow flexible installation configurations.

Designed for indoor dry environments, the SA4705-600APO supports ground fault detection (configurable via DIP switch) and provides visual LED status indication for polling, isolation, and alarm conditions.

Documents

Description

The Apollo SA4705-600APO Soteria UL Mini Switch Monitor Module is a loop-powered intelligent monitor module designed to interface with normally-open dry contact devices. It incorporates a supervised initiating device circuit (IDC) and communicates using XP95 and Discovery digital communication protocols.

The module is supplied as a compact PCB assembly enclosed in a two-part UL94 V-0 polycarbonate housing with seven 150 mm flying leads for connection. A built-in isolator enhances loop integrity, while selectable wiring (Class A or Class B) and priority settings allow flexible installation configurations.

Designed for indoor dry environments, the SA4705-600APO supports ground fault detection (configurable via DIP switch) and provides visual LED status indication for polling, isolation, and alarm conditions.

Additional information

Weight 0.2 lbs
Dimensions 1.9 × 3.0 × 0.6 in
Manufacturer

Apollo Fire Detectors

Brand

Apollo

Condition

New

Unit of Measurement

EA (Each)

Production Status

Active

Type

Module

Series

Protocol

Discovery, XP95

Voltage Range

17–28 VDC

Voltage

3.3 VDC

EOL Resistance

47 kΩ

Location

Indoor

Material

Polycarbonate

Listings & Approvals

CSFM, FM, UL, ULC

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

Attributes

Additional information

Weight 0.2 lbs
Dimensions 1.9 × 3.0 × 0.6 in
Manufacturer

Apollo Fire Detectors

Brand

Apollo

Condition

New

Unit of Measurement

EA (Each)

Production Status

Active

Type

Module

Series

Protocol

Discovery, XP95

Voltage Range

17–28 VDC

Voltage

3.3 VDC

EOL Resistance

47 kΩ

Location

Indoor

Material

Polycarbonate

Listings & Approvals

CSFM, FM, UL, ULC

Product Features

  • Loop-powered mini switch monitor module
  • Digital communication compatible with XP95 and Discovery protocols
  • Built-in short-circuit isolator
  • Supervised initiating device circuit (Class A or Class B selectable)
  • Selectable priority function (DIP switch configurable)
  • Ground fault detection (DIP switch enabled)
  • Visible LED status indicators (Green, Yellow, Red)
  • Compact form factor for limited space applications
  • Indoor dry use only
  • All circuits power-limited

What's Included

Shipping Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1–5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock.

PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client. This product may be sourced from the manufacturer or supplier. If so, manufacturer cancellation fees may apply if the order is cancelled after processing. See our Terms of Sale for details.

Return Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee.

New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made.

Testimonials

Rick A.
Dallas, TXI
"Great service. I received help with exactly what I needed and I received it all in a timely manner."
Charles O.
New Brunswick, NJ
"I had a big engineering/logistics issue that William over at FireAlarm.com helped me with. I don’t know what I would’ve done without their help!"
Jason G.
Los Angeles, CA
"The fastest delivery I’ve seen. Needed overnight emergency parts and I got just that."
Julia S.
Tampa, FL
"Needed last-minute maintenance done on my building’s system, and FireAlarm.com exceeded my expectations with how quickly it was done."

Leave a review

Pricing & Availability Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1 – 5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock. PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client.

Payment Details

You may remit payment via a US-Based Credit Card (CC Authorization Form), Wire Transfer (w/ $30 or $50 fee added to invoice), via PayPal (Or PayPal Pay Later), via Apple or Google Pay, or by mailing us a check. You can also call in with your credit card information at any time: 888-497-0290.

Return & Cancellation Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee. New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made. See our complete return policy for more information at: https://firealarm.com/faq/