Det-Tronics CGSS1C3C2R1X (006824-007)

$1,056.77

Combustible Gas Sensor for UD10, UD30, CTX10, DCUEX, U9500A, U8700, 400, 405, 810, 820, and 880 Transmitters

Availability: Estimated 56 days
Condition: New
Brand: Det-Tronics
Status: Active
SKU: 132396
Manufacturer Part #: CGSS1C3C2R1X
Secondary Part #: 006824-007

Description

CGS Combustible Gas Sensor. Stainless steel catalytic sensor that provides an accurate measurement of combustible gas concentration in the % LFL range. Requires FlexVu UD10, Model 505, U9500A or FlexVu UD30 transmitter.

Documents

Description

CGS Combustible Gas Sensor. Stainless steel catalytic sensor that provides an accurate measurement of combustible gas concentration in the % LFL range. Requires FlexVu UD10, Model 505, U9500A or FlexVu UD30 transmitter.

Additional information

Weight 0.2 lbs
Manufacturer

Carrier

Brand

Condition

New

Unit of Measurement

EA (Each)

Production Status

Active

Model

CGS

Catalytic Combustible Gas Sensor; Model CGS

Download

Det-Tronics - Data Sheet

2023 Det-Tronics Product Catalog

Download

Det-Tronics – Product Catalog

Attributes

Weight 0.2 lbs
Manufacturer

Carrier

Brand

Condition

New

Unit of Measurement

EA (Each)

Production Status

Active

Model

CGS

Product Features

  • Compliance to ANSI/ISA-12.13.01-2000 performance standard
  • Performance certified to FM 6310/6320, CSA 22.2 #154, and ATEX EN60079-29-1
  • Performance certified to IEC60079-29-1 when connected to the FlexVu UD10, UD10-DCU
  • Detects hydrogen and hydrocarbon gases
  • Constant current or constant voltage options available
  • Poison resistant construction
  • 3/4” NPT or 20 mm thread option
  • Wire lead options of 6” or 30”
  • Sensor Separation Termination Box (STB) option available
  • Variety of special accessories available
  • FlexVu UD10 universal display provides full digital readout, calibration and user interface
  • Performance approved from –40°C to 75°C for life safety applications
  • Hazardous Location approved from –55°C to 125°C for process control applications
  • SIL2 certified when used with FlexVu UD10 and UD30 Universal Displays

What's Included

Shipping Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1 – 5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock. PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client.

Return Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee. New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made. See our complete return policy for more information at: https://firealarm.com/faq/

Testimonials

Rick A.
Dallas, TXI
Read More
"Great service. I received help with exactly what I needed and I received it all in a timely manner."
Charles O.
New Brunswick, NJ
Read More
"I had a big engineering/logistics issue that William over at FireAlarm.com helped me with. I don’t know what I would’ve done without their help!"
Jason G.
Los Angeles, CA
Read More
"The fastest delivery I’ve seen. Needed overnight emergency parts and I got just that."
Julia S.
Tampa, FL
Read More
"Needed last-minute maintenance done on my building’s system, and FireAlarm.com exceeded my expectations with how quickly it was done."

Leave a review

Pricing & Availability Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1 – 5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock. PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client.

Payment Details

You may remit payment via a US-Based Credit Card (CC Authorization Form), Wire Transfer (w/ $30 or $50 fee added to invoice), via PayPal (Or PayPal Pay Later), via Apple or Google Pay, or by mailing us a check. You can also call in with your credit card information at any time: 888-497-0290.

Return & Cancellation Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee. New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made. See our complete return policy for more information at: https://firealarm.com/faq/