This product has been replaced by

Det-Tronics X2200A4M23T2 (008443-001)

X2200 UV Flame Detector; Aluminum, 4 Port, M25, HART, Relay, and 0-20 mA, SIL/FM/CSA/ATEX/IECEx, Division/Zone Ex d

Manufacturer Part #: X2200A4M23T2

Det-Tronics X2200A4M23T2 (008443-001)

X2200 UV Flame Detector; Aluminum, 4 Port, M25, HART, Relay, and 0-20 mA, SIL/FM/CSA/ATEX/IECEx, Division/Zone Ex d

Availability: Please Call for Availability
Condition: New
Brand: Det-Tronics
Status: Active
SKU: 133280
Manufacturer Part #: X2200A4M23T2
Secondary Part #: 008443-001

Description

The X2200 UV Flame Detector meets the most stringent requirements worldwide with advanced detection capabilities and immunity to extraneous sources, combined with a superior mechanical design. The detector is equipped with both automatic and manual oi test capability. The detector has Division and Zone explosion-proof ratings and is suitable for use in indoor and outdoor applications. The standard output configuration includes fire, fault and auxiliary relays. An optional 0 to 20 mA output with HART can be provided in addition to the three relays. A model with pulse output is available for easy retrofitting into existing Det-Tronics controller-based systems. Auxiliary relay and 0 to 20 mA output are not available with the pulse model. A tri-color LED on the detector faceplate indicates normal condition and notifies personnel of fire alarm or fault conditions.

Documents

Description

The X2200 UV Flame Detector meets the most stringent requirements worldwide with advanced detection capabilities and immunity to extraneous sources, combined with a superior mechanical design. The detector is equipped with both automatic and manual oi test capability. The detector has Division and Zone explosion-proof ratings and is suitable for use in indoor and outdoor applications. The standard output configuration includes fire, fault and auxiliary relays. An optional 0 to 20 mA output with HART can be provided in addition to the three relays. A model with pulse output is available for easy retrofitting into existing Det-Tronics controller-based systems. Auxiliary relay and 0 to 20 mA output are not available with the pulse model. A tri-color LED on the detector faceplate indicates normal condition and notifies personnel of fire alarm or fault conditions.

Additional information

Weight 7 lbs
Manufacturer

Carrier

Brand

Condition

New

Unit of Measurement

EA (Each)

Production Status

Active

Model

X2200

Type

Flame Detector

Material

Aluminum

Thread Type

4 Port

Thread Size

M25

Output

0-20 mA, HART, Relay

Listings & Approvals

ATEX, CSA, FM, IECEx, SIL

Classification

Division/Zone Ex d

UV Flame Detector; X2200/X2200G/X2200M

Download

Det-Tronics - Data Sheet

2023 Det-Tronics Product Catalog

Download

Det-Tronics - Product Catalog

Attributes

Weight 7 lbs
Manufacturer

Carrier

Brand

Condition

New

Unit of Measurement

EA (Each)

Production Status

Active

Model

X2200

Type

Flame Detector

Material

Aluminum

Thread Type

4 Port

Thread Size

M25

Output

0-20 mA, HART, Relay

Listings & Approvals

ATEX, CSA, FM, IECEx, SIL

Classification

Division/Zone Ex d

Product Features

  • Models available with SIL 2 certification
  • ARC rejection – Advanced signal processing
  • Unequaled false alarm rejection – Solar blind
  • Responds to a fire in the presence of modulated blackbody radiation without false alarm
  • Ultra-High speed capability
  • Optional HART output and AMS aware
  • Automatic, manual, or magnetic oi (optical integrity) testing
  • Pulse output for compatibility with Det-Tronics R74XX controller-based systems (optional)
  • FM, CSA, ATEX, CE, and IECEx
  • EN 54 part 10 certified by BRE, LPCB
  • Tricolor LED indicates normal operation, fire, and fault conditions
  • Mounting arm allows easy sighting
  • Integral wiring compartment for ease of installation
  • Terminal block allows for Class X Pathway Designation per NFPA 72
  • EMI, RFI, EMC Directive Compliant
  • Built-in data logging / event monitoring
  • Molybdenum Model available for applications that require increased spectral sensitivity

What's Included

Shipping Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1 – 5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock. PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client.

Return Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee. New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made. See our complete return policy for more information at: https://firealarm.com/faq/

Testimonials

Rick A.
Dallas, TXI
Read More
"Great service. I received help with exactly what I needed and I received it all in a timely manner."
Charles O.
New Brunswick, NJ
Read More
"I had a big engineering/logistics issue that William over at FireAlarm.com helped me with. I don’t know what I would’ve done without their help!"
Jason G.
Los Angeles, CA
Read More
"The fastest delivery I’ve seen. Needed overnight emergency parts and I got just that."
Julia S.
Tampa, FL
Read More
"Needed last-minute maintenance done on my building’s system, and FireAlarm.com exceeded my expectations with how quickly it was done."

Leave a review

You may also like...

Pricing & Availability Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1 – 5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock. PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client.

Payment Details

You may remit payment via a US-Based Credit Card (CC Authorization Form), Wire Transfer (w/ $30 or $50 fee added to invoice), via PayPal (Or PayPal Pay Later), via Apple or Google Pay, or by mailing us a check. You can also call in with your credit card information at any time: 888-497-0290.

Return & Cancellation Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee. New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made. See our complete return policy for more information at: https://firealarm.com/faq/