The Modem Communicator is a two-way local rail module that performs a variety of off-premise communications functions for the system. Using the latest in digital signal processing (DSP) techniques, the Modcom provides off premise communication features unavailable on any other system. The module has provisions for supervising two loop-start telephone lines. The module features a modular jack for telephone line connections. The Modcom’s configuration and firmware can also be updated from any network node. Modcom series modules occupy a single local rail space and can be mounted in any panel on the network. Most system Control/ Display modules can be mounted in front of the Modcom series module. Power for the Modcom is supplied by the system power supply. The Modcom provides an enhanced level of survivability in the event of a network CPU failure by notifying the Central Monitoring Station of the failure and entering a degraded mode of operation. In degraded mode, the Modcom can transmit a default fire alarm message during a fire alarm condition.

Documents

Description

The Modem Communicator is a two-way local rail module that performs a variety of off-premise communications functions for the system.

Using the latest in digital signal processing (DSP) techniques, the Modcom provides off premise communication features unavailable on any other system.

The module has provisions for supervising two loop-start telephone lines. The module features a modular jack for telephone line connections. The Modcom’s configuration and firmware can also be updated from any network node.

Modcom series modules occupy a single local rail space and can be mounted in any panel on the network. Most system Control/ Display modules can be mounted in front of the Modcom series module. Power for the Modcom is supplied by the system power supply.

The Modcom provides an enhanced level of survivability in the event of a network CPU failure by notifying the Central Monitoring Station of the failure and entering a degraded mode of operation. In degraded mode, the Modcom can transmit a default fire alarm message during a fire alarm condition.

Additional information

Weight 0.5 lbs
Dimensions 10.5 × 2.3 × 1.8 in
Series

Condition

New

Brand

,

Production Status

Active

Reviews

There are no reviews yet.

Be the first to review “Edwards EST 3-MODCOMP”

Modem Communicator: 3-MODCOM, 3-MODCOMP

Download

Edwards - Data Sheet

Attributes

Weight 0.5 lbs
Dimensions 10.5 × 2.3 × 1.8 in
Series

Condition

New

Brand

,

Production Status

Active

Product Features

  • Listed for fire and security
  • V.32bis 14.4K full duplex modem
  • Digital alarm communicator transmitter supporting: DIA DCS protocol, Contact ID protocol, 3/1 and 4/2 pulse format protocol
  • Supports “tap” alphanumeric pager protocol
  • Fully programmable messages
  • Alarm override of upload/download
  • Two phone line capability
  • Field upgradable firmware
  • Split and multiple reporting to as many as 80 different receivers
  • 255 subscriber accounts
  • Supports control/display modules
  • Supervised by the network controller
  • Supports Cellular communications

What's Included

Shipping Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1 – 5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock. PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client.

Return Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee. New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made. See our complete return policy for more information at: https://firealarm.com/faq/

Testimonials

Rick A.
Dallas, TXI
Read More
"Great service. I received help with exactly what I needed and I received it all in a timely manner."
Charles O.
New Brunswick, NJ
Read More
"I had a big engineering/logistics issue that William over at FireAlarm.com helped me with. I don’t know what I would’ve done without their help!"
Jason G.
Los Angeles, CA
Read More
"The fastest delivery I’ve seen. Needed overnight emergency parts and I got just that."
Julia S.
Tampa, FL
Read More
"Needed last-minute maintenance done on my building’s system, and FireAlarm.com exceeded my expectations with how quickly it was done."

Leave a review

Reviews

There are no reviews yet.

Be the first to review “Edwards EST 3-MODCOMP”

Pricing & Availability Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1 – 5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock. PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client.

Payment Details

You may remit payment via a US-Based Credit Card (CC Authorization Form), Wire Transfer (w/ $30 or $50 fee added to invoice), via PayPal (Or PayPal Pay Later), via Apple or Google Pay, or by mailing us a check. You can also call in with your credit card information at any time: 888-497-0290.

Return & Cancellation Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee. New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made. See our complete return policy for more information at: https://firealarm.com/faq/