Edwards EST SIGA-CC1S Synchronization Output Module

SKU: 28339
Manufacturer Part #: SIGA-CC1S
Condition: New
Brand: Edwards, EST
Status: Active

Synchronization Output Module, Class B Output

$92.49

Ships in 8 business days
In Stock
Join FireAlarm Plus to reduce your cost per unit and gain faster access to inventory on this purchase.

Description

This intelligent addressable output module provides UL 1971-compliant synchronization for visual notification appliances across multiple zones on Edwards Signature loop systems. It is part of the Signature Series and its operation is determined by a downloadable personality code: Code 25 for visual signal synchronization, Code 5 for signal power or audio evacuation riser selection, or Code 6 for telephone circuits with a built-in ring-tone generator.

The SIGA-CC1S connects a supervised Class B output circuit to a supervised 24 VDC riser input for audible/visible signals, or to 25 and 70 VRMS inputs for audio evacuation speakers and firefighter telephones. It monitors the output wiring for open and short circuits, a short causes the panel to inhibit activation to prevent connection to the fault. Addresses are electronically programmed from the loop controller or the SIGA-PRO service tool; no switches or dials are required.

The module mounts to a standard North American 2-gang box (2½" deep) or a 4" square box (1½" deep) with 2-gang cover and SIGA-MP mounting plate. It is compatible with EST3, EST3X, and iO Series control panels under Signature Loop Controller version 2.0 or higher.

Documents

Description

This intelligent addressable output module provides UL 1971-compliant synchronization for visual notification appliances across multiple zones on Edwards Signature loop systems. It is part of the Signature Series and its operation is determined by a downloadable personality code: Code 25 for visual signal synchronization, Code 5 for signal power or audio evacuation riser selection, or Code 6 for telephone circuits with a built-in ring-tone generator.

The SIGA-CC1S connects a supervised Class B output circuit to a supervised 24 VDC riser input for audible/visible signals, or to 25 and 70 VRMS inputs for audio evacuation speakers and firefighter telephones. It monitors the output wiring for open and short circuits, a short causes the panel to inhibit activation to prevent connection to the fault. Addresses are electronically programmed from the loop controller or the SIGA-PRO service tool; no switches or dials are required.

The module mounts to a standard North American 2-gang box (2½” deep) or a 4″ square box (1½” deep) with 2-gang cover and SIGA-MP mounting plate. It is compatible with EST3, EST3X, and iO Series control panels under Signature Loop Controller version 2.0 or higher.

Additional information

Weight 0.5 lbs
Manufacturer

Carrier

Brand

Edwards, EST

Condition

New

Unit of Measurement

EA (Each)

Production Status

Active

Type

Addressable Control Module, Intelligent Module

Style

Synchronization

Color

White

Mounting

2-Gang, 4" Square, SIGA-MP

Programming

Electronic

Protocol

Signature Loop Controller

Voltage

19 VDC

Voltage Range

15.20 – 19.95 VDC

EOL Resistance

47K Ohms

Series

Compatibility

, , ,

Listings & Approvals

CSFM, MEA, UL, ULC

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

Attributes

Additional information

Weight 0.5 lbs
Manufacturer

Carrier

Brand

Edwards, EST

Condition

New

Unit of Measurement

EA (Each)

Production Status

Active

Type

Addressable Control Module, Intelligent Module

Style

Synchronization

Color

White

Mounting

2-Gang, 4" Square, SIGA-MP

Programming

Electronic

Protocol

Signature Loop Controller

Voltage

19 VDC

Voltage Range

15.20 – 19.95 VDC

EOL Resistance

47K Ohms

Series

Compatibility

, , ,

Listings & Approvals

CSFM, MEA, UL, ULC

Product Features

  • UL 1971-compliant auto-sync output for Edwards Enhanced Integrity and Genesis visual signals
  • Three selectable personality codes: sync (Code 25), signal/audio riser (Code 5), telephone with ring-tone (Code 6)
  • Built-in ring-tone generator eliminates separate ring-tone circuit for telephone applications
  • Electronic addressing — no switches or dials; programmed via loop controller or SIGA-PRO tool
  • On-board microprocessor handles all decisions locally, reducing loop sensitivity to noise
  • Automatic device mapping reports circuit location to the loop controller
  • Monitors output wiring for open and short circuits; inhibits activation on short
  • Green LED flashes when polled; red LED flashes when active/alarm
  • Twisted or shielded wire not required
  • Compatible with EST3, EST3X, and iO Series panels

What's Included

Shipping Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1–5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock.

PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client. This product may be sourced from the manufacturer or supplier. If so, manufacturer cancellation fees may apply if the order is cancelled after processing. See our Terms of Sale for details.

Return Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee.

New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made.

Testimonials

Rick A.
Dallas, TXI
"Great service. I received help with exactly what I needed and I received it all in a timely manner."
Charles O.
New Brunswick, NJ
"I had a big engineering/logistics issue that William over at FireAlarm.com helped me with. I don’t know what I would’ve done without their help!"
Jason G.
Los Angeles, CA
"The fastest delivery I’ve seen. Needed overnight emergency parts and I got just that."
Julia S.
Tampa, FL
"Needed last-minute maintenance done on my building’s system, and FireAlarm.com exceeded my expectations with how quickly it was done."

Leave a review

Edwards Signaling 27193-21 Surface Mount Box, Red, 2-Gang
Mfr. Part #: 27193-21
SKU: 5101
Limited Stock
Ships in 5 business days

$30.49

Edwards EST SIGA-MCC1S
Mfr. Part #: SIGA-MCC1S
SKU: 38092
On Backorder
Estimated 25 business days

$197.49

Pricing & Availability Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1 – 5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock. PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client.

Payment Details

You may remit payment via a US-Based Credit Card (CC Authorization Form), Wire Transfer (w/ $30 or $50 fee added to invoice), via PayPal (Or PayPal Pay Later), via Apple or Google Pay, or by mailing us a check. You can also call in with your credit card information at any time: 888-497-0290.

Return & Cancellation Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee. New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made. See our complete return policy for more information at: https://firealarm.com/faq/