Edwards Signaling E-PD

Intelligent Analog Optical Smoke Detector

Availability: Please call for availability
Condition: New
Brand: Edwards Signaling
Status: Discontinued
SKU: 5810
Manufacturer Part #: E-PD
Replacement: KIR-PD

Description

This intelligent analog device uses an optical sensing chamber to detect smoke. The detector analyzes sensitivity reference values gathered by the sensor to determine when an alarm is initiated. The E-PD is capable of performing comprehensive self-diagnostics and storing the data. The detector continuously adjusts its sensitivity reference value based on fluctuating environmental conditions such as the presence of dirt, humidity, or changes in temperature. When the detector approaches its preset sensitivity reference value threshold, it issues a dirty sensor warning, allowing enough of a margin for maintenance personnel to replace the optical chamber before it goes into trouble condition. Thanks to its high-performance optical sensing chamber, the E-PD responds quickly and reliably to a wide range of fire types, especially slow burning fires fueled by combustibles typically found in modern multi-use buildings. The E-PD detects extremely small particles and triggers an alarm at the first sign of smoke.

Documents

Description

This intelligent analog device uses an optical sensing chamber to detect smoke. The detector analyzes sensitivity reference values gathered by the sensor to determine when an alarm is initiated. The E-PD is capable of performing comprehensive self-diagnostics and storing the data.

The detector continuously adjusts its sensitivity reference value based on fluctuating environmental conditions such as the presence of dirt, humidity, or changes in temperature. When the detector approaches its preset sensitivity reference value threshold, it issues a dirty sensor warning, allowing enough of a margin for maintenance personnel to replace the optical chamber before it goes into trouble condition.

Thanks to its high-performance optical sensing chamber, the E-PD responds quickly and reliably to a wide range of fire types, especially slow burning fires fueled by combustibles typically found in modern multi-use buildings. The E-PD detects extremely small particles and triggers an alarm at the first sign of smoke.

Additional information

Weight 0.25 lbs
Programming

Rotary Dials

Detection Method

Photoelectric

Series

Production Status

Discontinued

Brand

Reviews

There are no reviews yet.

Be the first to review “Edwards Signaling E-PD”

Application Bulletin: Smoke, Heat, and Duct Detectors

Download

Edwards Signaling - Application Bulletin

Intelligent/Addressable Detectors & Bases

Download

Edwards Signaling - Data Sheet

E-PD Photoelectric Smoke Detector

Download

Edwards Signaling - Installation Sheet

Attributes

Weight 0.25 lbs
Programming

Rotary Dials

Detection Method

Photoelectric

Series

Production Status

Discontinued

Brand

Product Features

  • Optical smoke, heat, and multi sensor models available
  • Field replaceable optical chamber
  • Highly stable design
  • Compatible standard, relay, isolator, and audible bases
  • Head and terminal base tamper resistant design for fast installation and security
  • Self diagnostic capability with on-board storage of data
  • Optical detectors feature automatic rate compensated sensitivity adjustment, as well as dirty sensor warnings
  • Manufactured to strict international ISO 9001 standards
  • Low profile aesthetically pleasing design

What's Included

Shipping Details

Lead times are based on details provided by our suppliers. This is the best information we have currently. Product availability and pricing may change depending on market conditions. All orders are subject to processing time at our main shipment hub. Additionally, orders cannot be expedited unless they are currently in stock.

Return Details

This item must be returned within 45 days of the date it was purchased, shipped, delivered, or made ready for pickup. Refunds and returns must be sent via email to [email protected]. Please outline the items being returned, the reason for the return, along with any pictures of additional information about the product. See the return policy for complete information.

Testimonials

Rick A.
Dallas, TXI
Read More
"Great service. I received help with exactly what I needed and I received it all in a timely manner."
Charles O.
New Brunswick, NJ
Read More
"I had a big engineering/logistics issue that William over at FireAlarm.com helped me with. I don’t know what I would’ve done without their help!"
Jason G.
Los Angeles, CA
Read More
"The fastest delivery I’ve seen. Needed overnight emergency parts and I got just that."
Julia S.
Tampa, FL
Read More
"Needed last-minute maintenance done on my building’s system, and FireAlarm.com exceeded my expectations with how quickly it was done."

Leave a review

Reviews

There are no reviews yet.

Be the first to review “Edwards Signaling E-PD”

Pricing & Availability Details

Lead times are based on details provided by our suppliers. This is the best information we have currently. Product availability and pricing may change depending on market conditions. All orders are subject to processing time at our main shipment hub. Additionally, orders cannot be expedited unless they are currently in stock.

Payment Details

We accept payments by Credit card, PayPal, Wire Transfer, and mail in checks. All orders are subject to processing time at our main shipment hub.  After placing your order, you will be sent your shipment tracking number after the mandatory processing has been completed.

Return & Cancellation Details

This item must be returned within 45 days of the date it was purchased, shipped, delivered, or made ready for pickup. Refunds and returns must be sent via email to [email protected]. Please outline the items being returned, the reason for the return, along with any pictures of additional information about the product. See the return policy for complete information.