The SHP‐Pro is a microprocessor based, compact, cost‐ effective, conventional fire alarm and fire suppression releasing control panel. The panel is easily configured using configuration dip‐switches provided on the SHP‐Pro main board to operate in any of the following operating modes.

Additional information

Weight 16 lbs
Manufacturer

Fike Corporation

Brand

Condition

New

Unit of Measurement

EA (Each)

Production Status

Active

Features

  • Ten system status LEDs (AC Normal, Alarm, PreDischarge, Release, Supervisory, Trouble, Panel Silenced, Abort, Release Disabled, Ground Fault)
  • General Alarm, Supervisory and Trouble relays
  • Dip‐switch panel configuration
  • Seven segment system status and diagnostic LED
  • Local sounder (piezo) with distinct event tones
  • Reset and Silence switches
  • Disable switch for audible, releasing and relays (hardware disconnect)
  • Alarm and Trouble silence resound (after 18 hrs.)
  • Five selectable abort types
  • Gentex or System Sensor sync protocol
  • Twenty event history buffer
  • Audibles selectable for slow, fast, continuous operation
  • Integral 24 VDC power supply, 1A standby/4A alarm
  • 120/240 VAC at 50/60 Hz power input
  • Resettable and non‐resettable 24 VDC power output
  • Battery and ground fault supervision
  • 7 – 40 AH battery charging capacity
  • Carbon steel enclosure, red or gray finish, 21”H x 14.35”W x 4”D, surface or flush mountable
  • Lockable door with viewing window
  • Enclosure can hold up to two 18 AH batteries
  • Two Class B detect circuits capable of sequential, cross‐ zone, or single detector release operation.
  • Maximum 25 detectors per detect circuit, 50 total.
  • Detect circuits are compatible with select System Sensor or Hochiki conventional detectors and bases
  • Detect circuits are compatible with linear heat detection cable or contact closure type devices
  • Three Class B input circuits for monitoring closed contact devices
  • Three Class B audible circuits for NAC devices, rated 2A per circuit
  • Agent Release circuit, six ARMs/IRMs maximum, any combination
  • Solenoid circuit, one 24V or two 12V solenoids. See Fike document 06‐186 for compatible devices.