Fike 10-063-1-R-2

$1,061.18

SHP-Pro Fire Alarm and Fire Suppression Releasing Control Panel; All Modes, Red Enclosure, 240V Operation

Availability: Estimated 18 days
Condition: New
Brand: Fike
Status: Active
SKU: 117722
Manufacturer Part #: 10-063-1-R-2

Description

The Fike SHP Pro is a compact, cost-effective, conventional fire alarm and suppression releasing panel. The SHP Pro is designed for use with Fike Clean Agent Fire Suppressant, CO2, sprinkler (preaction/deluge), or other industrial solenoid-based suppression systems. The SHP Pro controller is shipped from the factory pre configured for Clean Agent suppression operation.

Documents

Description

The Fike SHP Pro is a compact, cost-effective, conventional fire alarm and suppression releasing panel. The SHP Pro is designed for use with Fike Clean Agent Fire Suppressant, CO2, sprinkler (preaction/deluge), or other industrial solenoid-based suppression systems. The SHP Pro controller is shipped from the factory pre configured for Clean Agent suppression operation.

Additional information

Weight 30 lbs
Dimensions 21.00 × 14.35 × 4.00 in
Manufacturer

Fike Corporation

Brand

Condition

New

Unit of Measurement

EA (Each)

Production Status

Active

Model

SHP PRO

Type

Control Panel

Style

Conventional

Compatibility

10-063

Listings & Approvals

City of New York, CSFM, FM, Hong Kong, OSHPD, UL

SHP PRO® CONTROL PANEL

Download

Fike - Data Sheet

Conventional Fire Alarm and Suppression System

Download

Fike - Product Manual

SHP‐Pro® ENCLOSURE

Download

Fike - Installation Instructions

Attributes

Weight 30 lbs
Dimensions 21.00 × 14.35 × 4.00 in
Manufacturer

Fike Corporation

Brand

Condition

New

Unit of Measurement

EA (Each)

Production Status

Active

Model

SHP PRO

Type

Control Panel

Style

Conventional

Compatibility

10-063

Listings & Approvals

City of New York, CSFM, FM, Hong Kong, OSHPD, UL

Product Features

  • Ten system status LEDs (AC Normal, Alarm, PreDischarge, Release, Supervisory, Trouble, Panel Silenced, Abort, Release Disabled, Ground Fault)
  • General Alarm, Supervisory and Trouble relays
  • Dip‐switch panel configuration
  • Seven segment system status and diagnostic LED
  • Local sounder (piezo) with distinct event tones
  • Reset and Silence switches
  • Disable switch for audible, releasing and relays (hardware disconnect)
  • Alarm and Trouble silence resound (after 18 hrs.)
  • Five selectable abort types
  • Gentex or System Sensor sync protocol
  • Twenty event history buffer
  • Audibles selectable for slow, fast, continuous operation
  • Integral 24 VDC power supply, 1A standby/4A alarm
  • 120/240 VAC at 50/60 Hz power input
  • Resettable and non‐resettable 24 VDC power output
  • Battery and ground fault supervision
  • 7 – 40 AH battery charging capacity
  • Carbon steel enclosure, red or gray finish, 21”H x 14.35”W x 4”D, surface or flush mountable
  • Lockable door with viewing window
  • Enclosure can hold up to two 18 AH batteries
  • Two Class B detect circuits capable of sequential, cross‐ zone, or single detector release operation.
  • Maximum 25 detectors per detect circuit, 50 total.
  • Detect circuits are compatible with select System Sensor or Hochiki conventional detectors and bases
  • Detect circuits are compatible with linear heat detection cable or contact closure type devices
  • Three Class B input circuits for monitoring closed contact devices
  • Three Class B audible circuits for NAC devices, rated 2A per circuit
  • Agent Release circuit, six ARMs/IRMs maximum, any combination
  • Solenoid circuit, one 24V or two 12V solenoids. See Fike document 06‐186 for compatible devices.

What's Included

Shipping Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1 – 5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock. PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client.

Return Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee. New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made. See our complete return policy for more information at: https://firealarm.com/faq/

Testimonials

Rick A.
Dallas, TXI
Read More
"Great service. I received help with exactly what I needed and I received it all in a timely manner."
Charles O.
New Brunswick, NJ
Read More
"I had a big engineering/logistics issue that William over at FireAlarm.com helped me with. I don’t know what I would’ve done without their help!"
Jason G.
Los Angeles, CA
Read More
"The fastest delivery I’ve seen. Needed overnight emergency parts and I got just that."
Julia S.
Tampa, FL
Read More
"Needed last-minute maintenance done on my building’s system, and FireAlarm.com exceeded my expectations with how quickly it was done."

Leave a review

Pricing & Availability Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1 – 5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock. PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client.

Payment Details

You may remit payment via a US-Based Credit Card (CC Authorization Form), Wire Transfer (w/ $30 or $50 fee added to invoice), via PayPal (Or PayPal Pay Later), via Apple or Google Pay, or by mailing us a check. You can also call in with your credit card information at any time: 888-497-0290.

Return & Cancellation Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee. New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made. See our complete return policy for more information at: https://firealarm.com/faq/