Fire-Lite ECC-50DA

SKU: 30312
Manufacturer Part #: ECC-50DA
Condition: New
Brand: Fire-Lite
Status: Active

distributed audio amp 50wts 120v

$1,074.60

Availability: In Stock

Description

The Fire-Lite ECC-50DA is a 50 watt amplifier that can be used with the ECC-50/100(E) emergency voice evacuation system to offer additional audio power.

In large facilities where audio distribution is paramount, up to eight ECC-50DA units can be used to help distribute audio across vast areas. The amplifier supports Class A and B wiring, and is easy to setup thanks to a web-based programming utility. The amplifier comes in a durable cabinet and includes a built-in power supply and battery charger.

Documents

Description

The Fire-Lite ECC-50DA is a 50 watt amplifier that can be used with the ECC-50/100(E) emergency voice evacuation system to offer additional audio power.

In large facilities where audio distribution is paramount, up to eight ECC-50DA units can be used to help distribute audio across vast areas. The amplifier supports Class A and B wiring, and is easy to setup thanks to a web-based programming utility.

The amplifier comes in a durable cabinet and includes a built-in power supply and battery charger.

Attributes

Weight 2.80 lbs
Unit of Measurement

EA (Each)

Manufacturer

Honeywell

Condition

New

Brand

Fire-Lite

Production Status

Active

Listings & Approvals

CSFM, NYC, UL

Product Features

  • The ECC-50DA(E) and ECC-125DA(E) units come stan- dard with four onboard fully supervised speaker circuit zones, and are expandable to eight circuits when an optional ECC-CE4 module is added.
  • The ECC-50BDA includes eight onboard fully supervised speaker circuits/zones.
  • Any combination of up to eight ECC-50DA(E)s, ECC- 50BDAs, or ECC-125DA(E)s per system can be used with the ECC-50/100(E) for a total of 1100 watts of audio power and 24 speaker circuit outputs.
  • The ECC-50BDA can be used in the following configura- tions:

          – 50 Watts primary / 50 Watts back up

          – 100 watts primary / No back up

          – 100 watts primary / 50 Watts backup (Optional ECC- 50WBU required)

  • The ECC-50BDA supports the use of low frequency sound- ers per UL 464. Refer to the Device Compatibility Docu- ment #15384 for compatible devices.
  • Supports both Class A (Style Z) and Class B (Style Y) wir- ing.
  • Easy setup and configuration by using a simple, built-in web based programming utility on the ECC-50/100(E).
  • UL2572 (Communication and Control Units Mass Notifica- tion Systems). UL 864 (Emergency Voice Evacuation for Fire).
  • Built-in power supply and battery charger that supports up to 35AH. (For batteries larger than 18 AH, use the BB-26 or BB-55F Battery Box.)
  • ECC-50DA(E) and ECC-50BDA are field selectable for 25Vrms or 70.7Vrms of operation.
  • Sturdy, scratch resistant cabinet

Shipping Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1 – 5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock. PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client.

Return Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at sales@firealarm.com to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee. New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made. See our complete return policy for more information at: https://firealarm.com/faq/

Testimonials

Charles O.
New Brunswick, NJ
"I had a big engineering/logistics issue that William over at FireAlarm.com helped me with. I don’t know what I would’ve done without their help!"
Jason G.
Los Angeles, CA
"The fastest delivery I’ve seen. Needed overnight emergency parts and I got just that."
Julia S.
Tampa, FL
"Needed last-minute maintenance done on my building’s system, and FireAlarm.com exceeded my expectations with how quickly it was done."
Rick A.
Dallas, TXI
"Great service. I received help with exactly what I needed and I received it all in a timely manner."
Charles O.
New Brunswick, NJ
"I had a big engineering/logistics issue that William over at FireAlarm.com helped me with. I don’t know what I would’ve done without their help!"
Jason G.
Los Angeles, CA
"The fastest delivery I’ve seen. Needed overnight emergency parts and I got just that."
Julia S.
Tampa, FL
"Needed last-minute maintenance done on my building’s system, and FireAlarm.com exceeded my expectations with how quickly it was done."
Rick A.
Dallas, TXI
"Great service. I received help with exactly what I needed and I received it all in a timely manner."
Charles O.
New Brunswick, NJ
"I had a big engineering/logistics issue that William over at FireAlarm.com helped me with. I don’t know what I would’ve done without their help!"
Jason G.
Los Angeles, CA
"The fastest delivery I’ve seen. Needed overnight emergency parts and I got just that."

Leave a review

Reviews

There are no reviews yet.

Be the first to review “Fire-Lite ECC-50DA”