The Kidde GSA-M278 is an intelligent addressable double-action manual fire alarm pull station designed for use with Kidde Signature Series fire alarm systems. The device provides reliable manual fire alarm activation while integrating directly with Signature loop controllers for intelligent system communication and device diagnostics.

The double-action design requires users to lift the front cover and then pull the alarm handle, reducing the chance of accidental activation. The housing is constructed from durable red Lexan with clear markings for emergency operation. A keyed reset mechanism allows authorized personnel to reset the station after activation or testing.

The station includes an integral microprocessor that communicates directly with the Signature loop controller. Electronic addressing allows the system to automatically assign addresses during commissioning without manual switch settings. The device also stores operational data including maintenance history, alarm events, and device status to assist with system diagnostics and maintenance.

Documents

Description

The Kidde GSA-M278 is an intelligent addressable double-action manual fire alarm pull station designed for use with Kidde Signature Series fire alarm systems. The device provides reliable manual fire alarm activation while integrating directly with Signature loop controllers for intelligent system communication and device diagnostics.

The double-action design requires users to lift the front cover and then pull the alarm handle, reducing the chance of accidental activation. The housing is constructed from durable red Lexan with clear markings for emergency operation. A keyed reset mechanism allows authorized personnel to reset the station after activation or testing.

The station includes an integral microprocessor that communicates directly with the Signature loop controller. Electronic addressing allows the system to automatically assign addresses during commissioning without manual switch settings. The device also stores operational data including maintenance history, alarm events, and device status to assist with system diagnostics and maintenance.

Additional information

Weight 0.50 lbs
Dimensions 5.50 × 3.00 × 2.00 in
Manufacturer

UTC Fire & Security

Brand

Kidde

Condition

New

Unit of Measurement

EA (Each)

Type

Pull Station

Color

Red

Operation

Dual-Action

Production Status

Active

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

Attributes

Additional information

Weight 0.50 lbs
Dimensions 5.50 × 3.00 × 2.00 in
Manufacturer

UTC Fire & Security

Brand

Kidde

Condition

New

Unit of Measurement

EA (Each)

Type

Pull Station

Color

Red

Operation

Dual-Action

Production Status

Active

Product Features

• Intelligent addressable manual pull station for Signature Series systems
• Double-action operation: lift cover then pull handle to activate alarm
• Integrated microprocessor improves response and communication reliability
• Electronic addressing with non-volatile memory
• Automatic device mapping reports wiring location to the loop controller
• On-board LEDs indicate polling status and alarm condition
• Keyed reset mechanism for maintenance and testing
• Durable red Lexan housing with clear fire alarm markings
• Designed for ambient temperatures up to 120°F (49°C)
• ADA compliant manual fire alarm station

What's Included

• GSA-M278 addressable manual pull station
• Reset key

Shipping Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1–5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock.

PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client. This product may be sourced from the manufacturer or supplier. If so, manufacturer cancellation fees may apply if the order is cancelled after processing. See our Terms of Sale for details.

Return Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee.

New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made.

Testimonials

Rick A.
Dallas, TXI
"Great service. I received help with exactly what I needed and I received it all in a timely manner."
Charles O.
New Brunswick, NJ
"I had a big engineering/logistics issue that William over at FireAlarm.com helped me with. I don’t know what I would’ve done without their help!"
Jason G.
Los Angeles, CA
"The fastest delivery I’ve seen. Needed overnight emergency parts and I got just that."
Julia S.
Tampa, FL
"Needed last-minute maintenance done on my building’s system, and FireAlarm.com exceeded my expectations with how quickly it was done."

Leave a review

Edwards Signaling 276-GLR Replacement Glass Rods (20 pack)
Mfr. Part #: 276-GLR
SKU: 5110
On Backorder
Estimated 5 business days

$28.49

Pricing & Availability Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1 – 5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock. PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client.

Payment Details

You may remit payment via a US-Based Credit Card (CC Authorization Form), Wire Transfer (w/ $30 or $50 fee added to invoice), via PayPal (Or PayPal Pay Later), via Apple or Google Pay, or by mailing us a check. You can also call in with your credit card information at any time: 888-497-0290.

Return & Cancellation Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee. New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made. See our complete return policy for more information at: https://firealarm.com/faq/