Notifier TM-4

SKU: 68198
Manufacturer Part #: TM-4
Condition: New
Brand: Notifier
Status: Active

Transmitter Module

On Backorder

Description

The TM-4 Transmitter Module provides NOTIFIER’s NFS2-3030, NFS-3030, NFS2-640, NFS-640 and the NFS-320. Fire Alarm Control Panels, and NCA-2 and NCA Network Control Annunciators with three reverse-polarity outputs (alarm, trouble, and supervisory) and one fire municipal box trip on a single PC board. The TM-4 is designed to meet NFPA 72 requirements for Auxiliary Protective Signaling Systems and Remote Station Protective Signaling Systems.

Documents

Description

The TM-4 Transmitter Module provides NOTIFIER’s NFS2-3030, NFS-3030, NFS2-640, NFS-640 and the NFS-320. Fire Alarm Control Panels, and NCA-2 and NCA Network Control Annunciators with three reverse-polarity outputs (alarm, trouble, and supervisory) and one fire municipal box trip on a single PC board. The TM-4 is designed to meet NFPA 72 requirements for Auxiliary Protective Signaling Systems and Remote Station Protective Signaling Systems.

Additional information

Weight 1 lbs
Dimensions 4.37 × 6.87 in
Compatibility

, ,

Manufacturer

Honeywell International

Condition

New

Unit of Measurement

EA (Each)

Brand

Notifier

Production Status

Active

Listings & Approvals

City of Chicago, City of Denver, CSFM, FDNY Approved, FM, Lloyd’s Register, MEA, U.S. Coast Guard, UL, ULC

Reviews

There are no reviews yet.

Be the first to review “Notifier TM-4”

TM-4 ONYX® Series Transmitter Modules

Download

Notifier - Data Sheet

Attributes

Weight 1 lbs
Dimensions 4.37 × 6.87 in
Compatibility

, ,

Manufacturer

Honeywell International

Condition

New

Unit of Measurement

EA (Each)

Brand

Notifier

Production Status

Active

Listings & Approvals

City of Chicago, City of Denver, CSFM, FDNY Approved, FM, Lloyd’s Register, MEA, U.S. Coast Guard, UL, ULC

Product Features

  • On each TM-4 module in a system, use either the three reverse-polarity outputs (alarm, trouble, and supervisory) or the fire municipal box trip.
  • Maximum load for each reverse-polarity output circuit is 15 mA, 24 VDC nominal. All circuits are power cross-rated and power-limited per UL 1950 requirements.
  • Mounts on CHS Series chassis and in panel module locations.
  • Diagnostic LEDs: green for Power, ACS Data Reception and ACS Data Transmission; yellow for Trouble.
  • Isolated 24 V for reverse-polarity outputs.
  • Disconnect mechanism provides a means for inhibiting alarm status changes, which cause trouble indication for unit at the Fire Alarm Control Panel (FACP). Operation of the disconnect mechanism will also create a trouble condition on the reverse-polarity output circuits.
  • Option jumper combines alarm and trouble conditions onto one circuit.

What's Included

Shipping Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1 – 5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock. PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client.

Return Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee. New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made. See our complete return policy for more information at: https://firealarm.com/faq/

Testimonials

Rick A.
Dallas, TXI
"Great service. I received help with exactly what I needed and I received it all in a timely manner."
Charles O.
New Brunswick, NJ
"I had a big engineering/logistics issue that William over at FireAlarm.com helped me with. I don’t know what I would’ve done without their help!"
Jason G.
Los Angeles, CA
"The fastest delivery I’ve seen. Needed overnight emergency parts and I got just that."
Julia S.
Tampa, FL
"Needed last-minute maintenance done on my building’s system, and FireAlarm.com exceeded my expectations with how quickly it was done."

Leave a review

Reviews

There are no reviews yet.

Be the first to review “Notifier TM-4”

You may also like...

Pricing & Availability Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1 – 5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock. PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client.

Payment Details

You may remit payment via a US-Based Credit Card (CC Authorization Form), Wire Transfer (w/ $30 or $50 fee added to invoice), via PayPal (Or PayPal Pay Later), via Apple or Google Pay, or by mailing us a check. You can also call in with your credit card information at any time: 888-497-0290.

Return & Cancellation Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee. New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made. See our complete return policy for more information at: https://firealarm.com/faq/