Potter AFC-100

$1,058.86

Analog Addressable Fire Alarm Control Panel

Availability: Estimated 14 days
Condition: New
Brand: Potter
Status: Active
SKU: 46972
Manufacturer Part #: AFC-100
Secondary Part #: 3992753

Description

The AFC-100 is an analog/addressable fire alarm system with a total system capacity of 100 addresses. Additional capacity on the system is achieved using multi-point SLC modules. The control panel utilizes the exclusive Potter protocol that includes a complete line of sensors and modules. Each SLC may be comprised of any combination of smoke sensor, heat detectors or modules and allows for a total of 50 ohms of impedance and may use any wire compliant with the National Electrical Code (NEC). The AFC-100 has a 5 Amp power supply with two Notification Appliance Circuits (NACs) and two Input/Output (I/O) circuits. The NACs are rated at 3 Amps each and the I/Os are rated at 1 Amp each. Each output is regulated and power limited. In addition, each output is uniquely programmable and may be configured for steady signal, strobe synchronization, constant power, door holder power, or releasing. The strobe synchronization includes Gentex, AMSECO, System Sensor and Cooper/Wheelock and with the exclusive Quadrasync each output may have a unique brand and all strobes will flash together. The NACs may be expanded using the PSN-1000 series intelligent power supplies. Each PSN-1000 adds another 10 Amps of power, 2 additional input circuits and the AFC-100 will support up to 31 power supplies. The system will synchronize the strobes system wide. In addition, the PSN-1000E has space to allow the installation of up to six loop expansion cards. The cards mount on a stacker bracket that allows access to all SLC circuit connections.

Documents

Description

The AFC-100 is an analog/addressable fire alarm system with a total system capacity of 100 addresses. Additional capacity on the system is achieved using multi-point SLC modules. The control panel utilizes the exclusive Potter protocol that includes a complete line of sensors and modules. Each SLC may be comprised of any combination of smoke sensor, heat detectors or modules and allows for a total of 50 ohms of impedance and may use any wire compliant with the National Electrical Code (NEC).

The AFC-100 has a 5 Amp power supply with two Notification Appliance Circuits (NACs) and two Input/Output (I/O) circuits. The NACs are rated at 3 Amps each and the I/Os are rated at 1 Amp each. Each output is regulated and power limited. In addition, each output is uniquely programmable and may be configured for steady signal, strobe synchronization, constant power, door holder power, or releasing. The strobe synchronization includes Gentex, AMSECO, System Sensor and Cooper/Wheelock and with the exclusive Quadrasync each output may have a unique brand and all strobes will flash together.

The NACs may be expanded using the PSN-1000 series intelligent power supplies. Each PSN-1000 adds another 10 Amps of power, 2 additional input circuits and the AFC-100 will support up to 31 power supplies. The system will synchronize the strobes system wide. In addition, the PSN-1000E has space to allow the installation of up to six loop expansion cards. The cards mount on a stacker bracket that allows access to all SLC circuit connections.

Additional information

Weight 16 lbs
Dimensions 16.00 × 17.00 × 3.75 in
Manufacturer

Potter Electric Signal Company, LLC

Brand

Condition

New

Unit of Measurement

EA (Each)

Production Status

Active

Type

Control Panel

Style

Addressable

Color

Red

Series

Compatibility

AFC-100

Reviews

There are no reviews yet.

Be the first to review “Potter AFC-100”

AFC-100: Fire Alarm Control Panel

Download

Potter - Data Sheet

AFC-100: Fire Alarm Installation Manual

Download

Potter - Installation Manual

Attributes

Weight 16 lbs
Dimensions 16.00 × 17.00 × 3.75 in
Manufacturer

Potter Electric Signal Company, LLC

Brand

Condition

New

Unit of Measurement

EA (Each)

Production Status

Active

Type

Control Panel

Style

Addressable

Color

Red

Series

Compatibility

AFC-100

Product Features

  • 100 addresses available on this analog addressable system
  • Additional system capacity achieved via multi-point SLC modules
  • 99 software zones
  • NFPA 72 Compliant Smoke Sensitivity Test Built-In
  • System Operates as Class A or Class B for SLC, P-Link and NACs
  • 5 Amp Power Supply, Expandable to 310 amps
  • 2 NACS, Regulated, Rated at 3 Amps each, expandable to 188
  • 2 Input/Output (I/O) Circuits for system flexibility rated at 1 Amp each
  • Strobe Synchronization and System Wide Sync for Gentex®, AMSECO®, Cooper Wheelock® and System Sensor® strobes
  • Dedicated Alarm, Supervisory and Trouble Relays
  • 4,000 Event History Buffer
  • Optional two line DACT with UD-2000 that can report General, Zone or Point Information
  • Built in IP Communicator
  • Ethernet Port for Programming and Network Connectivity
  • E-Mail System Status, Reports and Event Information

What's Included

Shipping Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1 – 5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock. PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client.

Return Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee. New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made. See our complete return policy for more information at: https://firealarm.com/faq/

Testimonials

Rick A.
Dallas, TXI
Read More
"Great service. I received help with exactly what I needed and I received it all in a timely manner."
Charles O.
New Brunswick, NJ
Read More
"I had a big engineering/logistics issue that William over at FireAlarm.com helped me with. I don’t know what I would’ve done without their help!"
Jason G.
Los Angeles, CA
Read More
"The fastest delivery I’ve seen. Needed overnight emergency parts and I got just that."
Julia S.
Tampa, FL
Read More
"Needed last-minute maintenance done on my building’s system, and FireAlarm.com exceeded my expectations with how quickly it was done."

Leave a review

Reviews

There are no reviews yet.

Be the first to review “Potter AFC-100”

Pricing & Availability Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1 – 5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock. PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client.

Payment Details

You may remit payment via a US-Based Credit Card (CC Authorization Form), Wire Transfer (w/ $30 or $50 fee added to invoice), via PayPal (Or PayPal Pay Later), via Apple or Google Pay, or by mailing us a check. You can also call in with your credit card information at any time: 888-497-0290.

Return & Cancellation Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee. New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made. See our complete return policy for more information at: https://firealarm.com/faq/