Safe Fire Detection 61986104-FMULOP1 ProPoint Plus Smoke Detector, 1 Pipe

SKU: 283313
Manufacturer Part #: 61986104-FMULOP1
Condition: New
Brand: Safe Fire Detection
Status: Active

$3,111.00

Estimated 14 business days
On Backorder
Join FireAlarm Plus to reduce your cost per unit and gain faster access to inventory on this purchase.

Description

Aspirating detection is now a recognised solution for many different fire detection applications. ProPoint PLUS provides up to four separate detectors within a common aspirator enclosure and therefore provides four individually identifiable areas of detection per aspirator.

Each of the four plug-in ‘Scatter Chamber Detectors’ (SCD)’s detector modules can be either ‘optical’ only or combined ‘optical/enhanced CO’ detectors, the CO sensor is only suitable for small room applications. Independent and integrated alarm decision making through the use of complex algorithms extend the range of particle detection, confirm genuine alarms and reduce unwanted alarms.

Installation, configuration and commissioning of ProPoint PLUS detectors is very simple and installer friendly.

Configuration to either Class A, Class B or Class C sensitivity options is achieved through a multi-language, multi-function LCD display without the need for a laptop connection.

Detector set up allows the installer to configure the detector sensitivity to an equivalent setting, as a known number of point type smoke detectors for each Class A, Class B and Class C system. This ensures the system specifier, designer, installer and commissioning engineer configure the ProPoint PLUS SCD’s to the correct sensitivity for the particular application.

Aspirator fan speed and airflow configuration is a also a very simple process allowing ProPoint PLUS aspirating detectors to be installed in a variety of applications with short and relatively long pipe runs.

Documents

Description

Aspirating detection is now a recognised solution for many different fire detection applications. ProPoint PLUS provides up to four separate detectors within a common aspirator enclosure and therefore provides four individually identifiable areas of detection per aspirator.

Each of the four plug-in ‘Scatter Chamber Detectors’ (SCD)’s detector modules can be either ‘optical’ only or combined ‘optical/enhanced CO’ detectors, the CO sensor is only suitable for small room applications. Independent and integrated alarm decision making through the use of complex algorithms extend the range of particle detection, confirm genuine alarms and reduce unwanted alarms.

Installation, configuration and commissioning of ProPoint PLUS detectors is very simple and installer friendly.

Configuration to either Class A, Class B or Class C sensitivity options is achieved through a multi-language, multi-function LCD display without the need for a laptop connection.

Detector set up allows the installer to configure the detector sensitivity to an equivalent setting, as a known number of point type smoke detectors for each Class A, Class B and Class C system. This ensures the system specifier, designer, installer and commissioning engineer configure the ProPoint PLUS SCD’s to the correct sensitivity for the particular application.

Aspirator fan speed and airflow configuration is a also a very simple process allowing ProPoint PLUS aspirating detectors to be installed in a variety of applications with short and relatively long pipe runs.

Additional information

Weight 6.6 lbs
Dimensions 14.96 × 9.84 × 5.39 in
Manufacturer

Protec Fire Detection PLC

Brand

Safe Fire Detection

Condition

New

Unit of Measurement

EA (Each)

Production Status

Active

Listings & Approvals

CE, CSFM, cUL, FM Approved, UL

Supply Voltage

21 – 29VDC

IP Rating

IP20

Pipe ID

3/4” or 25mm

Alarm Indications

Pre-alarm warning and Fire per pipe

Coverage

Up to 54,000sq.ft.

Sample Points

Up to 60

Relevant Standard

EN54 Part 17 & 20, AS 7240 Part 20

ProPointPlus Early Warning Aspirating Fire Detector

Download

Safe Fire Detection - Data Sheet

Early Warning Air Sampling Smoke Detection ProPointPlus

Download

Safe Fire Detection - Engineering Specification

ProPointPlus

Download

Safe Fire Detection - Start-up Guide

ProPointPlus

Download

Safe Fire Detection - Maintenance Guide

Attributes

Additional information

Weight 6.6 lbs
Dimensions 14.96 × 9.84 × 5.39 in
Manufacturer

Protec Fire Detection PLC

Brand

Safe Fire Detection

Condition

New

Unit of Measurement

EA (Each)

Production Status

Active

Listings & Approvals

CE, CSFM, cUL, FM Approved, UL

Supply Voltage

21 – 29VDC

IP Rating

IP20

Pipe ID

3/4” or 25mm

Alarm Indications

Pre-alarm warning and Fire per pipe

Coverage

Up to 54,000sq.ft.

Sample Points

Up to 60

Relevant Standard

EN54 Part 17 & 20, AS 7240 Part 20

Product Features

• 1 – 4 Individual detectors per aspirator(providing up to 4 separately identifiable areas)
• High performance optical ‘Scatter Chamber Detectors’ (SCD)
• Multiple language, multi-function LCD display
• Simple install and commission process generally without the need for a laptop connection
• Built-In algorithm to reduce unwanted alarms
• Airflow monitoring per pipe

What's Included

Shipping Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1–5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock.

PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client. This product may be sourced from the manufacturer or supplier. If so, manufacturer cancellation fees may apply if the order is cancelled after processing. See our Terms of Sale for details.

Return Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee.

New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made.

Testimonials

Rick A.
Dallas, TXI
"Great service. I received help with exactly what I needed and I received it all in a timely manner."
Charles O.
New Brunswick, NJ
"I had a big engineering/logistics issue that William over at FireAlarm.com helped me with. I don’t know what I would’ve done without their help!"
Jason G.
Los Angeles, CA
"The fastest delivery I’ve seen. Needed overnight emergency parts and I got just that."
Julia S.
Tampa, FL
"Needed last-minute maintenance done on my building’s system, and FireAlarm.com exceeded my expectations with how quickly it was done."

Leave a review

Pricing & Availability Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1 – 5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock. PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client.

Payment Details

You may remit payment via a US-Based Credit Card (CC Authorization Form), Wire Transfer (w/ $30 or $50 fee added to invoice), via PayPal (Or PayPal Pay Later), via Apple or Google Pay, or by mailing us a check. You can also call in with your credit card information at any time: 888-497-0290.

Return & Cancellation Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee. New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made. See our complete return policy for more information at: https://firealarm.com/faq/