Description

Cirrus HYBRID is the only aspirating detector available to identify the optically invisible fire particulate by utilising the unique ‘Cloud Chamber Detection’ (CCD) technology.

Combined Cloud Chamber ‘Fire’ and optical ‘Smoke’ detection.

History tells us that in reality there are really only two types of aspirating detector technology. These technologies are ‘Cloud Chamber’ aspirating detection identifying optically invisible fire particulate, and laser or LED ‘Optical’ aspirating detection identifying small amounts of visible smoke.

Depending on the materials burning, particularly in the many modern applications for aspirating detection systems, some fires burn with only a small amount of visible smoke, whereas others burn with greater volumes of visible smoke.

Cirrus HYBRID detects these wide-ranging ‘smokier’ fire types too. Early Warning Smoke Detection (EWSD) is provided using high performance optical ‘Scatter Chamber Detectors’ (SCD) that identify both small and larger smoke particles entering the detector.

By utilising the two most effective methods of aspirating system technologies (CCD and EWSD) in a single detector the Cirrus HYBRID detector provides a device able to detect fire and smoke over the largest range of fire types.

However, what makes this totally new and genuinely unique concept in aspirating fire and smoke detection technology so different is that these two technologies work both independently from each other, and through the use of complex algorithms also interact together, to provide true intelligent alarm decision making. The result of this synergy of technologies is a device that can verify true alarm conditions across the largest range of fire types. A further and equally as important result of this synergy of technologies, is the discrimination of unwanted or false alarms which have historically and still continue to plague so many optical only aspirating detectors.

Documents

Description

Cirrus HYBRID is the only aspirating detector available to identify the optically invisible fire particulate by utilising the unique ‘Cloud Chamber Detection’ (CCD) technology.

Combined Cloud Chamber ‘Fire’ and optical ‘Smoke’ detection.

History tells us that in reality there are really only two types of aspirating detector technology. These technologies are ‘Cloud Chamber’ aspirating detection identifying optically invisible fire particulate, and laser or LED ‘Optical’ aspirating detection identifying small amounts of visible smoke.

Depending on the materials burning, particularly in the many modern applications for aspirating detection systems, some fires burn with only a small amount of visible smoke, whereas others burn with greater volumes of visible smoke.

Cirrus HYBRID detects these wide-ranging ‘smokier’ fire types too. Early Warning Smoke Detection (EWSD) is provided using high performance optical ‘Scatter Chamber Detectors’ (SCD) that identify both small and larger smoke particles entering the detector.

By utilising the two most effective methods of aspirating system technologies (CCD and EWSD) in a single detector the Cirrus HYBRID detector provides a device able to detect fire and smoke over the largest range of fire types.

However, what makes this totally new and genuinely unique concept in aspirating fire and smoke detection technology so different is that these two technologies work both independently from each other, and through the use of complex algorithms also interact together, to provide true intelligent alarm decision making. The result of this synergy of technologies is a device that can verify true alarm conditions across the largest range of fire types. A further and equally as important result of this synergy of technologies, is the discrimination of unwanted or false alarms which have historically and still continue to plague so many optical only aspirating detectors.

Additional information

Weight 7.7 lbs
Dimensions 14.96 × 9.84 × 5.39 in
Manufacturer

Protec Fire Detection PLC

Brand

Safe Fire Detection

Condition

New

Unit of Measurement

EA (Each)

Production Status

Active

Listings & Approvals

CE, CSFM, cULus, FM Approved, UL

Supply Voltage

20 – 29VDC

IP Rating

IP30

Pipe ID

3/4" or 25mm

Alarm Indications

Pre-alarm, Fire 1, Fire 2, Fire 3

Sample Points

Up to 64 Holes

Sensitivity Range

10,000 PCC to 10 million PCC
0 – 1000CFS (Combined Fire & Smoke scale)

Camera Inputs

6 x Protec specified IP cameras

Coverage

Up to 57,600sq.ft.

Cirrus HYBRID Air Sampling Fire and Smoke Detection

Download

Safe Fire Detection - Catalog

Cirrus Hybrid Very Early Warning Aspirating Fire Detector

Download

Safe Fire Detection - Data Sheet

Very Early Warning Air Sampling Fire and Smoke Detection Cirrus Hybrid (non-scanning)

Download

Sage Fire Detection - Engineering Specification

Cirrus Hybrid

Download

Safe Fire Detection - Start-Up Guide

Cirrus Hybrid

Download

Safe Fire Detection - Maintenance Guide

Attributes

Additional information

Weight 7.7 lbs
Dimensions 14.96 × 9.84 × 5.39 in
Manufacturer

Protec Fire Detection PLC

Brand

Safe Fire Detection

Condition

New

Unit of Measurement

EA (Each)

Production Status

Active

Listings & Approvals

CE, CSFM, cULus, FM Approved, UL

Supply Voltage

20 – 29VDC

IP Rating

IP30

Pipe ID

3/4" or 25mm

Alarm Indications

Pre-alarm, Fire 1, Fire 2, Fire 3

Sample Points

Up to 64 Holes

Sensitivity Range

10,000 PCC to 10 million PCC
0 – 1000CFS (Combined Fire & Smoke scale)

Camera Inputs

6 x Protec specified IP cameras

Coverage

Up to 57,600sq.ft.

Product Features

• The First and Only “Combined Fire & Smoke” Aspirating Detector
• Unique “Cloud Chamber Detection” (CCD) – Primary Detection Technology
• Optical “Scattering Chamber Detectors” (SCD) – Secondary Detection Technology
• Independent and integrated intelligent alarm signal decision making
• The largest sensitivity range of any aspirating detector 0%obs/m – 20%obs/m
• HYBRID “Smart Signal” to verify alarms and discriminate false alarms
• 7” full color multi-function touchscreen LCD Display
• Live Camera Stream from up to 6 IP color cameras
• Built-In Troubleshooting Videos

What's Included

Shipping Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1–5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock.

PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client. This product may be sourced from the manufacturer or supplier. If so, manufacturer cancellation fees may apply if the order is cancelled after processing. See our Terms of Sale for details.

Return Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee.

New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made.

Testimonials

Rick A.
Dallas, TXI
"Great service. I received help with exactly what I needed and I received it all in a timely manner."
Charles O.
New Brunswick, NJ
"I had a big engineering/logistics issue that William over at FireAlarm.com helped me with. I don’t know what I would’ve done without their help!"
Jason G.
Los Angeles, CA
"The fastest delivery I’ve seen. Needed overnight emergency parts and I got just that."
Julia S.
Tampa, FL
"Needed last-minute maintenance done on my building’s system, and FireAlarm.com exceeded my expectations with how quickly it was done."

Leave a review

Pricing & Availability Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1 – 5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock. PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client.

Payment Details

You may remit payment via a US-Based Credit Card (CC Authorization Form), Wire Transfer (w/ $30 or $50 fee added to invoice), via PayPal (Or PayPal Pay Later), via Apple or Google Pay, or by mailing us a check. You can also call in with your credit card information at any time: 888-497-0290.

Return & Cancellation Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee. New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made. See our complete return policy for more information at: https://firealarm.com/faq/