Siemens ADAPT-PLATE

SKU: 121520
Manufacturer Part #: ADAPT-PLATE
Secondary Part #: 500-618020
Condition: New
Brand: Siemens
Status: Active

Adapter Plate

Currently Unavailable
Join FireAlarm Plus to reduce your cost per unit and gain faster access to inventory on this purchase.

Description

Designed for use with either standard Fire Safety systems or other commercially available fire alarm systems, the DT-135CL, DT-200CL, DT-135CS, DT-200CS, DT-135WP and DT-200WP Thermal Fire Detectors are of the rate compensation/fixed temperature type and are In all models the detector element is self-restoring after operation and is supplied in ratings of 135°F and 200°F. While UL recommends the Thermal Detector be used to protect a maximum of 2,500 square feet, job conditions and engineering judgment often dictate closer spacing to provide faster detection. The Models DT-135CL and DT-200CL are used with Fire Safety low voltage systems where it is desirable to provide visual identification of an operated detector by means of an internally mounted incandescent lamp. These models lock in upon alarm and must be reset at the control panel. The Models DT-135CS, DT-135WP, DT-200WP and DT-200CS can be used with any fire alarm circuit of any manufacturer using open circuit direct shorting type units. These units do not contain a series-connected resistor or an indicator lamp and do not lock in upon alarm. Contact ratings are 6-125 VAC, 5 A; 6-25 VDC, 1 A125VDC, 0.5 A. The DT 135WP and DT-200WP are both UL listed and US Coast Guard approved as weatherproof. They are furnished with leads through a 1/2" NPT hub that screws into a standard W.P. junction box cover with an epoxy-coated shell. UL and ULC Listed*, and NYMEA, CSFM and City of Chicago Approved*. *Pending Adapter Plate only.

Documents

Description

Designed for use with either standard Fire Safety systems or other commercially available fire alarm systems, the DT-135CL, DT-200CL, DT-135CS, DT-200CS, DT-135WP and DT-200WP Thermal Fire Detectors are of the rate compensation/fixed temperature type and are In all models the detector element is self-restoring after operation and is supplied in ratings of 135°F and 200°F. While UL recommends the Thermal Detector be used to protect a maximum of 2,500 square feet, job conditions and engineering judgment often dictate closer spacing to provide faster detection. The Models DT-135CL and DT-200CL are used with Fire Safety low voltage systems where it is desirable to provide visual identification of an operated detector by means of an internally mounted incandescent lamp. These models lock in upon alarm and must be reset at the control panel. The Models DT-135CS, DT-135WP, DT-200WP and DT-200CS can be used with any fire alarm circuit of any manufacturer using open circuit direct shorting type units. These units do not contain a series-connected resistor or an indicator lamp and do not lock in upon alarm. Contact ratings are 6-125 VAC, 5 A; 6-25 VDC, 1 A125VDC, 0.5 A. The DT 135WP and DT-200WP are both UL listed and US Coast Guard approved as weatherproof. They are furnished with leads through a 1/2″ NPT hub that screws into a standard W.P. junction box cover with an epoxy-coated shell. UL and ULC Listed*, and NYMEA, CSFM and City of Chicago Approved*. *Pending Adapter Plate only.

Additional information

Weight 0.2 lbs
Manufacturer

Siemens Industry, Inc.

Brand

Siemens

Condition

New

Unit of Measurement

EA (Each)

Production Status

Active

Attributes

Additional information

Weight 0.2 lbs
Manufacturer

Siemens Industry, Inc.

Brand

Siemens

Condition

New

Unit of Measurement

EA (Each)

Production Status

Active

Product Features

What's Included

Shipping Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1–5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock.

PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client. This product may be sourced from the manufacturer or supplier. If so, manufacturer cancellation fees may apply if the order is cancelled after processing. See our Terms of Sale for details.

Return Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee.

New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made.

Testimonials

Rick A.
Dallas, TXI
"Great service. I received help with exactly what I needed and I received it all in a timely manner."
Charles O.
New Brunswick, NJ
"I had a big engineering/logistics issue that William over at FireAlarm.com helped me with. I don’t know what I would’ve done without their help!"
Jason G.
Los Angeles, CA
"The fastest delivery I’ve seen. Needed overnight emergency parts and I got just that."
Julia S.
Tampa, FL
"Needed last-minute maintenance done on my building’s system, and FireAlarm.com exceeded my expectations with how quickly it was done."

Leave a review

Pricing & Availability Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1 – 5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock. PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client.

Payment Details

You may remit payment via a US-Based Credit Card (CC Authorization Form), Wire Transfer (w/ $30 or $50 fee added to invoice), via PayPal (Or PayPal Pay Later), via Apple or Google Pay, or by mailing us a check. You can also call in with your credit card information at any time: 888-497-0290.

Return & Cancellation Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee. New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made. See our complete return policy for more information at: https://firealarm.com/faq/