Siemens FDBZ492-HR Two Wire Duct Detector With Relays

SKU: 4596
Manufacturer Part #: FDBZ492-HR
Secondary Part #: S54319-B22-A1
Condition: New
Brand: Siemens
Status: Active
Note: This listing is for a duct-housing ONLY. Smoke head is sold separately.

Two Wire Duct Detector, Relays, Low Flow HVAC

$256.99

Ships in 8 business days
Limited Stock
Join FireAlarm Plus to reduce your cost per unit and gain faster access to inventory on this purchase.

Description

The FDBZ492-HR is a two-wire addressable air duct monitoring housing with a built-in programmable relay base. Designed for direct mounting to HVAC duct systems, it detects smoke and combustion products circulating through supply and return air ducts. The housing draws a cross-sectional air sample through an inlet sampling tube, passes it over a compatible smoke detector mounted inside, and exhausts the sample back into the duct through an outlet tube.

The relay output provides Form C dry contacts rated at 125 VAC / 24 VDC, 2.5A for direct HVAC shutdown or activation of supplementary control equipment. The FDBZ492-HR works with Siemens H-series and FD-series addressable detectors including the HFP-11, HFPO-11, SFP-11, SFPO-11, FP-11/FP-11C, 8710, 8713, FDO421, FDOOT441, FDOOTC441, OP921, OOH941, and OOHC941. Cover removal switches (SW1, SW2) generate an immediate trouble condition when the clear cover is removed, and a tri-color LED on the detector indicates normal (green), trouble (yellow), or alarm (red) status.

The unit mounts to the side, bottom, or top of a duct and supports air velocities from 100 to 4,000 ft/min. Inlet sampling tubes are available in four lengths for duct widths from 6 inches to 10 feet. An optional FDBZ492-RTL remote test switch enables manual relay-output control and status indication from a remote location.

Documents

Description

The FDBZ492-HR is a two-wire addressable air duct monitoring housing with a built-in programmable relay base. Designed for direct mounting to HVAC duct systems, it detects smoke and combustion products circulating through supply and return air ducts. The housing draws a cross-sectional air sample through an inlet sampling tube, passes it over a compatible smoke detector mounted inside, and exhausts the sample back into the duct through an outlet tube.

The relay output provides Form C dry contacts rated at 125 VAC / 24 VDC, 2.5A for direct HVAC shutdown or activation of supplementary control equipment. The FDBZ492-HR works with Siemens H-series and FD-series addressable detectors including the HFP-11, HFPO-11, SFP-11, SFPO-11, FP-11/FP-11C, 8710, 8713, FDO421, FDOOT441, FDOOTC441, OP921, OOH941, and OOHC941. Cover removal switches (SW1, SW2) generate an immediate trouble condition when the clear cover is removed, and a tri-color LED on the detector indicates normal (green), trouble (yellow), or alarm (red) status.

The unit mounts to the side, bottom, or top of a duct and supports air velocities from 100 to 4,000 ft/min. Inlet sampling tubes are available in four lengths for duct widths from 6 inches to 10 feet. An optional FDBZ492-RTL remote test switch enables manual relay-output control and status indication from a remote location.

Additional information

Weight 1.8 lbs
Dimensions 2.50 × 5.00 × 14.38 in
Manufacturer

Siemens Industry, Inc.

Brand

Siemens

Condition

New

Unit of Measurement

EA (Each)

Production Status

Active

Type

Addressable, Duct Detector

Operating Temperature Range

32°F to 120°F (0°C to 49°C)

Humidity Rating

0–95% RH, non-condensing

Series

Listings & Approvals

CSFM, FM, UL, ULC

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

Attributes

Additional information

Weight 1.8 lbs
Dimensions 2.50 × 5.00 × 14.38 in
Manufacturer

Siemens Industry, Inc.

Brand

Siemens

Condition

New

Unit of Measurement

EA (Each)

Production Status

Active

Type

Addressable, Duct Detector

Operating Temperature Range

32°F to 120°F (0°C to 49°C)

Humidity Rating

0–95% RH, non-condensing

Series

Listings & Approvals

CSFM, FM, UL, ULC

Product Features

  • Built-in Form C relay contacts for direct HVAC shutdown control
  • Compatible with Siemens H-series, FD-series, and FP-11 addressable detectors
  • Cross-sectional air sampling covers full duct width via notched inlet tube
  • Cover tamper switches generate instant trouble on cover removal
  • Tri-color LED visible through clear cover indicates normal, trouble, and alarm states
  • Supports air velocities from 100 to 4,000 ft/min without sensitivity loss
  • Optional FDBZ492-RTL remote test switch for manual relay control and status monitoring
  • Optional NEMA 4X watertight enclosure (FDBZ-WT) for outdoor or high-moisture environments
  • Tool-free cover removal via four captive thumb screws
  • Smoke test port built into the housing cover for functional testing

What's Included

  • Air duct housing with programmable relay base
  • Short return (outlet) sampling tube
  • Red stopper
  • Two #12 × 3/4″ sheet metal screws
  • Mounting template
  • Installation Sheet

Shipping Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1–5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock.

PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client. This product may be sourced from the manufacturer or supplier. If so, manufacturer cancellation fees may apply if the order is cancelled after processing. See our Terms of Sale for details.

Return Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee.

New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made.

Testimonials

Rick A.
Dallas, TXI
"Great service. I received help with exactly what I needed and I received it all in a timely manner."
Charles O.
New Brunswick, NJ
"I had a big engineering/logistics issue that William over at FireAlarm.com helped me with. I don’t know what I would’ve done without their help!"
Jason G.
Los Angeles, CA
"The fastest delivery I’ve seen. Needed overnight emergency parts and I got just that."
Julia S.
Tampa, FL
"Needed last-minute maintenance done on my building’s system, and FireAlarm.com exceeded my expectations with how quickly it was done."

Leave a review

Pricing & Availability Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1 – 5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock. PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client.

Payment Details

You may remit payment via a US-Based Credit Card (CC Authorization Form), Wire Transfer (w/ $30 or $50 fee added to invoice), via PayPal (Or PayPal Pay Later), via Apple or Google Pay, or by mailing us a check. You can also call in with your credit card information at any time: 888-497-0290.

Return & Cancellation Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee. New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made. See our complete return policy for more information at: https://firealarm.com/faq/