Simplex 4098-9754 TrueAlarm Multi Sensor Detector

SKU: 9670
Manufacturer Part #: 4098-9754
Condition: New
Brand: Simplex
Status: Discontinued

TrueAlarm Multi Sensor, Photoelectric and Heat

$69.49

Ships in 10 business days
In Stock
Join FireAlarm Plus to reduce your cost per unit and gain faster access to inventory on this purchase.

Description

The Simplex 4098-9754 TrueAlarm Multi-Sensor is an intelligent addressable detector that combines photoelectric smoke detection and thermal heat sensing in a single device. The sensor communicates analog detection data to the fire alarm control panel, where alarm decisions, sensitivity settings, and environmental compensation are processed. This multi-sensor design improves fire detection reliability by evaluating smoke and temperature conditions simultaneously, helping reduce nuisance alarms while maintaining early detection capability. The detector communicates digitally over IDNet or MAPNET II signaling loops, allowing the control panel to continuously monitor sensor performance, sensitivity levels, and environmental conditions. When installed with compatible bases such as the 4098-9795 sounder base or 4098-9796 standard base, the device can provide additional functionality including local audible notification, remote alarm indication, or relay tracking. The sensor head supports 360° smoke entry, automatic sensitivity compensation, and programmable alarm thresholds configured at the fire alarm control panel. This model is typically used in commercial fire alarm systems where combined smoke and heat detection is preferred to improve detection accuracy and reduce false alarms.

Documents

Description

The Simplex 4098-9754 TrueAlarm Multi-Sensor is an intelligent addressable detector that combines photoelectric smoke detection and thermal heat sensing in a single device. The sensor communicates analog detection data to the fire alarm control panel, where alarm decisions, sensitivity settings, and environmental compensation are processed.

This multi-sensor design improves fire detection reliability by evaluating smoke and temperature conditions simultaneously, helping reduce nuisance alarms while maintaining early detection capability. The detector communicates digitally over IDNet or MAPNET II signaling loops, allowing the control panel to continuously monitor sensor performance, sensitivity levels, and environmental conditions.

When installed with compatible bases such as the 4098-9795 sounder base or 4098-9796 standard base, the device can provide additional functionality including local audible notification, remote alarm indication, or relay tracking. The sensor head supports 360° smoke entry, automatic sensitivity compensation, and programmable alarm thresholds configured at the fire alarm control panel.

This model is typically used in commercial fire alarm systems where combined smoke and heat detection is preferred to improve detection accuracy and reduce false alarms.

Additional information

Weight 0.4 lbs
Dimensions 2.25 × 4.875 × 4.875 in
Manufacturer

Johnson Controls

Brand

Simplex

Unit of Measurement

EA (Each)

Condition

New

Type

Detector

Style

Plug-In

Detection Method

Fixed Temperature, Photoelectric, Programmable, Rate-of-Rise

Detectable Medium

Heat, Smoke

Programming

Set via Base

Protocol

IDNet

Thermal Rating

135°F, 155°F, Programmable

Series

Production Status

Discontinued

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

Attributes

Additional information

Weight 0.4 lbs
Dimensions 2.25 × 4.875 × 4.875 in
Manufacturer

Johnson Controls

Brand

Simplex

Unit of Measurement

EA (Each)

Condition

New

Type

Detector

Style

Plug-In

Detection Method

Fixed Temperature, Photoelectric, Programmable, Rate-of-Rise

Detectable Medium

Heat, Smoke

Programming

Set via Base

Protocol

IDNet

Thermal Rating

135°F, 155°F, Programmable

Series

Production Status

Discontinued

Product Features

• Photoelectric smoke and thermal heat sensing in one detector
• Analog addressable communication via IDNet or MAPNET II
• Programmable smoke sensitivity at the control panel
• Fixed temperature and rate-of-rise heat detection options
• 360¬∞ smoke chamber for improved detection response
• LED status indicator for communication and alarm status
• Compatible with optional standard or sounder bases

What's Included

• 4098-9754 TrueAlarm Multi-Sensor detector head

Shipping Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1–5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock.

PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client. This product may be sourced from the manufacturer or supplier. If so, manufacturer cancellation fees may apply if the order is cancelled after processing. See our Terms of Sale for details.

Return Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee.

New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made.

Testimonials

Rick A.
Dallas, TXI
"Great service. I received help with exactly what I needed and I received it all in a timely manner."
Charles O.
New Brunswick, NJ
"I had a big engineering/logistics issue that William over at FireAlarm.com helped me with. I don’t know what I would’ve done without their help!"
Jason G.
Los Angeles, CA
"The fastest delivery I’ve seen. Needed overnight emergency parts and I got just that."
Julia S.
Tampa, FL
"Needed last-minute maintenance done on my building’s system, and FireAlarm.com exceeded my expectations with how quickly it was done."

Leave a review

Simplex 4098-9795
Mfr. Part #: 4098-9795
SKU: 64059
Limited Stock
Ships in 5 business days

$100.49

Pricing & Availability Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1 – 5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock. PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client.

Payment Details

You may remit payment via a US-Based Credit Card (CC Authorization Form), Wire Transfer (w/ $30 or $50 fee added to invoice), via PayPal (Or PayPal Pay Later), via Apple or Google Pay, or by mailing us a check. You can also call in with your credit card information at any time: 888-497-0290.

Return & Cancellation Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee. New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made. See our complete return policy for more information at: https://firealarm.com/faq/