Siemens FDO421 Addressable Photoelectric Smoke Detector

SKU: 37012
Manufacturer Part #: FDO421
Secondary Part #: S54320-F4-A1
Condition: New
Brand: Siemens
Status: Active

Photoelectric Smoke Detector, Built in Isolation

$172.49

Ships in 8 business days
Limited Stock
Join FireAlarm Plus to reduce your cost per unit and gain faster access to inventory on this purchase.

Description

The Siemens FDO421 is an intelligent, addressable photoelectric smoke detector designed for use with Desigo Fire Safety and FireFinder XLS/V series control panels. It incorporates microprocessor-based signal processing and an optical light-scattering sensing chamber to provide stable and accurate smoke detection.

The FDO421 features built-in ISOtechnology to support True Class-X SLC operation (optional use), enhancing loop reliability and enabling advanced addressable fault isolation (up to 252 isolation devices per SLC). The detector is polarity insensitive via SureWire technology and occupies one address on the signaling line circuit.

The unit includes automatic environmental compensation, extended temperature and humidity operating range, self-diagnostics performed every 10 seconds, and a tri-color 360° LED for status indication. The detector is UL 268 7th Edition listed and approved for direct in-air duct applications (UL 268A) where applicable.

Documents

Description

The Siemens FDO421 is an intelligent, addressable photoelectric smoke detector designed for use with Desigo Fire Safety and FireFinder XLS/V series control panels. It incorporates microprocessor-based signal processing and an optical light-scattering sensing chamber to provide stable and accurate smoke detection.

The FDO421 features built-in ISOtechnology to support True Class-X SLC operation (optional use), enhancing loop reliability and enabling advanced addressable fault isolation (up to 252 isolation devices per SLC). The detector is polarity insensitive via SureWire technology and occupies one address on the signaling line circuit.

The unit includes automatic environmental compensation, extended temperature and humidity operating range, self-diagnostics performed every 10 seconds, and a tri-color 360° LED for status indication. The detector is UL 268 7th Edition listed and approved for direct in-air duct applications (UL 268A) where applicable.

Additional information

Weight 0.32 lbs
Dimensions 4.13 × 4.13 × 1.93 in
Manufacturer

Siemens Industry, Inc.

Brand

Siemens

Condition

New

Unit of Measurement

EA (Each)

Production Status

Active

Type

Detector

Style

Plug-In

Detectable Medium

Smoke

Detection Method

Photoelectric

Programming

DPU

Voltage Range

16 – 30 VDC

Series

Compatibility

, , , , , , ,

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

Attributes

Additional information

Weight 0.32 lbs
Dimensions 4.13 × 4.13 × 1.93 in
Manufacturer

Siemens Industry, Inc.

Brand

Siemens

Condition

New

Unit of Measurement

EA (Each)

Production Status

Active

Type

Detector

Style

Plug-In

Detectable Medium

Smoke

Detection Method

Photoelectric

Programming

DPU

Voltage Range

16 – 30 VDC

Series

Compatibility

, , , , , , ,

Product Features

• Intelligent addressable photoelectric smoke detection
• UL 268 7th Edition Listed
• Built-in ISOtechnology (True Class-X SLC operation)
• Up to 252 isolation devices per SLC
• Polarity insensitive (SureWire technology)
• Self-testing and self-monitoring for sensitivity
• Complete diagnostics every 10 seconds
• Automatic environmental compensation
• Tri-color 360° status LED (Green / Yellow / Red)
• Extended temperature and humidity operating range
• Compatible with DB-11 series mounting bases
• Compatible with Model DPU programmer/test unit
• EMI and RFI immunity
• RoHS compliant

What's Included

• FDO421 Photoelectric Smoke Detector
• Protective Dust Cover

Shipping Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1–5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock.

PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client. This product may be sourced from the manufacturer or supplier. If so, manufacturer cancellation fees may apply if the order is cancelled after processing. See our Terms of Sale for details.

Return Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee.

New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made.

Testimonials

Rick A.
Dallas, TXI
"Great service. I received help with exactly what I needed and I received it all in a timely manner."
Charles O.
New Brunswick, NJ
"I had a big engineering/logistics issue that William over at FireAlarm.com helped me with. I don’t know what I would’ve done without their help!"
Jason G.
Los Angeles, CA
"The fastest delivery I’ve seen. Needed overnight emergency parts and I got just that."
Julia S.
Tampa, FL
"Needed last-minute maintenance done on my building’s system, and FireAlarm.com exceeded my expectations with how quickly it was done."

Leave a review

Siemens DB-11 Low Profile Detector Base
Mfr. Part #: DB-11
SKU: 4607
In Stock
Ships in 10 business days

$15.89

STI STI-9604
Mfr. Part #: STI-9604
SKU: 10907
In Stock
Ships in 3 business days

$31.49

Pricing & Availability Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1 – 5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock. PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client.

Payment Details

You may remit payment via a US-Based Credit Card (CC Authorization Form), Wire Transfer (w/ $30 or $50 fee added to invoice), via PayPal (Or PayPal Pay Later), via Apple or Google Pay, or by mailing us a check. You can also call in with your credit card information at any time: 888-497-0290.

Return & Cancellation Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee. New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made. See our complete return policy for more information at: https://firealarm.com/faq/