Description

The Simplex 4098-9756 is a TrueAlarm addressable duct smoke sensor housing designed to detect smoke within HVAC duct systems. It includes a factory-installed 4098-9714 TrueAlarm photoelectric smoke sensor and communicates with the fire alarm control panel via IDNet or MAPNET II communications.

This model provides a supervised relay control output for multiple remote relays and requires a separate 24 VDC fire alarm power source. One 4098-9843 remote relay is included. Relay operation is under panel control and may be activated manually or automatically in response to alarm or other programmed inputs.

The housing features a clear cover for visual inspection, magnetic test capability, diagnostic LEDs, and field-installable sampling tubes (ordered separately) to accommodate various duct widths. It is UL listed to Standard 268A for duct smoke detection applications.

Documents

Description

The Simplex 4098-9756 is a TrueAlarm addressable duct smoke sensor housing designed to detect smoke within HVAC duct systems. It includes a factory-installed 4098-9714 TrueAlarm photoelectric smoke sensor and communicates with the fire alarm control panel via IDNet or MAPNET II communications.

This model provides a supervised relay control output for multiple remote relays and requires a separate 24 VDC fire alarm power source. One 4098-9843 remote relay is included. Relay operation is under panel control and may be activated manually or automatically in response to alarm or other programmed inputs.

The housing features a clear cover for visual inspection, magnetic test capability, diagnostic LEDs, and field-installable sampling tubes (ordered separately) to accommodate various duct widths. It is UL listed to Standard 268A for duct smoke detection applications.

Additional information

Weight 2.5 lbs
Dimensions 3.375 × 6.75 × 11.375 in
Manufacturer

Johnson Controls

Brand

Simplex

Condition

New

Unit of Measurement

EA (Each)

Production Status

Active

Type

Duct Detector

Connection

Terminal Block

Construction

ABS, Polycarbonate

Detectable Medium

Smoke

Detection Method

Photoelectric

Location

Indoor, Outdoor*

Programming

DIP Switch

Protocol

IDNet, MAPNET II

Status Indicator

LED

Test Method

Magnet

Voltage

24 VDC

Voltage Range

18 – 32 VDC

Series

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

Attributes

Additional information

Weight 2.5 lbs
Dimensions 3.375 × 6.75 × 11.375 in
Manufacturer

Johnson Controls

Brand

Simplex

Condition

New

Unit of Measurement

EA (Each)

Production Status

Active

Type

Duct Detector

Connection

Terminal Block

Construction

ABS, Polycarbonate

Detectable Medium

Smoke

Detection Method

Photoelectric

Location

Indoor, Outdoor*

Programming

DIP Switch

Protocol

IDNet, MAPNET II

Status Indicator

LED

Test Method

Magnet

Voltage

24 VDC

Voltage Range

18 – 32 VDC

Series

Product Features

• Addressable duct smoke sensor housing with factory-installed photoelectric sensor
• IDNet or MAPNET II digital communication (auto-select)
• Supervised relay output for up to 15 total 4098-9843 relays
• Includes one 4098-9843 Form C relay
• Requires separate fused 24 VDC fire alarm power
• Clear cover for visual inspection
• Magnetic test feature for alarm initiation
• Test ports for airflow measurement and aerosol injection
• Diagnostic LEDs (Red status; Yellow relay supervision trouble indicator)
• Mounts to rectangular or round ducts (minimum 8 in square or 18 in round)
• UL 268A listed for duct applications

What's Included

• 4098-9756 Duct Sensor Housing
• Factory-installed 4098-9714 Photoelectric Sensor
• One 4098-9843 Remote Relay
• Exhaust Tube
• Gaskets
• Clear Cover

Shipping Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1–5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock.

PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client. This product may be sourced from the manufacturer or supplier. If so, manufacturer cancellation fees may apply if the order is cancelled after processing. See our Terms of Sale for details.

Return Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee.

New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made.

Testimonials

Rick A.
Dallas, TXI
"Great service. I received help with exactly what I needed and I received it all in a timely manner."
Charles O.
New Brunswick, NJ
"I had a big engineering/logistics issue that William over at FireAlarm.com helped me with. I don’t know what I would’ve done without their help!"
Jason G.
Los Angeles, CA
"The fastest delivery I’ve seen. Needed overnight emergency parts and I got just that."
Julia S.
Tampa, FL
"Needed last-minute maintenance done on my building’s system, and FireAlarm.com exceeded my expectations with how quickly it was done."

Leave a review

Simplex 2098-9806 Stainless Steel Remote Test Station
Mfr. Part #: 2098-9806
SKU: 37998
In Stock
Ships in 5 business days

$38.49

Simplex 4098-9856 49 Inch Plastic Sampling Tube
Mfr. Part #: 4098-9856
SKU: 72420
In Stock
Ships in 8 business days

$23.39

Simplex 4098-9854 Sampling Tube, 13", PVC Plastic
Mfr. Part #: 4098-9854
SKU: 72425
In Stock
Ships in 8 business days

$8.79

Simplex 4098-9855 24" Sampling Tube, Plastic
Mfr. Part #: 4098-9855
SKU: 72416
Limited Stock
Ships in 8 business days

$11.29

Pricing & Availability Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1 – 5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock. PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client.

Payment Details

You may remit payment via a US-Based Credit Card (CC Authorization Form), Wire Transfer (w/ $30 or $50 fee added to invoice), via PayPal (Or PayPal Pay Later), via Apple or Google Pay, or by mailing us a check. You can also call in with your credit card information at any time: 888-497-0290.

Return & Cancellation Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee. New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made. See our complete return policy for more information at: https://firealarm.com/faq/