This product has been replaced by

Wheelock SP4-LOC-SB

Local Operator Console and Remote Microphone

Manufacturer Part #: SP4-LOC-SB

Wheelock SP4-LOC-SB

Local Operator Console and Remote Microphone

Availability: Please Call for Availability
Condition: New
Brand: Wheelock
Status: Active
SKU: 79232
Manufacturer Part #: SP4-LOC-SB

Description

The SP4-LOC Remote Microphone and Local Operator Console is designed for indoor use with the SafePath4 SP40/2 and the SP40S panels for mass notification applications.

The SP4-LOC contains the SafePath4 SPRM Remote Microphone module and eight black push on/push off buttons which provide a contact closure used to activate the SP40/2 or SP40S digital messages in the ON position. The buttons change color from black in the OFF position to green in the ON position. A message name plate holder is located above the pushbuttons.

An optional HVAC Emergency Shutoff red, mushroom type cutoff pushbutton and labeling is available as a seperate kit.

The Remote Microphone module (SPRM) incorpoates a PushTo-Talk (PTT) microphone and system status LED indicators. The SPRM provides a microphone override for any tone generation, digitak voice module prerecorded message, background music, or telephone paging. It is equipped with a keyed lock that, when activated, allows the use of the module. The SPRM is fully supervised from the SP40/2 or the SP40S panel and contains front panel LEDs for remote indications of System Normal, System Trouble, and Alarm conditions. Voice frequency response shall be 275 Hz-6.5 kHz +/- 2.4 dB. Power requirements shall be 24VDC and will be supplied by the SP40/2 or SP40S. Input current for standby mode shall be 26mA and 38mA in the alarm mode. Shielded 6-wire cable shall be used. Approvals for the system shall include; UL Standard 864, UL Standard 1711, FCC Part 15, and CSFM. The panel shall be OSHA 1910.165 and ADA compliant.

Documents

Description

The SP4-LOC Remote Microphone and Local Operator Console is designed for indoor use with the SafePath4 SP40/2 and the SP40S panels for mass notification applications.

The SP4-LOC contains the SafePath4 SPRM Remote Microphone module and eight black push on/push off buttons which provide a contact closure used to activate the SP40/2 or SP40S digital messages in the ON position. The buttons change color from black in the OFF position to green in the ON position. A message name plate holder is located above the pushbuttons.

An optional HVAC Emergency Shutoff red, mushroom type cutoff pushbutton and labeling is available as a seperate kit.

The Remote Microphone module (SPRM) incorpoates a PushTo-Talk (PTT) microphone and system status LED indicators. The SPRM provides a microphone override for any tone generation, digitak voice module prerecorded message, background music, or telephone paging. It is equipped with a keyed lock that, when activated, allows the use of the module. The SPRM is fully supervised from the SP40/2 or the SP40S panel and contains front panel LEDs for remote indications of System Normal, System Trouble, and Alarm conditions. Voice frequency response shall be 275 Hz-6.5 kHz +/- 2.4 dB. Power requirements shall be 24VDC and will be supplied by the SP40/2 or SP40S. Input current for standby mode shall be 26mA and 38mA in the alarm mode. Shielded 6-wire cable shall be used. Approvals for the system shall include; UL Standard 864, UL Standard 1711, FCC Part 15, and CSFM. The panel shall be OSHA 1910.165 and ADA compliant.

Additional information

Weight 8 lbs
Dimensions 16.25 × 15.50 × 3.50 in
Brand

Manufacturer

Eaton Corporation

Condition

New

Production Status

Active

Reviews

There are no reviews yet.

Be the first to review “Wheelock SP4-LOC-SB”

SP4-LOC Remote Microphone and Local Operator Console

Download

Cooper - Data Sheet

REMOTE MICROPHONE AND LOCAL OPERATING CONSOLE

Download

Cooper - Installation Instructions

Attributes

Weight 8 lbs
Dimensions 16.25 × 15.50 × 3.50 in
Brand

Manufacturer

Eaton Corporation

Condition

New

Production Status

Active

Product Features

What's Included

Shipping Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1 – 5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock. PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client.

Return Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee. New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made. See our complete return policy for more information at: https://firealarm.com/faq/

Testimonials

Rick A.
Dallas, TXI
Read More
"Great service. I received help with exactly what I needed and I received it all in a timely manner."
Charles O.
New Brunswick, NJ
Read More
"I had a big engineering/logistics issue that William over at FireAlarm.com helped me with. I don’t know what I would’ve done without their help!"
Jason G.
Los Angeles, CA
Read More
"The fastest delivery I’ve seen. Needed overnight emergency parts and I got just that."
Julia S.
Tampa, FL
Read More
"Needed last-minute maintenance done on my building’s system, and FireAlarm.com exceeded my expectations with how quickly it was done."

Leave a review

Reviews

There are no reviews yet.

Be the first to review “Wheelock SP4-LOC-SB”

You may also like...

Pricing & Availability Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1 – 5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock. PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client.

Payment Details

You may remit payment via a US-Based Credit Card (CC Authorization Form), Wire Transfer (w/ $30 or $50 fee added to invoice), via PayPal (Or PayPal Pay Later), via Apple or Google Pay, or by mailing us a check. You can also call in with your credit card information at any time: 888-497-0290.

Return & Cancellation Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee. New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made. See our complete return policy for more information at: https://firealarm.com/faq/