This product has been replaced by

Fire-Lite ECC-RPU

Remote Page Unit

Manufacturer Part #: ECC-RPU

Fire-Lite ECC-RPU

$1,234.60

Remote Page Unit

Availability: In Stock
Condition: New
Brand: Fire-Lite
Status: Active
SKU: 30287
Manufacturer Part #: ECC-RPU

Description

The ECC-RPU is an optional Remote Page Unit that is com- patible with the ECC-50/100(E) Emergency Command Center for fire protection applications. It is part of the family of external remote consoles that allows for extending the ECC-50/100(E) display and control to remote locations within a building. It is housed in a cabinet with a keyed or an optional thumb lock to limit access to qualified personnel. The ECC-RPU includes a built-in microphone and 8 selection buttons that can be pushed to activate the system remotely. ALL CALL paging can be broadcast over the speaker circuits by depressing the microphone's push-to talk button. As an added benefit, the 9th button on the RPU can be used to acti- vate an MMF-300 monitor module that may be installed inside the ECC-RPU cabinet to be used for applications such as HVAC shutdown. The ECC-RPU requires an external data bus connection, an external audio riser connection, and an exter- nal operator interface power connection (24 Volts DC) from the ECC-50/100 main console.

Documents

Description

The ECC-RPU is an optional Remote Page Unit that is com- patible with the ECC-50/100(E) Emergency Command Center for fire protection applications. It is part of the family of external remote consoles that allows for extending the ECC-50/100(E) display and control to remote locations within a building. It is housed in a cabinet with a keyed or an optional thumb lock to limit access to qualified personnel.

The ECC-RPU includes a built-in microphone and 8 selection buttons that can be pushed to activate the system remotely. ALL CALL paging can be broadcast over the speaker circuits by depressing the microphone’s push-to talk button. As an added benefit, the 9th button on the RPU can be used to acti- vate an MMF-300 monitor module that may be installed inside the ECC-RPU cabinet to be used for applications such as HVAC shutdown. The ECC-RPU requires an external data bus connection, an external audio riser connection, and an exter- nal operator interface power connection (24 Volts DC) from the ECC-50/100 main console.

Additional information

Weight 1 lbs
Manufacturer

Honeywell

Condition

New

Brand

Production Status

Active

Reviews

There are no reviews yet.

Be the first to review “Fire-Lite ECC-RPU”

Emergency Command Center

Download

Fire-Lite Alarms - Data Sheet

ECC-RPU Remote Page Unit

Download

Fire-Lite - Data Sheet

Attributes

Weight 1 lbs
Manufacturer

Honeywell

Condition

New

Brand

Production Status

Active

Product Features

  • Provides messaging status and control of the ECC-50/ 100(E) primary operator console.
  • Modular design for maximum system flexibility and easy expansion.
  • Supports both Class A (Style Z) and Class B (Style Y) wir- ing.
  • A maximum of eight ECC-RPU’s can be connected to an ECC-50/100(E) primary operating console.
  • Built-in microphone with push-to-talk feature that can be used for ALL CALL paging.
  • Up to fourteen programmable messaging functions that can be activated over speaker zones remotely.
  • Sturdy cabinet design with a keyed lock to prevent unautho- rized access. Optional thumb lock available.
  • Simple and straightforward user interface.
  • Additional 9th button can be used to activate an optional MMF-300 monitor module installed inside the cabinet for applications such as HVAC shutdown.

What's Included

Shipping Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1 – 5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock. PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client.

Return Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee. New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made. See our complete return policy for more information at: https://firealarm.com/faq/

Testimonials

Rick A.
Dallas, TXI
Read More
"Great service. I received help with exactly what I needed and I received it all in a timely manner."
Charles O.
New Brunswick, NJ
Read More
"I had a big engineering/logistics issue that William over at FireAlarm.com helped me with. I don’t know what I would’ve done without their help!"
Jason G.
Los Angeles, CA
Read More
"The fastest delivery I’ve seen. Needed overnight emergency parts and I got just that."
Julia S.
Tampa, FL
Read More
"Needed last-minute maintenance done on my building’s system, and FireAlarm.com exceeded my expectations with how quickly it was done."

Leave a review

Reviews

There are no reviews yet.

Be the first to review “Fire-Lite ECC-RPU”

You may also like...

Pricing & Availability Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1 – 5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock. PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client.

Payment Details

You may remit payment via a US-Based Credit Card (CC Authorization Form), Wire Transfer (w/ $30 or $50 fee added to invoice), via PayPal (Or PayPal Pay Later), via Apple or Google Pay, or by mailing us a check. You can also call in with your credit card information at any time: 888-497-0290.

Return & Cancellation Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee. New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made. See our complete return policy for more information at: https://firealarm.com/faq/