Vesda PIP-024

$63.82

Non-return valve for pipework

Availability: Estimated 30 days
Condition: New
Brand: Vesda
Status: Active
SKU: 45985
Manufacturer Part #: PIP-024

Description

ASD systems continuously monitor the air in the protected environment, potentially subjecting the system to contamination over time. In order to prevent the build- up of dust and dirt on sampling holes and pipe network, regular pipe network purging with compressed air is essential. In contrast to conventional purging systems, the VSP-820 unit features a single built- in Solenoid valve, which initiates the release of air into the pipe network. This valve also increases the reliability of the system by protecting the unit from any compressed air damage and can be accessed through a control board integrated into the housing. Installation cost is greatly reduced, thanks to the unit’s compact design, which removes the need for additional mechanical and electrical control devices. Further cost savings are realized due to reduced cabling and commissioning requirements. User-definable purging processes and customizable program features allow the VSP-820 to deliver continuous and uninterrupted airflow whilst optimizing benchmark preventative maintenance regimes, through automatic purging processes settable at specific times. Designed with the engineer in mind, the unit offers additional flexibility through the use of an external push- button or central timer as an input to allow the initiation of additional manual or automatic activations of the purging process.

Documents

Description

ASD systems continuously monitor the air in the protected environment, potentially subjecting the system to contamination over time. In order to prevent the build- up of dust and dirt on sampling holes and pipe network, regular pipe network purging with compressed air is essential.

In contrast to conventional purging systems, the VSP-820 unit features a single built- in Solenoid valve, which initiates the release of air into the pipe network. This valve also increases the reliability of the system by protecting the unit from any compressed air damage and can be accessed through a control board integrated into the housing.

Installation cost is greatly reduced, thanks to the unit’s compact design, which removes the need for additional mechanical and electrical control devices. Further cost savings are realized due to reduced cabling and commissioning requirements.

User-definable purging processes and customizable program features allow the VSP-820 to deliver continuous and uninterrupted airflow whilst optimizing benchmark preventative maintenance regimes, through automatic purging processes settable at specific times.

Designed with the engineer in mind, the unit offers additional flexibility through the use of an external push- button or central timer as an input to allow the initiation of additional manual or automatic activations of the purging process.

Additional information

Weight 1 lbs
Manufacturer

Honeywell International

Brand

Condition

New

Unit of Measurement

EA (Each)

Series

Production Status

Active

Reviews

There are no reviews yet.

Be the first to review “Vesda PIP-024”

VESDA Automatic Purging Unit Data Sheet

Download

Vesda - Data Sheet

Attributes

Weight 1 lbs
Manufacturer

Honeywell International

Brand

Condition

New

Unit of Measurement

EA (Each)

Series

Production Status

Active

Product Features

  • A user-friendly and compact system, designed for larger pipe networks
  • Compatible with VESDA, ICAM and FAAST Aspiration Smoke Detection (ASD) systems
  • Patented design without air resistance (as defined by EN 54-20)
  • 6 user selectable preventative or event- triggered purging programs – short or long purging cycle options
  • Internal clock or external clock timer can be connected
  • Several systems can be networked in Master-Slave mode
  • Manual control via an external push-button
  • Automatic initiation if a fault message is received from the ASD system (activating through FACP only)
  • Easy commissioning without software tools
  • Multicolored LED indicates system condition

What's Included

Shipping Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1 – 5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock. PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client.

Return Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee. New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made. See our complete return policy for more information at: https://firealarm.com/faq/

Testimonials

Rick A.
Dallas, TXI
Read More
"Great service. I received help with exactly what I needed and I received it all in a timely manner."
Charles O.
New Brunswick, NJ
Read More
"I had a big engineering/logistics issue that William over at FireAlarm.com helped me with. I don’t know what I would’ve done without their help!"
Jason G.
Los Angeles, CA
Read More
"The fastest delivery I’ve seen. Needed overnight emergency parts and I got just that."
Julia S.
Tampa, FL
Read More
"Needed last-minute maintenance done on my building’s system, and FireAlarm.com exceeded my expectations with how quickly it was done."

Leave a review

Reviews

There are no reviews yet.

Be the first to review “Vesda PIP-024”

Pricing & Availability Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1 – 5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock. PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client.

Payment Details

You may remit payment via a US-Based Credit Card (CC Authorization Form), Wire Transfer (w/ $30 or $50 fee added to invoice), via PayPal (Or PayPal Pay Later), via Apple or Google Pay, or by mailing us a check. You can also call in with your credit card information at any time: 888-497-0290.

Return & Cancellation Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee. New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made. See our complete return policy for more information at: https://firealarm.com/faq/