Notifier HS-NCM-MF

$2,151.42

High-Speed Network Communications Module, fiber-optic cable interface (multi-mode)

Availability: Please Call for Availability
Condition: New
Brand: Notifier
Status: Active
SKU: 48616
Manufacturer Part #: HS-NCM-MF

Description

The High-Speed Network Communications Module (HS-NCM) provides NOTIFIER’s NFS-320, NFS-640, NFS2-640, NFS-3030, and NFS2-3030 Fire Alarm Control Panels, NCA and NCA-2 Network Control Annunciators, and DVC Digital Voice Command with a means to connect to High-Speed NOTI•FIRE•NET (NFN).

Each HS-NCM can accommodate up to two node addresses. For example, one HS-NCM can provide network communication for both an NFS2-640 and an NCA-2.

When not connected to a fire alarm panel, the HS-NCM defaults to repeater mode and can be used to boost signal distances or to pass data transmissions between two differently configured network segments when wire and fiber co-exist on a network.

Documents

Description

The High-Speed Network Communications Module (HS-NCM) provides NOTIFIER’s NFS-320, NFS-640, NFS2-640, NFS-3030, and NFS2-3030 Fire Alarm Control Panels, NCA and NCA-2 Network Control Annunciators, and DVC Digital Voice Command with a means to connect to High-Speed NOTI•FIRE•NET (NFN).

Each HS-NCM can accommodate up to two node addresses. For example, one HS-NCM can provide network communication for both an NFS2-640 and an NCA-2.

When not connected to a fire alarm panel, the HS-NCM defaults to repeater mode and can be used to boost signal distances or to pass data transmissions between two differently configured network segments when wire and fiber co-exist on a network.

Additional information

Weight 1 lbs
Series

Manufacturer

Honeywell International

Unit of Measurement

EA (Each)

Condition

New

Compatibility

N16e, N16x, NFS-320, NFS2-3030, NFS2-640

Brand

Production Status

Active

Listings & Approvals

CSFM, FM, NYC, UL, ULC

Reviews

There are no reviews yet.

Be the first to review “Notifier HS-NCM-MF”

HS-NCM High-Speed Network Communications Modules

Download

Notifier - Data Sheet

Product Installation Document: High-Speed Network Communications Module

Download

Notifier - Installation Sheet

Network System Interface

Download

Notifier - Instruction Manual

Attributes

Weight 1 lbs
Series

Manufacturer

Honeywell International

Unit of Measurement

EA (Each)

Condition

New

Compatibility

N16e, N16x, NFS-320, NFS2-3030, NFS2-640

Brand

Production Status

Active

Listings & Approvals

CSFM, FM, NYC, UL, ULC

Product Features

  • Supports fiber-optic medium
  • NFPA Style 4 (Class B) or Style 7 (Class A) operation
  • Data is immune to all environmental noise
  • Optical isolation prevents ground loops
  • High-Speed NFN fiber-optic medium
  • Fiber type: 62.5/125 micrometers (multi-mode); 50/125 micrometers (multimode), or 9/125 micrometers (single mode)
  • Maximum attenuation: 10 dB with 62.5/125 μm cable, 6.5 dB with 50/125 μm cable, and 30 dB with 9/125 μm cable
  • Wavelength (1): 1310 nanometers
  • Connectors: LC style
  • Baud transmission rate: 100 Mb
  • Data is regenerated at each node
  • Two network ports to allow simultaneous connection to fire alarm control panel and to programming computer
  • Enables software and database upload/download over the High-Speed NFN

What's Included

Shipping Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1 – 5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock. PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client.

Return Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee. New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made. See our complete return policy for more information at: https://firealarm.com/faq/

Testimonials

Rick A.
Dallas, TXI
Read More
"Great service. I received help with exactly what I needed and I received it all in a timely manner."
Charles O.
New Brunswick, NJ
Read More
"I had a big engineering/logistics issue that William over at FireAlarm.com helped me with. I don’t know what I would’ve done without their help!"
Jason G.
Los Angeles, CA
Read More
"The fastest delivery I’ve seen. Needed overnight emergency parts and I got just that."
Julia S.
Tampa, FL
Read More
"Needed last-minute maintenance done on my building’s system, and FireAlarm.com exceeded my expectations with how quickly it was done."

Leave a review

Reviews

There are no reviews yet.

Be the first to review “Notifier HS-NCM-MF”

Pricing & Availability Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1 – 5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock. PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client.

Payment Details

You may remit payment via a US-Based Credit Card (CC Authorization Form), Wire Transfer (w/ $30 or $50 fee added to invoice), via PayPal (Or PayPal Pay Later), via Apple or Google Pay, or by mailing us a check. You can also call in with your credit card information at any time: 888-497-0290.

Return & Cancellation Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee. New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made. See our complete return policy for more information at: https://firealarm.com/faq/