Mini Monitor Module, Dry Contact

$118.49

Ships in 8 business days
Limited Stock
Join FireAlarm Plus to reduce your cost per unit and gain faster access to inventory on this purchase.

Description

The Mircom MIX-M501MAP is a miniature addressable monitor module designed to interface dry-contact initiating devices with Mircom intelligent fire alarm control panels. It supervises a Style B (Class B) initiating circuit and reports status conditions such as normal, open, or alarm to the fire alarm control panel through the signaling line circuit (SLC).

The compact design allows the module to be installed inside electrical boxes or mounted behind initiating devices such as manual pull stations, waterflow switches, or conventional detectors. This makes it particularly useful in retrofit installations or applications where space is limited.

The module uses Mircom’s Advanced Protocol (AP) communication technology, which provides faster communication between field devices and the control panel. The AP protocol allows devices to operate using a grouped polling method with interrupt capability, increasing response speed and supporting larger system capacity. The module can also operate in CLIP mode for compatibility with legacy systems.

Documents

Description

The Mircom MIX-M501MAP is a miniature addressable monitor module designed to interface dry-contact initiating devices with Mircom intelligent fire alarm control panels. It supervises a Style B (Class B) initiating circuit and reports status conditions such as normal, open, or alarm to the fire alarm control panel through the signaling line circuit (SLC).

The compact design allows the module to be installed inside electrical boxes or mounted behind initiating devices such as manual pull stations, waterflow switches, or conventional detectors. This makes it particularly useful in retrofit installations or applications where space is limited.

The module uses Mircom’s Advanced Protocol (AP) communication technology, which provides faster communication between field devices and the control panel. The AP protocol allows devices to operate using a grouped polling method with interrupt capability, increasing response speed and supporting larger system capacity. The module can also operate in CLIP mode for compatibility with legacy systems.

Additional information

Weight 0.5 lbs
Dimensions 1.30 × 2.75 × 0.65 in
Manufacturer

Mircom Technologies Ltd.

Brand

Mircom

Programming

Rotary Dials

Unit of Measurement

EA (Each)

Terminal Type

Wire Leads

Series

Condition

New

Production Status

Active

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

Attributes

Additional information

Weight 0.5 lbs
Dimensions 1.30 × 2.75 × 0.65 in
Manufacturer

Mircom Technologies Ltd.

Brand

Mircom

Programming

Rotary Dials

Unit of Measurement

EA (Each)

Terminal Type

Wire Leads

Series

Condition

New

Production Status

Active

Product Features

• Miniature addressable monitor module for dry-contact devices
• Supervises a Style B (Class B) initiating circuit
• Compact size allows installation inside junction boxes or behind devices
• Interfaces manual stations, waterflow switches, and other contact devices
• Advanced Protocol communication increases response speed
• Backwards compatible with CLIP communication mode
• Rotary switches allow simple device addressing
• Low standby current for efficient loop operation
• Designed for use in intelligent two-wire fire alarm systems

What's Included

• MIX-M501MAP mini monitor module

Shipping Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1–5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock.

PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client. This product may be sourced from the manufacturer or supplier. If so, manufacturer cancellation fees may apply if the order is cancelled after processing. See our Terms of Sale for details.

Return Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee.

New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made.

Testimonials

Rick A.
Dallas, TXI
"Great service. I received help with exactly what I needed and I received it all in a timely manner."
Charles O.
New Brunswick, NJ
"I had a big engineering/logistics issue that William over at FireAlarm.com helped me with. I don’t know what I would’ve done without their help!"
Jason G.
Los Angeles, CA
"The fastest delivery I’ve seen. Needed overnight emergency parts and I got just that."
Julia S.
Tampa, FL
"Needed last-minute maintenance done on my building’s system, and FireAlarm.com exceeded my expectations with how quickly it was done."

Leave a review

Pricing & Availability Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1 – 5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock. PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client.

Payment Details

You may remit payment via a US-Based Credit Card (CC Authorization Form), Wire Transfer (w/ $30 or $50 fee added to invoice), via PayPal (Or PayPal Pay Later), via Apple or Google Pay, or by mailing us a check. You can also call in with your credit card information at any time: 888-497-0290.

Return & Cancellation Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee. New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made. See our complete return policy for more information at: https://firealarm.com/faq/