Mircom RB-MR-2200

Replacement Board for MR-2200

Availability: Please call for availability
Condition: New
Brand: Mircom
Status: Active
SKU: 71809
Manufacturer Part #: RB-MR-2200

Description

The MR-2100/MR-2200 Fire Alarm Control Panel (FACP) is the heart of a sophisticated microprocessor based fire detection system. Meeting the demands of economy and capability, these modular panel offer support for one or two loops of up to 198 devices on each loop. Optional modules mount directly to the chassis. Modules are available that provide additional NAC output circuits, function relay output circuits, annunciation, etc. This modular approach to system design virtually guarantees that as your needs -- and applicable local codes -- evolve, your FACP can change along with them. Networking can be utilized to provide additional input circuits, visual zones, bell circuits and relays. Up to 254 units (FACPs and/or annunciators) can be connected to form the Class A Style 7 (DCLR) network loop. Networking is limited to two nodes for ULC applications. Programming the MR-2100/MR-2200 has two components: Input circuit programming and special features, such as day/night mode, et cetera, are done from an externally generated database produced on a Windows based PC, while system parameters are programmed from the LCD and keypad.

Documents

Description

The MR-2100/MR-2200 Fire Alarm Control Panel (FACP) is the heart of a sophisticated microprocessor based fire detection system. Meeting the demands of economy and capability, these modular panel offer support for one or two loops of up to 198 devices on each loop. Optional modules mount directly to the chassis. Modules are available that provide additional NAC output circuits, function relay output circuits, annunciation, etc. This modular approach to system design virtually guarantees that as your needs — and applicable local codes — evolve, your FACP can change along with them.

Networking can be utilized to provide additional input circuits, visual zones, bell circuits and relays. Up to 254 units (FACPs and/or annunciators) can be connected to form the Class A Style 7 (DCLR) network loop. Networking is limited to two nodes for ULC applications. Programming the MR-2100/MR-2200 has two components: Input circuit programming and special features, such as day/night mode, et cetera, are done from an externally generated database produced on a Windows based PC, while system parameters are programmed from the LCD and keypad.

Additional information

Weight 15 lbs
Brand

Condition

New

Production Status

Active

Reviews

There are no reviews yet.

Be the first to review “Mircom RB-MR-2200”

Attributes

Weight 15 lbs
Brand

Condition

New

Production Status

Active

Product Features

  • MR-2200: Two (2) Addressable Input (SLC) circuits, Class A (Style 6) or Class B (Style 4).
  • Two (2) Notification Appliance Circuits (NAC), Class A (Style Z) or Class B (Style Y). Expandable to eight (8) NAC with optional module MRNC2 (groups of 2).
  • Four (4) Programmable function relays, Form C. Expandable to sixteen (16) relays with optional module MRRL4 (groups of 4).
  • Two (2) Auxiliary power outputs.
  • Optional peer-to-peer networking with existing Secutron MR network.
  • Total 24V Power Supply: 2.6A, expandable to 8.2A.
  • Integral battery charger.
  • LCD/LED system status display, with optional LED zone display.
  • Surface/flush mount cabinet with dead-front construction, capable of holding two 12Ah batteries with removable door for easy installation.
  • Removable terminal blocks for easy wiring.
  • Operating program and database can both be uploaded/downloaded by PC.

What's Included

Shipping Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1 – 5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock. PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client.

Return Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee. New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made. See our complete return policy for more information at: https://firealarm.com/faq/

Testimonials

Rick A.
Dallas, TXI
Read More
"Great service. I received help with exactly what I needed and I received it all in a timely manner."
Charles O.
New Brunswick, NJ
Read More
"I had a big engineering/logistics issue that William over at FireAlarm.com helped me with. I don’t know what I would’ve done without their help!"
Jason G.
Los Angeles, CA
Read More
"The fastest delivery I’ve seen. Needed overnight emergency parts and I got just that."
Julia S.
Tampa, FL
Read More
"Needed last-minute maintenance done on my building’s system, and FireAlarm.com exceeded my expectations with how quickly it was done."

Leave a review

Reviews

There are no reviews yet.

Be the first to review “Mircom RB-MR-2200”

Pricing & Availability Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1 – 5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock. PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client.

Payment Details

You may remit payment via a US-Based Credit Card (CC Authorization Form), Wire Transfer (w/ $30 or $50 fee added to invoice), via PayPal (Or PayPal Pay Later), via Apple or Google Pay, or by mailing us a check. You can also call in with your credit card information at any time: 888-497-0290.

Return & Cancellation Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee. New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made. See our complete return policy for more information at: https://firealarm.com/faq/