Air Products & Controls HS-100-N

$143.28

Plenum Smoke Detection 230VAC 115VAC 24VAC/24 UL

Availability: Estimated 10 days
Condition: New
Brand: Air Products & Controls
Status: Active
SKU: 183676
Manufacturer Part #: HS-100-N

Description

The HS-100 Special Application Photoelectric Duct Smoke Detector is designed specifically for installations where standard external mount duct detectors cannot be utilized. Application examples include HVAC plenum return systems in commercial rooftop package units, air shafts, between-ceiling plenum spaces, dampers and Applications requiring extremely low or no air velocity (≤ 100 ft./min).

Documents

Description

The HS-100 Special Application Photoelectric Duct Smoke Detector is designed specifically for installations where standard external mount duct detectors cannot be utilized. Application examples include HVAC plenum return systems in commercial rooftop package units, air shafts, between-ceiling plenum spaces, dampers and Applications requiring extremely low or no air velocity (≤ 100 ft./min).

Additional information

Weight 1.00 lbs
Dimensions 6.00 × 6.00 × 4.00 in
Manufacturer

Apollo Fire Detectors

Brand

Condition

New

Unit of Measurement

EA (Each)

Production Status

Active

Listings & Approvals

MEA, UL

Reviews

There are no reviews yet.

Be the first to review “Air Products & Controls HS-100-N”

HS-100 Data Sheet

Download

Air Products and Controls - Data Sheet

HS-100 Installation

Download

Air Products and Controls - Installation Guide

Attributes

Weight 1.00 lbs
Dimensions 6.00 × 6.00 × 4.00 in
Manufacturer

Apollo Fire Detectors

Brand

Condition

New

Unit of Measurement

EA (Each)

Production Status

Active

Listings & Approvals

MEA, UL

Product Features

  • No- and Low-Flow Technology: Photoelectric listed for air velocity from 0 – 3,000 feet/min
  • Listed for high-temperature Applications
  • Operating voltages: 230VAC, 115VAC, 24VAC, 24VDC
  • Interconnect up to 30 units for common functions
  • Compatible for interconnection and operation with Air Products’ SL-2000, RT-3000 and SM-501 Series Duct Smoke Detectors, MSR Series Remote
  • Accessories and MS Series Remote Accessories
  • Accessible, discrete terminal blocks for easier wiring v Flashing LED on detector head indicates normal operation
  • Magnet test capability (magnet included)
  • More wiring space than competitive models
  • Unit includes red alarm visual indicator
  • CSFM Listing and MEA Acceptance
  • Compact, lightweight size means easy handling, lower
  • One set of 10A form “C” alarm contacts
  • One set of 2A form “A” alarm contacts
  • One set of 10A form “C” trouble contacts
  • Large terminal connection screws
  • Advanced detector head design yields internal dust filtering
  • Compatible with building automation and fire alarm systems
  • Complete wiring details permanently attached to unit v Standard 4″ square back box mounting allows surface or “pendant” configurations
  • Low profile design
  • Tamper-resistant feature

 

What's Included

Shipping Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1 – 5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock. PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client.

Return Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee. New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made. See our complete return policy for more information at: https://firealarm.com/faq/

Testimonials

Rick A.
Dallas, TXI
Read More
"Great service. I received help with exactly what I needed and I received it all in a timely manner."
Charles O.
New Brunswick, NJ
Read More
"I had a big engineering/logistics issue that William over at FireAlarm.com helped me with. I don’t know what I would’ve done without their help!"
Jason G.
Los Angeles, CA
Read More
"The fastest delivery I’ve seen. Needed overnight emergency parts and I got just that."
Julia S.
Tampa, FL
Read More
"Needed last-minute maintenance done on my building’s system, and FireAlarm.com exceeded my expectations with how quickly it was done."

Leave a review

Reviews

There are no reviews yet.

Be the first to review “Air Products & Controls HS-100-N”

Pricing & Availability Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1 – 5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock. PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client.

Payment Details

You may remit payment via a US-Based Credit Card (CC Authorization Form), Wire Transfer (w/ $30 or $50 fee added to invoice), via PayPal (Or PayPal Pay Later), via Apple or Google Pay, or by mailing us a check. You can also call in with your credit card information at any time: 888-497-0290.

Return & Cancellation Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee. New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made. See our complete return policy for more information at: https://firealarm.com/faq/