Altronix ACMS8K1

$202.11

Kit includes: VR6 Voltage Regulator and ACMS8 Dual input Access Power Controller

Availability: Estimated 12 days
Condition: New
Brand: Altronix
Status: Active
SKU: 17414
Manufacturer Part #: ACMS8K1

Description

Altronix VR6 Voltage Regulator converts a 24VDC input into a regulated 5VDC or 12VDC selectable output at up to 6A supply current. It reduces the cost of adding an additional power supply to achieve 24VDC and 12VDC or 5VDC simultaneously, saving valuable enclosure space. Altronix ACMS8 dual input design allows power to be steered from two (2) independent low voltage 12 or 24 VDC power sources into eight (8) independently controlled fuse protected outputs. In ACMS8, these power outputs can also be converted to dry form “C” contacts. Outputs are activated by an open collector sink, normally open (NO) or normally closed (NC) dry trigger input from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc. ACMS8 will route power to a variety of access control hardware devices including Mag Locks, Electric Strikes, Magnetic Door Holders, etc. Outputs will operate in both Fail-Safe and/or Fail-Secure modes. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the eight (8) outputs. The spade connectors allow you to daisy chain power to multiple ACMS8 modules. This feature allows you to distribute the power over more outputs for larger systems.

Documents

Description

Altronix VR6 Voltage Regulator converts a 24VDC input into a regulated 5VDC or 12VDC selectable output at up to 6A supply current. It reduces the cost of adding an additional power supply to achieve 24VDC and 12VDC or 5VDC simultaneously, saving valuable enclosure space. Altronix ACMS8 dual input design allows power to be steered from two (2) independent low voltage 12 or 24 VDC power sources into eight (8) independently controlled fuse protected outputs. In ACMS8, these power outputs can also be converted to dry form “C” contacts. Outputs are activated by an open collector sink, normally open (NO) or normally closed (NC) dry trigger input from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc. ACMS8 will route power to a variety of access control hardware devices including Mag Locks, Electric Strikes, Magnetic Door Holders, etc. Outputs will operate in both Fail-Safe and/or Fail-Secure modes. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the eight (8) outputs. The spade connectors allow you to daisy chain power to multiple ACMS8 modules. This feature allows you to distribute the power over more outputs for larger systems.

Additional information

Weight 1.45 lbs
Dimensions 4.13 × 7.65 × 1.25 in
Manufacturer

Altronix Corp.

Brand

Condition

New

Unit of Measurement

EA (Each)

Production Status

Active

Reviews

There are no reviews yet.

Be the first to review “Altronix ACMS8K1”

Voltage Regulator; VR6

Download

Altronix - Data Sheet

Voltage Regulator; VR6

Download

Altronix - Installation Manual

Multi-Output Access Power Controllers; ACMS8 and ACMS8CB

Download

Altronix - Data Sheet

UL Listed Sub-Assembly Access Power Controllers; ACMS8 Series

Download

Altronix - Installation Manual

Attributes

Weight 1.45 lbs
Dimensions 4.13 × 7.65 × 1.25 in
Manufacturer

Altronix Corp.

Brand

Condition

New

Unit of Measurement

EA (Each)

Production Status

Active

Product Features

What's Included

Shipping Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1 – 5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock. PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client.

Return Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee. New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made. See our complete return policy for more information at: https://firealarm.com/faq/

Testimonials

Rick A.
Dallas, TXI
Read More
"Great service. I received help with exactly what I needed and I received it all in a timely manner."
Charles O.
New Brunswick, NJ
Read More
"I had a big engineering/logistics issue that William over at FireAlarm.com helped me with. I don’t know what I would’ve done without their help!"
Jason G.
Los Angeles, CA
Read More
"The fastest delivery I’ve seen. Needed overnight emergency parts and I got just that."
Julia S.
Tampa, FL
Read More
"Needed last-minute maintenance done on my building’s system, and FireAlarm.com exceeded my expectations with how quickly it was done."

Leave a review

Reviews

There are no reviews yet.

Be the first to review “Altronix ACMS8K1”

Pricing & Availability Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1 – 5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock. PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client.

Payment Details

You may remit payment via a US-Based Credit Card (CC Authorization Form), Wire Transfer (w/ $30 or $50 fee added to invoice), via PayPal (Or PayPal Pay Later), via Apple or Google Pay, or by mailing us a check. You can also call in with your credit card information at any time: 888-497-0290.

Return & Cancellation Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee. New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made. See our complete return policy for more information at: https://firealarm.com/faq/