This product has been replaced by

Det-Tronics EQ3750ASH (010210-002)

Eagle Quantum Premier ® Addressable Smoke & Heat (ASH) Module

Manufacturer Part #: EQ3750ASH

Det-Tronics EQ3750ASH (010210-002)

$3,971.11

Eagle Quantum Premier ® Addressable Smoke & Heat (ASH) Module

Availability: Please Call for Availability
Condition: New
Brand: Det-Tronics
Status: Active
SKU: 120996
Manufacturer Part #: EQ3750ASH
Secondary Part #: 010210-002

Description

The EQP Addressable Smoke and Heat (ASH) Module is designed to expand the input and output capability of the Det-Tronics Eagle Quantum Premier® system. The ASH is an interface device designed to provide continuous and automated fire protection. It ensures system operation through supervision of system inputs/outputs and Local Operating Network/Signaling Line Circuit (LON/SLC) monitoring in the Controller. The ASH is located directly on the LON of the EQP system, with a loop of up to 64 addressable devices tied into the ASH. This allows the EQP Controller to annunciate a fire alarm from either its own LON based I/O or from the ASH connected addressable detection loops

Documents

Description

The EQP Addressable Smoke and Heat (ASH) Module is designed to expand the input and output capability of the Det-Tronics Eagle Quantum Premier® system. The ASH is an interface device designed to provide continuous and automated fire protection. It ensures system operation through supervision of system inputs/outputs and Local Operating Network/Signaling Line Circuit (LON/SLC) monitoring in the Controller. The ASH is located directly on the LON of the EQP system, with a loop of up to 64 addressable devices tied into the ASH. This allows the EQP Controller to annunciate a fire alarm from either its own LON based I/O or from the ASH connected addressable detection loops

Additional information

Weight 2.7 lbs
Dimensions 4.56 × 6.31 × 2.00 in
Manufacturer

Detector Electronics Corportation

Brand

Condition

New

Unit of Measurement

EA (Each)

Production Status

Active

Eagle Quantum Premier ® Addressable Smoke & Heat (ASH) Module Model EQ3750ASH

Download

Det-Tronics - Data Sheet

Attributes

Weight 2.7 lbs
Dimensions 4.56 × 6.31 × 2.00 in
Manufacturer

Detector Electronics Corportation

Brand

Condition

New

Unit of Measurement

EA (Each)

Production Status

Active

Product Features

  • Expands the capabilities of the Det-Tronics Eagle Quantum Premier system.
  • EQP Controller can support up to 10 ASH modules on a loop (this support is dependant on system configuration and logic within S³).
  • Provides power and communications to 64 addressable devices.
  • Utilizes Apollo Discovery devices.
  • ASH alarm and fault conditions are logged in the EQP controller.
  • LEDs for easy annunciation of power, faults and an active device on the loop.
  • Monitors single addressable devices.
  • Provides remote I/O capabilities via LON/SCL.
  • DIN rail mounting.
  • Plug-in wiring connectors.
  • RFI and EMI hardened.
  • Approved for use in Marine applications (panel mount only).

What's Included

Shipping Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1 – 5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock. PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client.

Return Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee. New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made. See our complete return policy for more information at: https://firealarm.com/faq/

Testimonials

Rick A.
Dallas, TXI
Read More
"Great service. I received help with exactly what I needed and I received it all in a timely manner."
Charles O.
New Brunswick, NJ
Read More
"I had a big engineering/logistics issue that William over at FireAlarm.com helped me with. I don’t know what I would’ve done without their help!"
Jason G.
Los Angeles, CA
Read More
"The fastest delivery I’ve seen. Needed overnight emergency parts and I got just that."
Julia S.
Tampa, FL
Read More
"Needed last-minute maintenance done on my building’s system, and FireAlarm.com exceeded my expectations with how quickly it was done."

Leave a review

You may also like...

Pricing & Availability Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1 – 5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock. PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client.

Payment Details

You may remit payment via a US-Based Credit Card (CC Authorization Form), Wire Transfer (w/ $30 or $50 fee added to invoice), via PayPal (Or PayPal Pay Later), via Apple or Google Pay, or by mailing us a check. You can also call in with your credit card information at any time: 888-497-0290.

Return & Cancellation Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee. New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made. See our complete return policy for more information at: https://firealarm.com/faq/