Multispectrum IR Flame Detector; Aluminum, 4 Port, 3/4″ NPT, Relay and 0-20 mA Output, FM/CSA/ULC/ATEX/IECEx/VdS, Division/Zone Ex d e, Medium Sensitivity

Availability: Please Call for Availability
Condition: New
Brand: Det-Tronics
Status: Active
SKU: 163584
Manufacturer Part #: X3301A4N13W1
Secondary Part #: 028108-034

Description

The X3301 is a multispectrum infrared (MIR) flame detector. It provides unsurpassed detection of fires from light to heavy hydrocarbon fuels combined with the highest degree of false alarm rejection. The detector has Division and Zone explosionproof ratings and is suitable for use in indoor and outdoor applications. The X3301 contains three IR sensors with their associated signal processing circuitry. The standard output configuration includes fire alarm, fault and auxiliary relays, with an isolated 0 to 20 mA output model with optional HART communication.

Documents

Description

The X3301 is a multispectrum infrared (MIR) flame detector. It provides unsurpassed detection of fires from light to heavy hydrocarbon fuels combined with the highest degree of false alarm rejection. The detector has Division and Zone explosionproof ratings and is suitable for use in indoor and outdoor applications.

The X3301 contains three IR sensors with their associated signal processing circuitry. The standard output configuration includes fire alarm, fault and auxiliary relays, with an isolated 0 to 20 mA output model with optional HART communication.

Additional information

Weight 7 lbs
Manufacturer

Detector Electronics Corportation

Brand

Condition

New

Unit of Measurement

EA (Each)

Production Status

Active

Multispectrum IR Flame Detector; X3301

Download

Det-tronics - Data Sheet

2023 Det-Tronics Product Catalog

Download

Det-Tronics - Product Catalog

Attributes

Weight 7 lbs
Manufacturer

Detector Electronics Corportation

Brand

Condition

New

Unit of Measurement

EA (Each)

Production Status

Active

Product Features

  • Complies with FM 3260
  • EN54 certified
  • Certified SIL 2 capable
  • ATEX Directive compliant
  • Certified performance to multiple fuel types and fire sizes
  • EQP models available
  • Long detection range to carbonaceous fires
  • HART models available
  • FDT/DTM capable
  • Multiple sensitivity levels
  • Maximum false alarm rejection
  • Reliable flame detection with modulated IR background
  • Microprocessor controlled heated optics
  • Calibrated automatic optical check for each sensor eliminates need for testing with external test lamp
  • RFI and EMC Directive compliant
  • Event logging with time and date stamp
  • Integral wiring compartment for ease of installation
  • Operates under adverse weather conditions and in dirty environments

What's Included

Shipping Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1 – 5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock. PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client.

Return Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee. New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made. See our complete return policy for more information at: https://firealarm.com/faq/

Testimonials

Rick A.
Dallas, TXI
Read More
"Great service. I received help with exactly what I needed and I received it all in a timely manner."
Charles O.
New Brunswick, NJ
Read More
"I had a big engineering/logistics issue that William over at FireAlarm.com helped me with. I don’t know what I would’ve done without their help!"
Jason G.
Los Angeles, CA
Read More
"The fastest delivery I’ve seen. Needed overnight emergency parts and I got just that."
Julia S.
Tampa, FL
Read More
"Needed last-minute maintenance done on my building’s system, and FireAlarm.com exceeded my expectations with how quickly it was done."

Leave a review

Pricing & Availability Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1 – 5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock. PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client.

Payment Details

You may remit payment via a US-Based Credit Card (CC Authorization Form), Wire Transfer (w/ $30 or $50 fee added to invoice), via PayPal (Or PayPal Pay Later), via Apple or Google Pay, or by mailing us a check. You can also call in with your credit card information at any time: 888-497-0290.

Return & Cancellation Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee. New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made. See our complete return policy for more information at: https://firealarm.com/faq/