Det-Tronics X9800A4N11W1 (008700-006)

$6,769.62

Single Frequency IR Flame Detector

Availability: Please Call for Availability
Condition: New
Brand: Det-Tronics
Status: Active
SKU: 128238
Manufacturer Part #: X9800A4N11W1
Secondary Part #: 008700-006

Description

The evolution continues with the new X9800 IR Flame Detector. The X9800 meets the most stringent requirements worldwide with advanced detection capabilities and immunity to extraneous sources, combined with a superior mechanical design. The detector is equipped with automatic, manual and magnetic oi® test capability. The detector has Division and Zone explosion-proof ratings and is suitable for use in indoor and outdoor applications.

Documents

Description

The evolution continues with the new X9800 IR Flame Detector. The X9800 meets the most stringent requirements worldwide with advanced detection capabilities and immunity to extraneous sources, combined with a superior mechanical design. The detector is equipped with automatic, manual and magnetic oi® test capability. The detector has Division and Zone explosion-proof ratings and is suitable for use in indoor and outdoor applications.

Additional information

Weight 7 lbs
Manufacturer

Carrier

Brand

Condition

New

Production Status

Active

IR Flame Detector; Model X9800

Download

Det-Tronics - Data Sheet

Flame, Gas, and Systems

Download

Det-Tronics – Product Catalog

Attributes

Weight 7 lbs
Manufacturer

Carrier

Brand

Condition

New

Production Status

Active

Product Features

  • Complies with FM 3260
  • EN54 certified
  • Certified SIL 2 capable
  • ATEX Directive compliant
  • EQP models available
  • TDSA (Time Domain Signal Analysis) false alarm rejection
  • Responds to a fire in the presence of modulated blackbody radiation (i.e. heaters, ovens, turbines) without false alarm
  • HART models available
  • High speed capability
  • Microprocessor controlled heated optics for increased resistance to moisture and ice
  • Automatic, manual or magnetic oi® (optical integrity) testing — no external test lamp required
  • Easily replaceable oi plate
  • Fire, fault and auxiliary relays standard
  • MODBUS RS-485 communication
  • 0 to 20 mA isolated output (optional)
  • Pulse output for compatibility with controller based systems (optional)
  • A tricolor LED on the detector faceplate indicates normal condition and notifies personnel of fire alarm or fault conditions
  • Mounting arm allows easy sighting
  • Integral wiring compartment for ease of installation
  • Class A wiring per NFPA-72
  • Meets NFPA-33 response requirement for under 0.5 second (available when model selected)
  • RFI and EMC Directive compliant
  • Built-in data logging/event monitoring

What's Included

Shipping Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1 – 5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock. PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client.

Return Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee. New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made. See our complete return policy for more information at: https://firealarm.com/faq/

Testimonials

Rick A.
Dallas, TXI
Read More
"Great service. I received help with exactly what I needed and I received it all in a timely manner."
Charles O.
New Brunswick, NJ
Read More
"I had a big engineering/logistics issue that William over at FireAlarm.com helped me with. I don’t know what I would’ve done without their help!"
Jason G.
Los Angeles, CA
Read More
"The fastest delivery I’ve seen. Needed overnight emergency parts and I got just that."
Julia S.
Tampa, FL
Read More
"Needed last-minute maintenance done on my building’s system, and FireAlarm.com exceeded my expectations with how quickly it was done."

Leave a review

Pricing & Availability Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1 – 5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock. PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client.

Payment Details

You may remit payment via a US-Based Credit Card (CC Authorization Form), Wire Transfer (w/ $30 or $50 fee added to invoice), via PayPal (Or PayPal Pay Later), via Apple or Google Pay, or by mailing us a check. You can also call in with your credit card information at any time: 888-497-0290.

Return & Cancellation Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee. New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made. See our complete return policy for more information at: https://firealarm.com/faq/