E2S D2xB1LD3DC024MN0H1C

$1,178.40

LED Beacon 82.1cd/112.5cd, Clear Lens

Availability: Estimated 30 days
Condition: New
Brand: E2S
Status: Active
SKU: 176953
Manufacturer Part #: D2xB1LD3DC024MN0H1C
Secondary Part #: 1430570

Description

The haz loc D2xB1LD3 is an auto-synchronizing LED warning light/beacon tested to UL1971 for public mode fire alarm, ADA compliant, hearing-impaired applications. It has a UL1971 effective candela rating of 82.1cd and is NFPA 72 compliant with a 20ms pulse. The D2xB1LD3 utilizes an array of super high-power Cree® LEDs, oriented to optimize visibility in any direction. The 20ms pulse creates an intense flash comparative to a Xenon strobe. Multiple D2xB1LD3 units will auto-synchronize when powered from the same power source, removing the need for any additional sync modules on the circuit. The D2xB1LD3 contains a supervisory diode and duplicated pluggable terminals that not only simplify installation but also enable a 4-wire connection. The unit is UL, cUL, ULC, ATEX, and IECEx approved for hazardous area applications.

Documents

Description

The haz loc D2xB1LD3 is an auto-synchronizing LED warning light/beacon tested to UL1971 for public mode fire alarm, ADA compliant, hearing-impaired applications. It has a UL1971 effective candela rating of 82.1cd and is NFPA 72 compliant with a 20ms pulse.

The D2xB1LD3 utilizes an array of super high-power Cree® LEDs, oriented to optimize visibility in any direction. The 20ms pulse creates an intense flash comparative to a Xenon strobe. Multiple D2xB1LD3 units will auto-synchronize when powered from the same power source, removing the need for any additional sync modules on the circuit.

The D2xB1LD3 contains a supervisory diode and duplicated pluggable terminals that not only simplify installation but also enable a 4-wire connection. The unit is UL, cUL, ULC, ATEX, and IECEx approved for hazardous area applications.

Additional information

Weight 3.31 lbs
Dimensions 5.12 × 6.61 × 5.12 in
Manufacturer

E2S Warning Signals

Brand

Condition

New

Unit of Measurement

EA (Each)

Production Status

Active

D2xB1LD3 UL1971 Haz Loc Synchronized LED Light

Download

E2S - Data Sheet

D2XB1LD3 LED Beacons (Visual Fire Alarm) For use in Hazardous Locations

Download

E2S - Installation Instructions

Attributes

Weight 3.31 lbs
Dimensions 5.12 × 6.61 × 5.12 in
Manufacturer

E2S Warning Signals

Brand

Condition

New

Unit of Measurement

EA (Each)

Production Status

Active

Product Features

  • Public mode fire use UL1971 & CAN/ULC-S526
  • Private mode fire use UL1638
  • Synchronised for over 2 hours per UL1971
  • 1 eff. candela – UL1971 Public mode fire
  • 5 eff. candela – UL1638 Private mode fire
  • 0 eff. candela – UL1638 General signaling
  • Ultra low operating current of 153mA
  • In rush limiting circuit: 1.18A
  • Choice of four UL1971 tested flash rates: 1Hz, 1.3Hz, 1.5Hz & 2Hz
  • Marine grade aluminum enclosure
  • Ingress protection Type 4/4X/3R/13, IP66
  • High impact resistant Borosilicate glass lens
  • Duplicate, pluggable cable terminations, supervisory diode
  • Surface mounting via user installed lugs
  • Pendant mounting via 3/4″NPT conduit entry
  • Dual 1/2″NPT and M20 cable entries
  • Supplied with haz loc rated stopping plugs/adaptors

What's Included

Shipping Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1 – 5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock. PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client.

Return Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee. New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made. See our complete return policy for more information at: https://firealarm.com/faq/

Testimonials

Rick A.
Dallas, TXI
Read More
"Great service. I received help with exactly what I needed and I received it all in a timely manner."
Charles O.
New Brunswick, NJ
Read More
"I had a big engineering/logistics issue that William over at FireAlarm.com helped me with. I don’t know what I would’ve done without their help!"
Jason G.
Los Angeles, CA
Read More
"The fastest delivery I’ve seen. Needed overnight emergency parts and I got just that."
Julia S.
Tampa, FL
Read More
"Needed last-minute maintenance done on my building’s system, and FireAlarm.com exceeded my expectations with how quickly it was done."

Leave a review

Pricing & Availability Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1 – 5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock. PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client.

Payment Details

You may remit payment via a US-Based Credit Card (CC Authorization Form), Wire Transfer (w/ $30 or $50 fee added to invoice), via PayPal (Or PayPal Pay Later), via Apple or Google Pay, or by mailing us a check. You can also call in with your credit card information at any time: 888-497-0290.

Return & Cancellation Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee. New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made. See our complete return policy for more information at: https://firealarm.com/faq/