This product has been replaced by

Edwards EC2-H

Heat Detector Head Only, 135°F Fixed/Rate-of-Rise

Manufacturer Part #: EC2-H

Edwards EC2-H

$29.54

Heat Detector Head Only, 135°F Fixed/Rate-of-Rise

Availability: In Stock
Condition: New
Brand: Edwards
Status: Active
SKU: 69328
Manufacturer Part #: EC2-H

Description

The Edwards conventional photoelectric smoke and heat detectors are interchangeable head and base detectors using Optica smoke sensing technology and high accuracy heat sensor that provides outstanding stability and excellent response to a wide range of fires.

Like their Signature series counterparts, EC2 smoke detectors feature a photoelectric chamber using Optica sensing technology providing multi criteria response discriminating real smoke from other nuisance sources. A single tri-color LED located on the housing provides alarm, trouble and standby indications.

EC2-H is a heat only detector comprised of a heat sensor with a 135 fixed threshold and rate of rise compensation.

Documents

Description

The Edwards conventional photoelectric smoke and heat detectors are interchangeable head and base detectors using Optica smoke sensing technology and high accuracy heat sensor that provides outstanding stability and excellent response to a wide range of fires.

Like their Signature series counterparts, EC2 smoke detectors feature a photoelectric chamber using Optica sensing technology providing multi criteria response discriminating real smoke from other nuisance sources. A single tri-color LED located on the housing provides alarm, trouble and standby indications.

EC2-H is a heat only detector comprised of a heat sensor with a 135 fixed threshold and rate of rise compensation.

Additional information

Weight 0.2 lbs
Dimensions 4.00 × 4.00 × 1.75 in
Manufacturer

Carrier

Brand

Condition

New

Type

Detector

Color

White

Connection

Two-Wire

Detectable Medium

Heat

Detection Method

Fixed Temperature, Rate-of-Rise

Thermal Rating

135°F

Series

Production Status

Active

Reviews

There are no reviews yet.

Be the first to review “Edwards EC2-H”

Conventional 2-Wire Smoke & Heat Detectors

Download

Edwards - Data Sheet

Attributes

Weight 0.2 lbs
Dimensions 4.00 × 4.00 × 1.75 in
Manufacturer

Carrier

Brand

Condition

New

Type

Detector

Color

White

Connection

Two-Wire

Detectable Medium

Heat

Detection Method

Fixed Temperature, Rate-of-Rise

Thermal Rating

135°F

Series

Production Status

Active

Product Features

  • Self-diagnostic capability continually monitors operation
  • Meets NFPA 72 sensitivity test requirements
  • Head and terminal base design (base sold separately)
  • Automatic drift compensation
  • Tri-color status LED, solid red for alarm, flashing yellow for trouble and flashing green for standby
  • Low-profile design blends into the ceiling
  • Advanced nuisance discrimination from non fire sources like cooking smoke and non condensing water vapor

What's Included

Shipping Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1 – 5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock. PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client.

Return Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee. New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made. See our complete return policy for more information at: https://firealarm.com/faq/

Testimonials

Rick A.
Dallas, TXI
Read More
"Great service. I received help with exactly what I needed and I received it all in a timely manner."
Charles O.
New Brunswick, NJ
Read More
"I had a big engineering/logistics issue that William over at FireAlarm.com helped me with. I don’t know what I would’ve done without their help!"
Jason G.
Los Angeles, CA
Read More
"The fastest delivery I’ve seen. Needed overnight emergency parts and I got just that."
Julia S.
Tampa, FL
Read More
"Needed last-minute maintenance done on my building’s system, and FireAlarm.com exceeded my expectations with how quickly it was done."

Leave a review

Reviews

There are no reviews yet.

Be the first to review “Edwards EC2-H”

You may also like...

Pricing & Availability Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1 – 5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock. PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client.

Payment Details

You may remit payment via a US-Based Credit Card (CC Authorization Form), Wire Transfer (w/ $30 or $50 fee added to invoice), via PayPal (Or PayPal Pay Later), via Apple or Google Pay, or by mailing us a check. You can also call in with your credit card information at any time: 888-497-0290.

Return & Cancellation Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee. New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made. See our complete return policy for more information at: https://firealarm.com/faq/