Edwards MN-NETRLY4

$596.21

Ethernet controllable multi I/O unit, 4 input 4 relay outputs

Availability: In Stock
Condition: New
Brand: Edwards
Status: Active
SKU: 48005
Manufacturer Part #: MN-NETRLY4

Description

The EDWARDS MN-NETLRY4 Network Relay provides four un- supervised input zones and four normally-open relays to and from FireWorks V1.6 or greater over an Ethernet (TCP/IP) network. This module is particularly well-suited for mass notification, life safety applications, and other monitoring or output applications. It is also ideal for interfacing to third-party systems. The MN-NETRLY4’s four input zones may be configured as Alarm, Supervisory, Trouble, or Monitor inputs directly into FireWorks. These can initiate display events and trigger FireWorks logic. The wiring for these zones is limited to 20 ft (6.1 m), and must be mechanically protected in accordance with applicable codes. The four normally-open relays are controlled directly from Fire- Works. These can be programmed to respond to automatic or manual FireWorks commands. Data communication to and from the MN-NETLRY4 is constantly supervised from FireWorks. A fixed IP address is required. The MN-NETRLY4 snaps easily onto the included DIN rail (MN- NRBK1) mounting bracket that can be mounted in an 2-WB, EST3 (on MN-BRKT1), MFC-A, APS(6)(10)A (on MN-BRKT3), or BPS(6) (10)A enclosure. An optional MN-NRMP is also available that will allow two MN-NETLRY4s to be mounted on an MN-BRKT1 in place of an MN-FVPN.

Documents

Description

The EDWARDS MN-NETLRY4 Network Relay provides four un- supervised input zones and four normally-open relays to and from FireWorks V1.6 or greater over an Ethernet (TCP/IP) network. This module is particularly well-suited for mass notification, life safety applications, and other monitoring or output applications. It is also ideal for interfacing to third-party systems.

The MN-NETRLY4’s four input zones may be configured as Alarm, Supervisory, Trouble, or Monitor inputs directly into FireWorks. These can initiate display events and trigger FireWorks logic. The wiring for these zones is limited to 20 ft (6.1 m), and must be mechanically protected in accordance with applicable codes.

The four normally-open relays are controlled directly from Fire- Works. These can be programmed to respond to automatic or manual FireWorks commands.

Data communication to and from the MN-NETLRY4 is constantly supervised from FireWorks. A fixed IP address is required.

The MN-NETRLY4 snaps easily onto the included DIN rail (MN- NRBK1) mounting bracket that can be mounted in an 2-WB, EST3 (on MN-BRKT1), MFC-A, APS(6)(10)A (on MN-BRKT3), or BPS(6) (10)A enclosure. An optional MN-NRMP is also available that will allow two MN-NETLRY4s to be mounted on an MN-BRKT1 in place of an MN-FVPN.

Additional information

Weight 1 lbs
Construction

Polymer

Series

Condition

New

Brand

Production Status

Active

Reviews

There are no reviews yet.

Be the first to review “Edwards MN-NETRLY4”

Ethernet Network I/O Module; MN-NETRLY4

Download

Edwards - Data Sheet

Attributes

Weight 1 lbs
Construction

Polymer

Series

Condition

New

Brand

Production Status

Active

Product Features

  • Flexible mounting options
  • Powered by 24 Vdc from control panel or listed power supply
  • Easy to configure
  • Removable terminal strips
  • Optional MN-TK10 Terminal Block Kit

What's Included

Shipping Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1 – 5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock. PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client.

Return Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee. New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made. See our complete return policy for more information at: https://firealarm.com/faq/

Testimonials

Rick A.
Dallas, TXI
Read More
"Great service. I received help with exactly what I needed and I received it all in a timely manner."
Charles O.
New Brunswick, NJ
Read More
"I had a big engineering/logistics issue that William over at FireAlarm.com helped me with. I don’t know what I would’ve done without their help!"
Jason G.
Los Angeles, CA
Read More
"The fastest delivery I’ve seen. Needed overnight emergency parts and I got just that."
Julia S.
Tampa, FL
Read More
"Needed last-minute maintenance done on my building’s system, and FireAlarm.com exceeded my expectations with how quickly it was done."

Leave a review

Reviews

There are no reviews yet.

Be the first to review “Edwards MN-NETRLY4”

Pricing & Availability Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1 – 5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock. PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client.

Payment Details

You may remit payment via a US-Based Credit Card (CC Authorization Form), Wire Transfer (w/ $30 or $50 fee added to invoice), via PayPal (Or PayPal Pay Later), via Apple or Google Pay, or by mailing us a check. You can also call in with your credit card information at any time: 888-497-0290.

Return & Cancellation Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee. New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made. See our complete return policy for more information at: https://firealarm.com/faq/