Description

The Genesis line of chimes and strobes are audible-visible emergency signaling devices. Protruding no more than one inch from the wall, Genesis chimes and chime-strobes feature textured housings in white or red. Genesis strobes are designed to channel and condition light to produce a highly controllable distribution pattern. Chime-strobes feature selectable candela output with a switch located on the bottom of the device. The candela setting is visible even after the device is installed. The strobes are designed to flash at the same rate (synchronize) when used with a compatible synchronization source, such as the EG1-M and EG1M-RM synchronization module, E-FSC and E-FSA fire panels, and EBPS series booster supplies. Genesis Series chimes 60 strokes per minute when steady voltage is applied, or may be field-configured for temporal output. When installed with a EG1M Signal Master Module, the chime may also be field-configured for coded operation. Chimes may be set for low dB output with a jumper cut that reduces sound output.

Documents

Description

The Genesis line of chimes and strobes are audible-visible emergency signaling devices. Protruding no more than one inch from the wall, Genesis chimes and chime-strobes feature textured housings in white or red. Genesis strobes are designed to channel and condition light to produce a highly controllable distribution pattern.

Chime-strobes feature selectable candela output with a switch located on the bottom of the device. The candela setting is visible even after the device is installed.

The strobes are designed to flash at the same rate (synchronize) when used with a compatible synchronization source, such as the EG1-M and EG1M-RM synchronization module, E-FSC and E-FSA fire panels, and EBPS series booster supplies.

Genesis Series chimes 60 strokes per minute when steady voltage is applied, or may be field-configured for temporal output. When installed with a EG1M Signal Master Module, the chime may also be field-configured for coded operation. Chimes may be set for low dB output with a jumper cut that reduces sound output.

Additional information

Weight 0.4 lbs
Color

Red

Marking

FIRE

Mounting

Flush, Surface, Wall

Series

,

Brand

Production Status

Active

Reviews

There are no reviews yet.

Be the first to review “Edwards Signaling EG1FR-C”

Conventional and Addressable Accessories Chimes and Strobes Genesis Series

Download

Edwards Signaling - Product Catalog

Conventional and Addressable Accessories Chimes and Strobes Genesis Series

Download

Edwards Signaling - Product Catalog

Attributes

Weight 0.4 lbs
Color

Red

Marking

FIRE

Mounting

Flush, Surface, Wall

Series

,

Brand

Production Status

Active

Product Features

  • Xenon light source
  • Clear lens
  • White or red housing
  • Low profile design
  • Field selectable candela output via switch
  • 81dB @ 1m/71dB @ 10ft. output
  • Fits standard single gang electrical boxes – no extension ring or trim plate required
  • Operating temperature range: 32°F to 120°F (0°C to 49°C)

What's Included

Shipping Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1 – 5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock. PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client.

Return Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee. New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made. See our complete return policy for more information at: https://firealarm.com/faq/

Testimonials

Rick A.
Dallas, TXI
Read More
"Great service. I received help with exactly what I needed and I received it all in a timely manner."
Charles O.
New Brunswick, NJ
Read More
"I had a big engineering/logistics issue that William over at FireAlarm.com helped me with. I don’t know what I would’ve done without their help!"
Jason G.
Los Angeles, CA
Read More
"The fastest delivery I’ve seen. Needed overnight emergency parts and I got just that."
Julia S.
Tampa, FL
Read More
"Needed last-minute maintenance done on my building’s system, and FireAlarm.com exceeded my expectations with how quickly it was done."

Leave a review

Reviews

There are no reviews yet.

Be the first to review “Edwards Signaling EG1FR-C”

Pricing & Availability Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1 – 5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock. PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client.

Payment Details

You may remit payment via a US-Based Credit Card (CC Authorization Form), Wire Transfer (w/ $30 or $50 fee added to invoice), via PayPal (Or PayPal Pay Later), via Apple or Google Pay, or by mailing us a check. You can also call in with your credit card information at any time: 888-497-0290.

Return & Cancellation Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee. New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made. See our complete return policy for more information at: https://firealarm.com/faq/