This product has been replaced by

Fike FIK-UV-IR-F-HD-AS21

Flame Detector, SS316, 2 x 3/4” NPT entries, Color VID, standard configuration

Manufacturer Part #: FIK-UV-IR-F-HD-AS21

Fike FIK-UV-IR-F-HD-AS21

$5,158.54

Flame Detector, SS316, 2 x 3/4” NPT entries, Color VID, standard configuration

Availability: Estimated 26 days
Condition: New
Brand: Fike
Status: Active
SKU: 126223
Manufacturer Part #: FIK-UV-IR-F-HD-AS21

Description

The UV-IR-F-HD flame detector provides ultra-fast response, high performance and reliable detection of a large variety of fires including hydrocarbon fires (visible and non-visible). The detector uses improved UV-IR to address both slow-growing fires and fast eruptions of fire, operating in all weather and light conditions.

The detector provides high-definition (HD) video output of the monitored area with clear imaging of a fire event and of personnel at distances up to 100 ft. (30m) allowing rescuers to know the exact situation before entering the hazardous area. It will automatically record a video of a fire event (1 min pre-alarm / up to 3 min post-alarm).

The integral HD quality video, with event recording, on top of the proven superior capabilities of UV-IR flame detection and you have a very powerful safety tool to protect personnel, the plant and process.

Documents

Description

The UV-IR-F-HD flame detector provides ultra-fast response, high performance and reliable detection of a large variety of fires including hydrocarbon fires (visible and non-visible). The detector uses improved UV-IR to address both slow-growing fires and fast eruptions of fire, operating in all weather and light conditions.

The detector provides high-definition (HD) video output of the monitored area with clear imaging of a fire event and of personnel at distances up to 100 ft. (30m) allowing rescuers to know the exact situation before entering the hazardous area. It will automatically record a video of a fire event (1 min pre-alarm / up to 3 min post-alarm).

The integral HD quality video, with event recording, on top of the proven superior capabilities of UV-IR flame detection and you have a very powerful safety tool to protect personnel, the plant and process.

Additional information

Weight 9.8 lbs
Dimensions 7.87 × 5.12 × 5.12 in
Manufacturer

Fire & Gas Detection Technologies, Inc.

Brand

Condition

New

Unit of Measurement

EA (Each)

Production Status

Active

UV-IR-F-HD Flame Detector

Download

Fike - Data Sheet

Fike Flame Detector Setup

Download

Fike - Quick Start Guide

FIK-UV-IR-F-HD Flame Detector

Download

Fike - User Manual

Attributes

Weight 9.8 lbs
Dimensions 7.87 × 5.12 × 5.12 in
Manufacturer

Fire & Gas Detection Technologies, Inc.

Brand

Condition

New

Unit of Measurement

EA (Each)

Production Status

Active

Product Features

  • High immunity to false alarm
  • Ultra-fast detection mode detection within 5 milliseconds for fireballs or explosions
  • Hydrocarbon flame detection. Spectrum response of IR radiation in the 4.0-5.0 micron range
  • High sensitivity – up to 100 ft. (30m) for a 1 ft2 (0.1m2) n-heptane pan fire
  • HD video output with Automatic HD video recording of fire events. Data /Event logger – alarms, faults and other relevant events are logged to non-volatile memory
  • Ethernet communication – in addition to the standard methods, such as 4-20mA and Modbus
  • Built-in-Test (BIT) – Automatic and manual internal self-test of window cleanliness and the overall operation of the detector
  • Window heater to avoid condensation and icing
  • Stainless steel tilt mount with horizontal and vertical adjustment
  • Detects high UV (sparks and arcs) or IR levels via auxiliary relay and 4-20mA
  • Meets NFPA 33 response requirement for flame detection within 0.5 second

What's Included

Shipping Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1 – 5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock. PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client.

Return Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee. New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made. See our complete return policy for more information at: https://firealarm.com/faq/

Testimonials

Rick A.
Dallas, TXI
Read More
"Great service. I received help with exactly what I needed and I received it all in a timely manner."
Charles O.
New Brunswick, NJ
Read More
"I had a big engineering/logistics issue that William over at FireAlarm.com helped me with. I don’t know what I would’ve done without their help!"
Jason G.
Los Angeles, CA
Read More
"The fastest delivery I’ve seen. Needed overnight emergency parts and I got just that."
Julia S.
Tampa, FL
Read More
"Needed last-minute maintenance done on my building’s system, and FireAlarm.com exceeded my expectations with how quickly it was done."

Leave a review

You may also like...

Pricing & Availability Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1 – 5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock. PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client.

Payment Details

You may remit payment via a US-Based Credit Card (CC Authorization Form), Wire Transfer (w/ $30 or $50 fee added to invoice), via PayPal (Or PayPal Pay Later), via Apple or Google Pay, or by mailing us a check. You can also call in with your credit card information at any time: 888-497-0290.

Return & Cancellation Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee. New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made. See our complete return policy for more information at: https://firealarm.com/faq/