Hochiki FN-642-ULADA-R

$1,074.13

Power Extender, 6 AMP, 4-Circuit, 12/24VDC, Red

Availability: Please Call for Availability
Condition: New
Brand: Hochiki
Status: Active
SKU: 51954
Manufacturer Part #: FN-642-ULADA-R
Secondary Part #: 0500-02350

Description

The FN-642-ULADA, FN-842-ULADA, and FN-1042-ULADA are extremely cost effective voltage regulated remote NAC Power Extenders. They may be connected to any 12 or 24VDC Fire Alarm Control Panel (FACP). Primary applications include Notification Appliance Circuit (NAC) expansion (supports ADA requirements) and will provide auxiliary power to support system accessories.

Documents

Description

The FN-642-ULADA, FN-842-ULADA, and FN-1042-ULADA are extremely cost effective voltage regulated remote NAC Power Extenders. They may be connected to any 12 or 24VDC Fire Alarm Control Panel (FACP). Primary applications include Notification Appliance Circuit (NAC) expansion (supports ADA requirements) and will provide auxiliary power to support system accessories.

Additional information

Weight 15 lbs
Dimensions 4.625 × 14.50 × 18.00 in
Color

Red

Condition

New

Brand

Production Status

Active

Reviews

There are no reviews yet.

Be the first to review “Hochiki FN-642-ULADA-R”

Attributes

Weight 15 lbs
Dimensions 4.625 × 14.50 × 18.00 in
Color

Red

Condition

New

Brand

Production Status

Active

Product Features

  • Two (2) Class A or (2) Class B FACP inputs
  • Two (2) NC dry contact trigger inputs
  • Four (4) Class A or Four (4) Class B indicating circuits
  • Two (2) Class B outputs may be paralleled for more power on an indicating circuit
  • One (1) Aux. Power Output @ 1 amp supply current (with or without battery backup)
  • Signal Circuit Trouble Memory – Facilitates quickly locating intermittent system trouble and eliminates costly and unnecessary service calls. LED’s indicate a prior fault (short, open, ground) has occurred on one or more signaling circuit outputs.
  • 2 wire Horn/Strobe Sync mode allows audible notification appliances (Horns) to be silenced while visual notification appliances (Strobes) continue to operate
  • Horn/Strobe sync protocols include: Gentex, System Sensor, Faraday, Wheelock and Amseco.
  • Temporal Code 3 Mode
  • Steady Mode
  • Input to Output Follower Mode (maintains synchronization of notification appliance circuits)
  • March Time
  • Compatible with 24VDC or 12VDC fire panels
  • Input 115VAC
  • AC fail, battery presence & low battery monitoring
  • Accommodates up to two (2) 12VDC/12AH batteries
  • Power supply, logic board, red enclosure, cam lock, transformer & battery leads

What's Included

Shipping Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1 – 5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock. PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client.

Return Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee. New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made. See our complete return policy for more information at: https://firealarm.com/faq/

Testimonials

Rick A.
Dallas, TXI
Read More
"Great service. I received help with exactly what I needed and I received it all in a timely manner."
Charles O.
New Brunswick, NJ
Read More
"I had a big engineering/logistics issue that William over at FireAlarm.com helped me with. I don’t know what I would’ve done without their help!"
Jason G.
Los Angeles, CA
Read More
"The fastest delivery I’ve seen. Needed overnight emergency parts and I got just that."
Julia S.
Tampa, FL
Read More
"Needed last-minute maintenance done on my building’s system, and FireAlarm.com exceeded my expectations with how quickly it was done."

Leave a review

Reviews

There are no reviews yet.

Be the first to review “Hochiki FN-642-ULADA-R”

Pricing & Availability Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1 – 5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock. PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client.

Payment Details

You may remit payment via a US-Based Credit Card (CC Authorization Form), Wire Transfer (w/ $30 or $50 fee added to invoice), via PayPal (Or PayPal Pay Later), via Apple or Google Pay, or by mailing us a check. You can also call in with your credit card information at any time: 888-497-0290.

Return & Cancellation Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee. New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made. See our complete return policy for more information at: https://firealarm.com/faq/