Description

Searchpoint Optima Plus is a micro-processor controlled, Infrared Gas Detector with comprehensive built-in self diagnostic and fault-finding facilities. An analogue 4 to 20mA output and digital communications are provided as standard. Full two-way communication allows calibration and advanced self-checking procedures to be used. To take advantage of these features a Hand-Held Interrogator unit may be connected to a Termination Unit or via the SHC Protection Device to other junction boxes.

Documents

Description

Searchpoint Optima Plus is a micro-processor controlled, Infrared Gas Detector with comprehensive built-in self diagnostic and fault-finding facilities. An analogue 4 to 20mA output and digital communications are provided as standard. Full two-way communication allows calibration and advanced self-checking procedures to be used. To take advantage of these features a Hand-Held Interrogator unit may be connected to a Termination Unit or via the SHC Protection Device to other junction boxes.

Additional information

Weight 3.53 lbs
Brand

Condition

New

Production Status

Active

Sieger Searchpoint Optima Plus

Download

Honeywell - Data Sheet

Attributes

Weight 3.53 lbs
Brand

Condition

New

Production Status

Active

Product Features

  • Failsafe operation
  • Fast speed of response
  • Reduced routine maintenance
  • Immune to catalytic poisons
  • Long operating life
  • Works in inert atmospheres
  • Experience gained from over 100,000 units installed worldwide
  • Improved reliability
  • Optional HART® over 4-20mA output
  • Can detect a wide range of hydrocarbon gases including solvents
  • Increased reliability with no moving parts
  • Increased stability from self compensating optics
  • Immune to long term component drift
  • Remote functional gas test facility
  • Certified for North American and European Hazardous areas
  • Increased false alarm rejection
  • Increased uptime with contaminated optics warning
  • Dynamic Heating Control ensures condensation free optics
  • No undetected failures
  • Improved diagnostics
  • Integral event logging
  • Reduced power consumption
  • Certified to many hazardous area classification schemes including: European (ATEX), UL, CSA, IECEx and more

What's Included

Shipping Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1 – 5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock. PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client.

Return Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee. New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made. See our complete return policy for more information at: https://firealarm.com/faq/

Testimonials

Rick A.
Dallas, TXI
Read More
"Great service. I received help with exactly what I needed and I received it all in a timely manner."
Charles O.
New Brunswick, NJ
Read More
"I had a big engineering/logistics issue that William over at FireAlarm.com helped me with. I don’t know what I would’ve done without their help!"
Jason G.
Los Angeles, CA
Read More
"The fastest delivery I’ve seen. Needed overnight emergency parts and I got just that."
Julia S.
Tampa, FL
Read More
"Needed last-minute maintenance done on my building’s system, and FireAlarm.com exceeded my expectations with how quickly it was done."

Leave a review

You may also like...

Pricing & Availability Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1 – 5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock. PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client.

Payment Details

You may remit payment via a US-Based Credit Card (CC Authorization Form), Wire Transfer (w/ $30 or $50 fee added to invoice), via PayPal (Or PayPal Pay Later), via Apple or Google Pay, or by mailing us a check. You can also call in with your credit card information at any time: 888-497-0290.

Return & Cancellation Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee. New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made. See our complete return policy for more information at: https://firealarm.com/faq/