Description

The JCPU2-3030D is a part of the IFC2-3030 unit which is an intelligent Fire Alarm Control Panel designed for medium- to large-scale facilities. Fire emergency detection and evacuation are extremely critical to life safety, and the IFC2-3030 is ideally suited for these applications. The IFC2-3030 is ideal for virtually any application because it features a modular design that is configured per project requirements. With one to ten Signaling Line Circuits (SLCs), the IFC2- 3030 supports up to 3,180 intelligent addressable devices. Information is critical to fire evacuation personnel, and the IFC2- 3030’s large 640-character Liquid Crystal Display (LCD) presents vital information to operators concerning a fire situation, fire progression, and evacuation details.

Documents

Description

The JCPU2-3030D is a part of the IFC2-3030 unit which is an intelligent Fire Alarm Control Panel designed for medium- to large-scale facilities. Fire emergency detection and evacuation are extremely critical to life safety, and the IFC2-3030 is ideally suited for these applications. The IFC2-3030 is ideal for virtually any application because it features a modular design that is configured per project requirements. With one to ten Signaling Line Circuits (SLCs), the IFC2- 3030 supports up to 3,180 intelligent addressable devices. Information is critical to fire evacuation personnel, and the IFC2- 3030’s large 640-character Liquid Crystal Display (LCD) presents vital information to operators concerning a fire situation, fire progression, and evacuation details.

Additional information

Weight 16 lbs
Manufacturer

Johnson Controls

Brand

Condition

New

Type

Control Panel

Style

Addressable

Color

N/A

Series

Production Status

Active

Compatibility

Reviews

There are no reviews yet.

Be the first to review “Johnson Controls JCPU2-3030D”

Attributes

Weight 16 lbs
Manufacturer

Johnson Controls

Brand

Condition

New

Type

Control Panel

Style

Addressable

Color

N/A

Series

Production Status

Active

Compatibility

Product Features

  • Listed to UL Standard 864, 9th edition.
  • One to ten isolated intelligent Signaling Line Circuits (SLC) Style 4, 6 or 7.
  • Up to 159 detectors (any mix of ion, photo, laser photo, thermal, or multi-sensor) and 159 modules (N.O. manual stations, two-wire smoke, notification, or relay) per SLC. 318 devices per loop/3180 per FACP or network node.
  • Large 640-character LCD backlit display (16 lines x 40 characters) or display-less (a node on a network).
  • Network option – supports IFC-640, IFC2-640, IFC-320, IFC3030, IFC2-3030, IFC-200, IFC-400, IFC-1010, IFC-2020, IFW Intelligent Fire Workstation, JNCA or JNCA-2 Network Annunciators.
  • Built-in Alarm, Trouble, Security, and Supervisory relays.
  • VeriFire® Tools online/offline program option.
  • Application code is saved in Flash memory, eliminating the need to change EPROMs.
  • Built-in Degraded Mode option. In the event of a CPU failure, the system is capable of general alarm if a fire condition is present.
  • Weekly Occupancy Schedules allow changing sensitivity by time of day and day of week.
  • Optional universal 2040-point DACT.
  • EIA-485 annunciators, including custom graphics.
  • History file with 4000-event capacity in nonvolatile memory, plus separate 1000-event alarm only file.
  • Advanced history filters allow sorting by event, time, date, or address.
  • Alarm Verification selection per point, with tally.
  • Autoprogramming and Walk Test reports.
  • Positive Alarm Sequence (PAS) Presignal.
  • Silence Inhibit and Auto Silence timer options.
  • Field-programmable on panel or on PC, with VeriFire Tools program, also check, compare.
  • Non-alarm points for lower priority functions.
  • Remote ACK/Signal Silence/System Reset/Drill via monitor modules.
  • Powerful Boolean logic equations — 1000!
  • Supports SCS Series smoke control system in both HVAC or FSCS modes.
  • EIA-232 printer port.
  • EIA-485 annunciator port.

What's Included

Shipping Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1 – 5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock. PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client.

Return Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee. New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made. See our complete return policy for more information at: https://firealarm.com/faq/

Testimonials

Rick A.
Dallas, TXI
Read More
"Great service. I received help with exactly what I needed and I received it all in a timely manner."
Charles O.
New Brunswick, NJ
Read More
"I had a big engineering/logistics issue that William over at FireAlarm.com helped me with. I don’t know what I would’ve done without their help!"
Jason G.
Los Angeles, CA
Read More
"The fastest delivery I’ve seen. Needed overnight emergency parts and I got just that."
Julia S.
Tampa, FL
Read More
"Needed last-minute maintenance done on my building’s system, and FireAlarm.com exceeded my expectations with how quickly it was done."

Leave a review

Reviews

There are no reviews yet.

Be the first to review “Johnson Controls JCPU2-3030D”

You may also like...

Pricing & Availability Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1 – 5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock. PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client.

Payment Details

You may remit payment via a US-Based Credit Card (CC Authorization Form), Wire Transfer (w/ $30 or $50 fee added to invoice), via PayPal (Or PayPal Pay Later), via Apple or Google Pay, or by mailing us a check. You can also call in with your credit card information at any time: 888-497-0290.

Return & Cancellation Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee. New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made. See our complete return policy for more information at: https://firealarm.com/faq/