The JNCA-2 is a second-generation Network Control Annunciator for the NOTI•FIRE•NET™ network, compatible for use with nodes such as the IFC2-3030, IFC-3030, IFC-320, IFC-640 and IFC2-640 fire alarm control panels, as well as first-generation JNCA Network Control Annunciators. Additionally, the JNCA-2 may be configured with JDVC Series products (JDVC, JDVC-EM, JDVCEMF, and JDVC-EMSF) to create one or more Digital Audio Command Centers on NOTI•FIRE•NET. The JNCA-2 provides system control and display capabilities for all, or for selected network nodes. The JNCA-2 display consists of a 640-character backlit LCD display, and a control interface consisting of “soft” keys used to navigate screen menus, “hard” keys with fixed control functions, and a QWERTY keypad. When connected to one or more networked panels the JNCA-2 provides network control and status/history display capabilities. It may also be configured as the Primary Display for displayless nodes on the network.

Documents

Description

The JNCA-2 is a second-generation Network Control Annunciator for the NOTI•FIRE•NET™ network, compatible for use with nodes such as the IFC2-3030, IFC-3030, IFC-320, IFC-640 and IFC2-640 fire alarm control panels, as well as first-generation JNCA Network Control Annunciators. Additionally, the JNCA-2 may be configured with JDVC Series products (JDVC, JDVC-EM, JDVCEMF, and JDVC-EMSF) to create one or more Digital Audio Command Centers on NOTI•FIRE•NET. The JNCA-2 provides system control and display capabilities for all, or for selected network nodes. The JNCA-2 display consists of a 640-character backlit LCD display, and a control interface consisting of “soft” keys used to navigate screen menus, “hard” keys with fixed control functions, and a QWERTY keypad. When connected to one or more networked panels the JNCA-2 provides network control and status/history display capabilities. It may also be configured as the Primary Display for displayless nodes on the network.

Additional information

Weight 2 lbs
Brand

Condition

New

Production Status

Active

Reviews

There are no reviews yet.

Be the first to review “Johnson Controls JNCA-2”

Attributes

Weight 2 lbs
Brand

Condition

New

Production Status

Active

Product Features

  • Listed to UL Standard 864, 9th edition.
  • Full supervision of all inputs and network integrity.
  • Enhanced-format 640-character LCD display with backlighting.
  • ACS bus for LED or graphic annunciators (EIA-485).
  • Optically isolated printer interface (EIA-232).
  • 11 LED status indicators: Power, Controls Active, Fire Alarm, Pre-Alarm, Security, Alert, Supervisory, Trouble, Signal, Silence, CPU Failure, Point Disabled, Other Event.
  • Alphanumeric QWERTY rubber keypad.
  • Four status relays: Alarm, Trouble, Supervisory, Security (Form-C).
  • Nonvolatile real-time clock can be synchronized with network by master node.
  • Optional Security Keyswitch enable Keypad functions.
  • Optional Security Tamper switch.
  • Supports up to 32 remote ACS annunciators and modules.
  • Requires 24 VDC, and a network connection.
  • RDP port for LCD-160 or terminal mode LCD-80.
  • Individual Enable/Disable or Group Enable/Disable local for networked compatible panels.
  • Control ON/OFF networked compatible panel control points.
  • Read Status networked compatible panel points and zones.
  • Network paging control/HVAC control requires SCS series.
  • Network-wide: Acknowledge, Silence, Reset.
  • Lamp Test (local to JNCA-2).
  • History Buffer (1000 Alarm events; 4000 System events).
  • Print JNCA-2 programming and history reports.
  • Report status of networked panels and their respective field devices to a central station via a single UDACT.
  • One Master level, nine User level passwords. The Master can assign each User access levels (programming, alter status).
  • Interactive Summary Event Count display, event handling package.
  • Online programming and alter-status programs.
  • Intuitive user guidance program including interactive soft keys.
  • Enhanced Read Status/Alter Status displays.

What's Included

Shipping Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1 – 5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock. PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client.

Return Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee. New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made. See our complete return policy for more information at: https://firealarm.com/faq/

Testimonials

Rick A.
Dallas, TXI
Read More
"Great service. I received help with exactly what I needed and I received it all in a timely manner."
Charles O.
New Brunswick, NJ
Read More
"I had a big engineering/logistics issue that William over at FireAlarm.com helped me with. I don’t know what I would’ve done without their help!"
Jason G.
Los Angeles, CA
Read More
"The fastest delivery I’ve seen. Needed overnight emergency parts and I got just that."
Julia S.
Tampa, FL
Read More
"Needed last-minute maintenance done on my building’s system, and FireAlarm.com exceeded my expectations with how quickly it was done."

Leave a review

Reviews

There are no reviews yet.

Be the first to review “Johnson Controls JNCA-2”

You may also like...

Pricing & Availability Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1 – 5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock. PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client.

Payment Details

You may remit payment via a US-Based Credit Card (CC Authorization Form), Wire Transfer (w/ $30 or $50 fee added to invoice), via PayPal (Or PayPal Pay Later), via Apple or Google Pay, or by mailing us a check. You can also call in with your credit card information at any time: 888-497-0290.

Return & Cancellation Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee. New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made. See our complete return policy for more information at: https://firealarm.com/faq/